DRV5053VAQDBZR
Product Specifications
DRV5053VAQDBZR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV5053VAQDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV5053VAQDBZR: A Bipolar Hall Sensor With 90 mV per mT and a 38 V Supply Ceiling
DRV5053VAQDBZR is an analog bipolar Hall effect sensor in a SOT-23 (DBZ) body of 3 pins. It puts out 1.02 V with no field present and swings about 90 mV for every millitesla, in a direction that depends on the pole, so a single part measures both north and south. The supply accepts anything from 2.5 V to 38 V with no regulator, reverse polarity to minus 22 V is tolerated, and the whole sensor sits in a three pin SOT-23 that is 2.92 mm long.
Order code and package
| Ordering string | DRV5053VAQDBZR |
| Family document | DRV5053, SLIS153D, revised February 2023 |
| Package | SOT-23 (DBZ), 3 pins, 2.92 mm by 1.30 mm body, 2.92 mm by 2.37 mm including leads |
| Reel and packing | 3000 pieces on a large reel |
| Lead finish | Tin on the plain row, NiPdAu with tin on the A row |
| Moisture level | Not applicable on the plain row, Level 1 unlimited on the A row |
| Body marking | ALVA and 1M42 |
| Temperature range | minus 40 to plus 125 degrees |
| Through hole sibling | DRV5053VAQLPG in TO-92, 1000 pieces in bulk |
| Sensitivity letter | V, the 90 mV per mT option, the most sensitive of the family |
| Output | Analog, 0.2 V to about 1.8 V on a 3.3 V supply |
Electrical parameters that decide the application
| Supply range | 2.5 to 38 V |
| Reverse supply | Minus 22 V tolerated |
| Supply current | 2.7 mA typical at 25 C, 3.6 mA maximum at 125 C |
| Quiescent output | 1.02 V typical at zero field, 0.9 V to 1.15 V over temperature |
| Sensitivity | Minus 90 mV per mT typical, window from minus 140 to minus 45 |
| Sensitivity drift | Within 10 per cent over the full temperature range |
| Output saturation | 0.2 V at the low end, near the supply at the high end |
| Output drive | 300 uA of source current, 2.3 mA of sink current |
| Power on time | 35 us typical and 50 us maximum |
| Output delay | 13 us typical and 25 us maximum |
| Output noise | 44 mV peak to peak at 3.3 V with a 10 kΩ load and 50 pF |
| Saturation field | Around 9 mT at 3.3 V, beyond which the output no longer follows the field |
| Overcurrent protection | Both source and sink outputs are limited internally |
Family variants and how they differ
| DRV5053OA | 11 mV per mT, the widest field range and the least sensitive option |
| DRV5053PA | 23 mV per mT |
| DRV5053RA | 45 mV per mT |
| DRV5053VA | 90 mV per mT, the option on this page |
| DRV5053CA | Plus 23 mV per mT, the opposite slope for a sensor mounted on the other side of the magnet |
| DRV5053EA | Plus 45 mV per mT, the positive slope partner of the R option |
| Polarity | A negative slope means a north pole facing the marked side drives the output down |
| Supply independence | Sensitivity is quoted at 3.3 V and does not scale with the rail |
Points to check before this part goes on a BOM
The output is not ratiometric, which separates this part from the sensors that divide the supply. Sensitivity is quoted as a fixed number of millivolts per millitesla at 3.3 V, and the quiescent output sits at about 1.02 V regardless of the rail, so a 24 V supply runs the same signal swing as a 3.3 V one. That is convenient for a wide voltage system and awkward for an ADC that expects a ratiometric reading.
The quiescent output moves with temperature, and the specification gives a 250 mV window over the full range rather than a single value. A board that treats 1.02 V as a fixed zero point inherits that drift as an offset error, and a board that calibrates at one temperature and runs at another sees it as a position shift. The sensitivity drift is held within 10 per cent, so the gain is far more stable than the offset.
The saturation field is the limit that decides the magnet. At 3.3 V the device stops following the field somewhere near 9 mT, so a magnet pair chosen for a 20 mT swing at the sensor will clip at both ends and the useful travel is lost. A weaker magnet, or a larger air gap, keeps the swing inside the linear window, and the 90 mV per mT option is the one to choose when the field is small and the resolution matters more than the range.
Reverse polarity protection to minus 22 V is unusual in a three pin analog sensor and it changes what the board has to carry. A connector that can be plugged in backwards, or a harness that is wired wrong at the factory, will not destroy the part, and the same applies to the output pin, which is protected against a short to the supply. The protection is not a substitute for a series resistor on a long harness, because a transient above 38 V still exceeds the absolute maximum.
The three pin body has no programming interface and no memory, so every unit is used as it comes. That means the offset window and the sensitivity window are the engineering budget: a position measurement that needs one per cent of full scale has to either calibrate each assembly or accept the spread of the two windows. For a switch, where the threshold is set by a comparator and the exact crossing point does not matter, the spread costs nothing.
Where a 90 mV per mT sensor is the right choice
A linear Hall sensor with this sensitivity is used where the magnet is small and the travel is a few millimetres: a valve position, a throttle pedal, a joystick, a door latch or a liquid level float. The field at the sensor in those mechanisms is often below 10 mT, which is exactly the region where the 45 mV option runs out of resolution and the 90 mV option still gives a usable slope.
Mounted on the other side of the magnet, the same part reads the opposite slope, which is why the family carries positive slope options as well. Buying the C or E letter instead of turning the board over is sometimes the cheaper change, but the mechanical drawing usually decides which face of the package the magnet can see.
Reading the output into an ADC
The output can source 300 uA and sink 2.3 mA, so it drives a high impedance ADC input directly and needs a buffer only when the sampling capacitor is large or the sample rate is high. An RC filter at the pin reduces the 44 mV of output noise, and because the signal bandwidth is limited, a time constant of a few hundred microseconds costs nothing in response time.
The 13 us of output delay and the 35 us of power on time set how fast the sensor can be polled after the rail comes up. A system that enables the supply and reads the ADC within 10 us reads a value that has not settled, and a system that samples faster than the delay simply repeats the same reading.
Where this order code fits
The part fits a position or proximity measurement where the field at the sensor is small, the supply may be anything from 3.3 V to 24 V, and a three pin analog output is all the interface the controller wants. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the How to Verify a Drop in Replacement page.
Questions buyers ask
Does the output scale with the supply voltage? No. Sensitivity and quiescent output are fixed numbers quoted at 3.3 V, so the same magnet gives the same swing on a 5 V or a 24 V rail. That is convenient on a wide voltage system but it means the ADC reference has to be independent of the sensor rail.
Which pole drives the output up? The V option has a negative slope, so a north pole facing the marked side drives the output down and a south pole drives it up. The C and E options have positive slopes for the mirrored mounting.
What happens beyond the saturation field? The output stops following the field at around 9 mT at 3.3 V and sits near the rail. A magnet chosen for a larger swing clips at both ends, so the linear travel has to be kept inside the window or a less sensitive option has to be used.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.