- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV8245PQPWPRQ1: the same 32 A bridge with an SPI port and an external logic rail
The DRV8245PQPWPRQ1 is the SPI member of the 32 A DRV824x-Q1 pair, in the 28-pin HTSSOP body with 40 mOhm of combined on resistance. It runs from 4.5 V to 35 V with a 40 V absolute maximum, drives up to 32 A, and reports current on IPROPI from a high-side mirror the same way the hardware variant does.
The P means the logic rail comes from outside the part. On a module that already has a 3.3 V or 5 V supply, the SPI lines sit at the controller level, so no level translation is needed and the timing margins are set by the board rather than by an internal regulator. The S variant of the same die makes its own rail, and the H variant has no port at all.
What the port buys is visibility. Slew rate, current limit, fault reaction, spread spectrum and the diagnostic thresholds become register fields instead of resistors, and the fault registers say which protection tripped and on which half bridge. On a load that has several failure modes, or on a platform that has to be reconfigured for different vehicle variants, that is worth the extra pin count.
Key data for the DRV8245PQPWPRQ1
| Supply | 4.5 V to 35 V operating, 40 V absolute maximum on VM |
| On resistance | 40 mOhm high side plus low side in HTSSOP, 32 mOhm in VQFN-HR |
| Current | 32 A maximum output, high-side mirror sense on IPROPI |
| Interface | SPI with an externally supplied logic rail, plus nFAULT |
| Configuration | Slew rate, current limit, fault reaction and diagnostics set in registers |
| Diagnostics | On and off state load diagnostics, VM monitoring, overcurrent, overtemperature |
| Qualification | AEC-Q100 grade 1, minus 40 C to plus 125 C ambient, functional safety capable |
Body, packing and marking data
| Body | 28-pin HTSSOP with exposed pad, the PWP body, 9.7 mm by 4.4 mm |
| Carrier | 2500 pieces on a large tape and reel, 330 mm reel, 16 mm tape |
| Finish | Nickel palladium gold, moisture level 3, 168 hour floor life at 260 C |
| Marking | DRV8245P plus the lot and date code on the reel label |
Reading the code before you buy it
DRV8245PQPWPRQ1 reads as DRV8245, P, PWP and RQ1. The letter after the current number is the interface and the logic supply arrangement, not a revision, so it is the field that decides whether the module boots at all. A board laid out for the H variant has the pins that the P variant uses as SPI lines tied to resistors, and the part will answer on a bus that nobody is driving.
The register map is shared across the three current members, so a platform can move from 12 A to 32 A without changing the controller software. That is the practical value of the family: one code base, one board, three power levels, and a diagnostics path that does not change when the load changes.
Two order code details are worth checking before a purchase order goes out. The reel count and the moisture level on this body are printed on separate rows for the plain string and for the .A string, so the two rows are not the same part under two names. And the RQ1 suffix is the automotive grade, which cannot be substituted with an industrial string even when the electrical table looks identical.
The register map is where the money is on this part. A single fault register separates an overcurrent on the high side from an overcurrent on the low side, and a status register reports undervoltage, overtemperature warning and charge pump faults before any of them become a shutdown. A module that reads those bits can log a degradation and schedule a service instead of failing at the roadside.
Configuration through the port also changes what a bill of materials has to carry. Instead of a resistor per setting, one part number covers a range of current limits, slew rates and fault reactions, and the difference is written at end of line. On a platform with several variants, that removes the variant from the hardware and puts it where a change costs nothing but a programming step.
Where the SPI member earns its place
Multi-load modules are the first case. A door module that drives a window lift, a mirror fold and a lock motor from three bridges needs to know which one failed, and the fault registers answer that without three separate fault wires running back to the controller.
Platform modules are the second case. When the same board is built for three vehicle variants with different loads, the register map lets the module be configured at end of line rather than by fitting different resistors. The bill of materials stays one part number, and the variant lives in software.
High current actuators that need a soft shutdown are the third. The SPI port lets the slew rate and the fault reaction be changed while the load is running, which is how a module handles a stall without a hard current chop that trips the supply monitoring of the rest of the vehicle. Buyers moving this class of part across a platform can compare the members on the power management cross reference page.
Questions we get on this code
The first question is whether the SPI port is needed if the load is simple. It is not, and the H variant is cheaper and has fewer ways to fail. The port pays for itself when the module has more than one bridge or more than one variant.
The second question is about the logic rail voltage. The P variant follows whatever the board supplies, so a 5 V controller and a 3.3 V controller can share the same part, but the register map is the same in both cases and the timing has to be checked at the lower level.
The third question is what the diagnostic registers actually report. They separate an open load from a short to ground and from a short to battery, in both the on and the off state, which is four failure classes from one bridge. The thresholds are register fields, so the same part can be tuned for a 2 A load and a 20 A load without a hardware change.
The fourth question is what the port does for the incoming test. A module that can read the fault registers can run a self test at end of line, driving each bridge into a known load and confirming that the diagnostics see it. That replaces a functional test fixture with a few register reads, which is a real saving on a high volume line.
The fifth question is about conformity of supply. When a module is qualified around one of these parts, a substitute that is pin compatible but not register compatible is not a substitute. The verification route is on the how to verify a drop in replacement page.