DRV5055A1QDBZR
Product Specifications
DRV5055A1QDBZR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV5055A1QDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV5055A1QDBZR: A Ratiometric Hall Sensor That Reads Half the Rail at Zero Field
DRV5055A1QDBZR is a ratiometric linear Hall effect sensor in a SOT-23 (DBZ) body of 3 pins. It runs from a 3.3 V or 5 V rail, sits at half the rail with no field present, and swings 100 mV per millitesla, so a plus or minus 21 mT field covers most of the output range. The A letter adds compensation for the way a magnet loses strength as it warms, the sensing bandwidth is 20 kHz, and the three pin SOT-23 needs nothing but a supply and a decoupling capacitor.
Order code and package
| Ordering string | DRV5055A1QDBZR |
| Family document | DRV5055, SBAS640C, revised June 2026 |
| Package | SOT-23 (DBZ), 3 pins |
| Reel and packing | 3000 pieces on a large reel, tin lead finish |
| Moisture level | Level 2, 260 C peak, one year floor life |
| Body marking | 55A1 |
| Temperature range | minus 40 to plus 125 degrees |
| Through hole sibling | DRV5055A1QLPG in TO-92, 1000 pieces in bulk |
| Sensitivity option | A1, 100 mV per mT at 5 V, plus or minus 21 mT of range |
| Temperature compensation | Included on the A options, absent on the Z options |
| Offset at zero field | Half of VCC by architecture, 2.5 V on a 5 V rail |
Electrical parameters that decide the application
| Supply range | 3.0 to 3.63 V and 4.5 to 5.5 V, two specified windows |
| Supply current | 3 mA typical and 4 mA maximum at 5 V, lower at 3.3 V |
| Sensitivity at 5 V | 100 mV per mT typical, 95 to 105 over temperature |
| Sensitivity at 3.3 V | 60 mV per mT typical, 57 to 63 |
| Quiescent output | 2.50 V typical at 5 V, 2.43 to 2.57 over temperature |
| Field range | Plus or minus 21 mT for the A1 option at 5 V |
| Sensing bandwidth | 20 kHz |
| Propagation delay | 10 us from a change in field to a change in output |
| Output drive | Plus or minus 1 mA |
| Noise | 6 mV peak to peak at the output for the A1 option with a 5 V rail |
| Lifetime drift | Under 0.5 per cent of the quiescent voltage over 1000 hours at high temperature |
| Ratiometry error | About 0.2 per cent per degree on the quiescent point |
Family variants and how they differ
| DRV5055A1 | 100 mV per mT and plus or minus 21 mT, the highest sensitivity with compensation |
| DRV5055A2 | 50 mV per mT and plus or minus 42 mT |
| DRV5055A3 | 25 mV per mT and plus or minus 85 mT |
| DRV5055A4 | 12.5 mV per mT and plus or minus 169 mT |
| DRV5055A8 | 66 mV per mT and plus or minus 32.5 mT, the option for a mid range field |
| DRV5055Z1 to Z4 | The same sensitivities without magnet temperature compensation |
| A against Z | The A options flatten the drift of a neodymium magnet, the Z options leave the output uncompensated |
| Package choice | SOT-23 for surface mount, TO-92 for a leaded assembly |
Points to check before this part goes on a BOM
Ratiometric means the output is a fraction of the supply, not a fixed voltage. With 5 V on the rail the zero field point sits at 2.5 V and the sensitivity is 100 mV per mT, and with 3.3 V the same field gives 60 mV per mT around 1.65 V. An ADC that uses the same rail as its reference therefore cancels the supply tolerance completely, which is the reason this architecture is chosen over the fixed output sensors in the same catalogue.
The A letter is a magnet compensation, not a sensor calibration. Neodymium magnets lose roughly a tenth of their strength between room temperature and 125 degrees, and the A options bend the sensitivity curve to follow that loss so that a position reading stays put as the mechanism warms. The Z options leave the output uncompensated, which is correct when the field comes from a coil or from a magnet that is held at a stable temperature.
The field range and the sensitivity are the same choice seen twice. The A1 option reads plus or minus 21 mT at 100 mV per mT and the A4 option reads plus or minus 169 mT at 12.5 mV per mT, so a mechanism with a large magnet travel and a coarse requirement takes the low sensitivity option and a mechanism with a small travel and a fine requirement takes the high one. Choosing the most sensitive option for a large field simply clips.
The 20 kHz bandwidth is far above what a mechanical position needs, which is what allows the part to be used for a current sensor built around a coil or for a rotation counter. The 10 us of propagation delay then becomes the limit on how fast a control loop can close, and a motor commutation scheme that needs the field reading within a few microseconds has to account for it.
The output drives plus or minus 1 mA, which is enough for a short trace into an ADC and not enough for a long cable. A sensor mounted on a separate board through a harness needs a buffer or a lower impedance path, and the RC filter that removes the 6 mV of noise has to be sized against the 1 mA drive rather than against a low impedance source.
Position sensing with a compensated sensor
A throttle pedal, a valve stem or a joystick measures a magnet moving over a few millimetres, and the field at the sensor is a few milliteslas at most. The A1 option covers that with 100 mV per mT, so a 5 mm travel that changes the field by 4 mT produces 400 mV of swing, which is a comfortable signal for a 12 bit converter working from the same 5 V rail.
Because the output is ratiometric, the converter can take its reference from the sensor rail and the reading becomes independent of whether that rail is 4.9 V or 5.1 V. The remaining error is the offset window and the sensitivity window, both of which are specified over the full temperature range, so a production line can either calibrate each unit or accept the spread.
Where the uncompensated option is the right one
A current sensor that measures the field of a coil, or a rotation counter that reads a steel gear, does not see a magnet that drifts with temperature. In those cases the compensation of the A options actually introduces an error, because the field being measured does not fall with temperature while the sensor assumes it does. The Z options exist for exactly that case.
The difference between the two is a few per cent of reading over the temperature range, which matters for a position measurement and does not matter for a switch. A board that only needs a threshold crossing can use either option and set the threshold in the middle of the travel.
Where this order code fits
The part fits a position measurement on a 3.3 V or 5 V rail where the converter shares the sensor supply as its reference and the magnet is a neodymium one that warms up with the mechanism. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.
Questions buyers ask
What is the output at zero field? Half of the supply, 2.5 V on a 5 V rail and 1.65 V on a 3.3 V rail, with a window of about 70 mV around that point over temperature. The output then moves 100 mV per mT at 5 V in the direction set by the pole.
Does the sensitivity change with the supply? Yes, and that is the point of the ratiometric architecture. Sensitivity falls with the rail, 100 mV per mT at 5 V and 60 mV per mT at 3.3 V, so an ADC referenced to the same rail reads the same field regardless of the exact supply voltage.
When should the Z option be used instead of the A option? When the field does not come from a magnet that changes strength with temperature, for example a coil or a steel target. The A option assumes a neodymium magnet and would over correct in those cases.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.