INA186A2QDDFRQ1
Product Specifications
INA186A2QDDFRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA186A2QDDFRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA186A2QDDFRQ1: gain of 50 with an enable pin, in the automotive string
The INA186 measures current across a shunt with a common mode range that starts at 0.1 V and runs to 40 V, from a supply of 1.7 V to 5.5 V, and adds an enable pin that puts the output into a high impedance state and drops the supply current when the channel is not being used. The A2 member has a gain of 50 V/V. Offset is 3 microvolts typical and 50 microvolts maximum, drift is 0.05 microvolts per degree typical, and input bias current is 0.5 nA, which is what allows a large shunt to be used for a microamp measurement without the bias current becoming the error.
Common mode rejection is 120 dB minimum and 150 dB typical across the 0.1 V to 40 V window, because the input stage is a zero drift chopper rather than a simple pair. That rejection is what lets the part measure a few milliamps on a 40 V rail while the rail itself moves. Bandwidth falls from about 45 kHz at the lowest gain to 35 kHz at the highest, and the response is slow enough that the enable pin can be used to blank the channel between measurements without a settling penalty on the next reading.
Key data for the INA186A2QDDFRQ1
| Gain | 50 V/V fixed, with 25, 100, 200 and 500 V/V members in the same family |
| Common mode | 0.1 V to 40 V, independent of the 1.7 V to 5.5 V supply, so a 36 V rail is inside the window |
| Offset | 3 microvolts typical and 50 microvolts maximum, drift 0.05 microvolts per degree typical |
| Bias | 0.5 nA typical input bias current, which permits a large shunt for a microamp range measurement |
| Rejection | Common mode rejection 120 dB minimum and 150 dB typical, supply rejection 1 to 10 microvolts per volt |
| Enable | An enable pin drops the supply current and puts the output in a high impedance state on demand |
Body, marking and reel data
| Body | DDF, the thin SOT-23 with eight pins, 3000 pieces on a large reel, 2.3 mm by 2.55 mm body |
| String | The Q1 automotive string is not printed in the industrial INA186 addendum, so the row has to be confirmed |
| Finish | NIPDAU, moisture level 1 with unlimited floor life on the rows the addendum prints |
| Grade | The industrial rows are minus 40 C to 125 C, and the automotive string carries its own qualification record |
Where the low bias current changes the sensor
A current sense amplifier with a bias current of a microamp cannot be used with a 1 ohm shunt when the current being measured is a microamp, because the bias alone would swamp the signal. This part's 0.5 nA of bias current allows a shunt of hundreds of ohms, which turns a microamp of load current into a measurable millivolt. That is the mechanism behind a sleep current measurement in a battery product, a leakage test on a capacitor, or a sensor that sleeps between readings and has to prove its own consumption.
The enable pin pairs with that: a channel that is only read once a second can be switched off in between, which matters when the measuring circuit is powered from the battery it is monitoring. Where a customer is moving a battery product to an automotive platform, the Q1 string carries the qualification and the DDF body carries the footprint. Our power management cross reference lists the family by gain and body, and the supplier quality audit page covers the documents that travel with a Q1 lot.
Buyer questions on the INA186A2QDDFRQ1
Is the Q1 row in the industrial data sheet? No. The industrial INA186 document does not print an automotive addendum row for this string, so the orderable code has to be confirmed with the vendor or through the automotive document before a schedule is set.
Can the enable pin be left floating? It has an internal pull up on the rows that carry the pin, so a circuit that does not use it leaves it open and the channel runs. A channel that must default to off needs the pin driven low.
Why does a 40 V common mode need a 1.7 V supply? The supply only powers the output stage and the chopper. The input stage is a switched capacitor front end that handles the high common mode without a divider, so the supply and the common mode are independent.
Availability and ordering notes
Because the automotive row is not printed in the industrial document, a first order for this string is confirmed rather than assumed, and the confirmation is recorded on the quote. The DDF body is also used by several other members of the family, so a mixed kit is a real risk on a busy line and the marking is the check at goods inward. Where a customer needs the microamp range in a non automotive product, the industrial string in the same body is the cheaper route and the one stop BOM sourcing page covers how the two are quoted side by side.