DRV5056A3QDBZR
Product Specifications
DRV5056A3QDBZR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV5056A3QDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV5056A3QDBZR: a unipolar linear Hall sensor with a 0.6 V offset
The DRV5056A3QDBZR is a ratiometric linear Hall sensor that responds to one pole only, and it starts its output at 0.6 V rather than at half the supply. That single change is the point of the DRV5056 family: on a south pole sensor, half of the output range that a bipolar part spends on the negative direction is now available for the positive swing, so the useful resolution goes up for the same converter.
The A3 option gives 50 mV per mT at 5 V with a linear range of about 79 mT, which suits a magnet that produces 30 to 60 mT at the working gap. The A in the code means the sensitivity is temperature compensated at 0.12 percent per degree, which is the right choice for a ferrite or a bonded magnet whose field falls as it warms.
Everything else follows the family: 3.3 V or 5 V supply, a 20 kHz sensing bandwidth, 6 mA typical supply current and a quiescent output of 0.535 V to 0.665 V at zero field. The body is the SOT-23 and the packing on this string is 3000 pieces on a reel.
Key data for the DRV5056A3QDBZR
| Output | Analog, ratiometric, 0.6 V at zero field, rises with a south pole |
| Sensitivity | 50 mV per mT at 5 V typical on the A3 option |
| Linear range | About 79 mT above the zero point before the output clips |
| Quiescent output | 0.535 V to 0.665 V at zero field, 0.6 V nominal |
| Compensation | 0.12 percent per degree of magnet drift, A version only |
| Bandwidth and current | 20 kHz sensing bandwidth, 6 mA typical and 10 mA maximum supply current |
| Supply | 3.3 V or 5 V, ratiometric to the rail |
Body, packing and marking data
| Body | SOT-23, three pins, DBZ outline |
| Packing | 3000 pieces on a reel, printed as an ammo carrier on the current addendum row |
| Finish | Tin lead finish, moisture level 2 with a one year floor life |
| Marking | 56A3 on the body, which identifies the A3 die |
Unipolar means one direction only
A north pole does nothing to this part. The output sits at its quiescent 0.6 V when no field is present, rises as a south pole approaches, and stays at the quiescent level for the opposite pole. That is not a fault, it is the reason the part exists: on a mechanism where the magnet only ever approaches from one side, half of a bipolar sensor's range would be permanently unused.
The trade is that the sensor cannot tell a north pole from no magnet at all. If a diagnostic has to distinguish a missing magnet from a reversed one, this family is the wrong choice, and the bipolar DRV5055 with its half supply offset is the right one.
The second trade is the offset tolerance. The quiescent window of 0.535 V to 0.665 V is about 20 percent wide, which dominates the error at the low end of the travel. A controller that calibrates the zero at every power up removes it, and one that trusts the nominal figure carries it into every reading.
Where the A3 setting is the right one
Hydraulic spool position, suspension travel, and any actuator with a 40 to 60 mT swing at the sensor face are the natural applications for 50 mV per mT. The unipolar response also suits an arrangement where the magnet is on a piston that only ever comes towards the sensor from one side.
When a program is qualifying a second source, the how to verify a drop in replacement page covers the offset and slope checks that separate an A3 from an A6, and the pin to pin cross reference page lists what has to match when the body changes.
Questions we get on this code
Can a unipolar part be used where the magnet passes in both directions? It can, but only one direction produces a signal, so a mechanism that overshoots and comes back reads the same field twice and the controller sees a fold in the position curve. Use a bipolar part wherever the travel crosses the zero field point.
Why is the supply current 6 mA when the sensor is analog and simple? Because the chopper amplifier runs continuously and the output stage drives the load. The 10 mA maximum is the number to use for the rail budget, and on a system with several sensors the total is what decides the regulator size rather than the typical figure.
One more practical note. The 0.6 V quiescent point sits close to the bottom rail, so a shorted output reads about the same as a magnet at zero field. A controller that checks for a rail level as a fault has to use the top of the range or add a second test, otherwise a dead channel looks like a parked mechanism.