DRV5055Z4QDBZR
Product Specifications
DRV5055Z4QDBZR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV5055Z4QDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV5055Z4QDBZR: the wide range linear sensor without compensation
The DRV5055Z4QDBZR is the least sensitive member of the DRV5055 group at 12.5 mV per mT, with a linear range of about 169 mT at 5 V. The Z in the code means no magnet temperature compensation, so the sensitivity stays fixed as the temperature moves, and that is the right behaviour when the field itself is the measured quantity rather than a proxy for position.
A wide range part is used where the magnet is strong or the gap is small and a sensitive part would clip. A 100 mT field at 12.5 mV per mT moves the output by 1.25 V, which is a good signal on a 5 V rail, where the 100 mV per mT option would have saturated long before that field arrived.
The ratiometric architecture is common to the family: the quiescent output is half the supply, so a 5 V part sits at 2.5 V and a 3.3 V part at 1.65 V, and the reading is taken against the same rail that feeds the part.
Key data for the DRV5055Z4QDBZR
| Output | Analog, ratiometric, quiescent at half the supply |
| Sensitivity | 12.5 mV per mT at 5 V, 7.5 mV per mT at 3.3 V |
| Linear range | About 169 mT at 5 V, the widest of the group |
| Compensation | None on the Z version, so the sensitivity does not track magnet drift |
| Bandwidth | 20 kHz sensing bandwidth |
| Supply | 3.3 V or 5 V, 3 mA typical at 5 V |
| Temperature | Minus 40 C to plus 125 C on the Q grade |
Body, packing and marking data
| Body | SOT-23, three pins, DBZ outline |
| Packing | 3000 pieces on a large reel on the R suffix |
| Finish | Tin lead finish, moisture level 2 at 260 C with a one year floor life |
| Marking | 55Z4 on the body, which is the only visible difference from an A4 part |
A and Z are one letter apart
DRV5055Z4 and DRV5055A4 share the same 12.5 mV per mT at 5 V and the same 169 mT range at 25 C, and they differ only in the temperature behaviour. The A part raises its sensitivity by about 0.12 percent per degree to offset a magnet that weakens as it warms. The Z part does not, so the reading falls with temperature at whatever rate the magnet falls.
Which one is correct depends on what the measurement is for. On a position sensor with a ferrite or a bonded magnet, the A part gives a reading that stays calibrated over temperature. On a field measurement where the magnet is the object under test, or where the system calibrates its own zero and gain at every start up, the Z part is simpler and does not add an assumption about the magnet.
The addendum prints the Z4QDBZR row as active and the A revision row of the same string as obsolete, so a reorder should name the active row. The marking on the body is the only way to tell the two dies apart once the reel is off.
Where a 169 mT range is needed
Current sensing on a busbar, magnetic field mapping, and position on a mechanism with a large magnet and a short gap are the applications that need this range. It also appears as a general purpose field probe in test fixtures, where a saturated reading is worse than a coarse one.
Where a substitute has to be found for a discontinued linear sensor, the obsolete part cross reference hub is the place to start, and the how to verify a drop in replacement page covers the range and slope checks before a Z part replaces an A part.
Questions we get on this code
Is 12.5 mV per mT enough resolution for a position reading? On a 12 bit converter over 3.3 V each count is 0.8 mV, which is 0.06 mT, so the resolution is fine; the limit is noise rather than the converter. Averaging a few samples recovers the last digit, which is why this part is usually read with a short filter rather than a single conversion.
Why is the quiescent output half the supply rather than a fixed voltage? Because the whole signal chain is ratiometric: an ADC that references the same rail cancels the supply tolerance, and a sensor that sits at half the rail lets the output swing equally in both directions. A fixed quiescent voltage would waste half the range on a 3.3 V system.
The last thing to check on a wide range part is the magnet itself. At 169 mT of range, a small disc magnet at 3 mm may only produce 20 mT, which is 250 mV of swing on a 5 V rail, and that is a small signal for a part chosen for its wide range. The range and the magnet have to be chosen together, not one after the other.