DRV8908QPWPRQ1
Product Specifications
DRV8908QPWPRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV8908QPWPRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV8908QPWPRQ1: Eight Half Bridges on One SPI Bus for HVAC Flaps and Mirror Motors
DRV8908QPWPRQ1 is an automotive eight channel half bridge driver with SPI configuration and diagnostics in a HTSSOP (PWP) body of 24 pins. It runs from 4.5 V to 32 V with a 40 V absolute maximum, gives each of its eight half bridges 1 A RMS, and reaches 6 A when outputs are paralleled. Configuration and diagnostics run over a 16 bit SPI at 5 MHz with daisy chain support, and the device includes four programmable PWM generators so the host does not have to toggle pins. The parts in this family are pin to pin compatible from four to twelve half bridges, which is why a platform can scale a body controller up or down without a new board.
Order code and package
| Ordering string | DRV8908QPWPRQ1, HTSSOP, large reel |
| Family document | DRV8904-Q1 through DRV8912-Q1, SLVSEC9C, September 2019, revised February 2020 |
| Channel count | eight half bridges, up to four full H bridges |
| Package | HTSSOP (PWP), 24 pins, 7.80 mm by 4.40 mm |
| Qualification | AEC-Q100 grade 1, minus 40 to plus 125 degrees ambient |
| Bus | 16 bit SPI, 5 MHz, daisy chain capable |
| PWM generators | four programmable generators, 8 bit duty resolution |
| Fault pin | nFAULT, open drain, shared across the family |
| Compatible siblings | DRV8904-Q1, DRV8906-Q1, DRV8910-Q1, DRV8912-Q1 |
| Loads | brushed DC motors, stepper motors in sequential or parallel mode, solenoids and LEDs |
Electrical parameters that decide the application
| Supply range | 4.5 to 32 V, absolute maximum 40 V |
| Current per output | 1 A RMS continuous, 6 A maximum with outputs paralleled |
| High side on resistance | 0.75 Ohm typical, 1.1 Ohm maximum at 25 C, 1.5 Ohm at 125 C |
| Low side on resistance | 0.75 Ohm typical, 1.1 Ohm maximum at 25 C, 1.5 Ohm at 125 C |
| Sleep current at 13.5 V | 0.35 uA typical, 1 uA maximum at 25 C, 2 uA at 125 C |
| Turn off time | 200 us to sleep |
| Output slew rate | 0.6 V per us into 27 Ohm, configurable |
| PWM frequency options | 80, 100, 260 and 2000 Hz by register |
| Undervoltage lockout | 4.0 V rising, 4.5 V maximum threshold, 200 mV hysteresis |
| Overvoltage protection | 21 to 25 V rising by default, 32.7 to 35 V with the extended setting |
| Overcurrent trip | 2.3 A maximum, deglitch from 1 us to 40 us by register |
| Open load detection | 2 to 18 mA active, 113 uA passive in the high impedance state |
| Watchdog | SPI watchdog with a programmable timeout |
| Thermal warning and shutdown | warning flag before the shutdown threshold |
| Logic supply | 3 to 5.5 V on VDD, separate from the motor supply |
Family variants and how they differ
| DRV8904-Q1 | four half bridges, same package and pinout |
| DRV8906-Q1 | six half bridges, same package and pinout |
| DRV8908-Q1 | eight half bridges, the part on this page |
| DRV8910-Q1 | ten half bridges, larger package |
| DRV8912-Q1 | twelve half bridges, larger package |
| DRV8873-Q1 | single H bridge with integrated current sense, for one big load |
| What the family shares | SPI map, protection set and the pin order |
| What changes | channel count and the number of PWM generators |
Points to check before this part goes on a BOM
Eight half bridges with SPI diagnostics replace a pile of discrete drivers and a lot of harness. In a body controller the loads are small motors and solenoids that each need a low side or a full bridge, and the failure that hurts is not the driver dying but the controller not knowing which load is open. This device reports an open load per channel, distinguishes a short to ground from a short to the supply, and sets a fault bit without shutting the other channels down, so a mirror motor fault does not take out the HVAC flaps. That granularity is the reason to pay for the SPI part rather than for eight discrete low side switches.
The 1 A RMS figure per output is a thermal statement as much as an electrical one. With 1.5 Ohm per FET at 125 degrees and a 1 A load, one output dissipates about 1.5 W in the low side plus the switching loss, and eight of those at once is 12 W in a 24 pin power package. The on resistance drops to 1.1 Ohm at 25 degrees, so the same load runs cooler in a cold cabin, but the worst case is always the hot board behind a dashboard. Loads that must run together, such as four window motors, need the paralleled outputs at 6 A or a different driver, and the thermal calculation on the actual board is what decides which.
Parallel mode is a register setting rather than a wiring trick. Two half bridges can be tied to the same load and driven together, which halves the on resistance and doubles the current capability, and the device checks that the two channels report the same state so a mismatch is flagged. That is what lets one part cover a 1 A flap motor and a 5 A seat pump on the same board. The catch is that the paralleled pair has to be wired symmetrically, because a difference in trace resistance between the two outputs turns into a current imbalance that the open load and overcurrent thresholds cannot see until one of them trips.
The diagnostics are only as good as the thresholds set for the load. Open load detection pushes a small current into the load and measures the voltage, which works when the load is a motor winding of a few ohms and fails when the load is an LED string with a series resistor or a solenoid with a diode across it. The passive open load mode works in the high impedance state with 113 uA and is the setting for loads that must not be energised during the test. Getting these two modes right at the bench saves a great deal of time in the vehicle, because a false open load flag on a good motor sends a technician to replace a part that works.
Reading the fault registers in the right order
The diagnostic registers latch, and the order in which they are read decides whether the record makes sense. A short to ground on one output usually sets the overcurrent bit, then the thermal warning bit, then the global fault bit, within a few milliseconds. A controller that reads only the global fault sees an overcurrent and misses that the channel was already hot, which sends the investigation to the wrong place. Reading the per channel fault register first, then the thermal status, then clearing the latches, gives a record that can be compared across units. The same order matters for an open load flag, because a channel that is switched off reports an open load unless the diagnostic is armed only while the output is driven.
Where this order code fits
HVAC flap and blend door motors, mirror adjust and fold, multiple solenoids, LED groups and small brushed motors in a body controller. A platform that needs four, six, eight, ten or twelve outputs uses the same footprint across the family. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can the outputs drive LEDs with dimming? Yes, the PWM generators give 8 bit duty control per channel, and the frequency options cover both flicker free dimming and motor drive.
Does the SPI bus have to be isolated? No, it is a 3.3 V or 5 V logic interface referenced to the controller ground. What matters is the watchdog, which resets the outputs if the bus goes quiet.
What happens on an overcurrent event? The channel is disabled, the fault bit is set, and the deglitch time decides how long the event must last. Above 28 V the deglitch has to be set to 1 us by the data sheet note.
Can two outputs be paralleled for a bigger motor? Yes, in parallel mode with a symmetric wiring, which gives 6 A maximum and half the on resistance per channel pair.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the One Stop BOM Sourcing page sets out the checks that keep a substitute from failing on the bench.