DRV5053RAQDBZR

Brand: Texas Instruments
Texas Instruments DRV5053RAQDBZR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

DRV5053RAQDBZR — Power Management & Signal Chain | Superb Automation

DRV5053RAQDBZR

Texas Instruments — Power Management & Signal Chain

Product Overview

The DRV5053RAQDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

DRV5053RAQDBZR: A 45 mV per mT Analogue Hall Sensor That Reports Field Strength, Not Just Presence

DRV5053RAQDBZR is a chopper stabilised analogue bipolar Hall effect sensor with a rail referenced output in a SOT-23 (DBZ) body of 3 pins. It runs from 2.5 V to 38 V, puts out 1 V with no field present, and moves 45 mV for every millitesla in the RA option, so the output tells a controller not only that a magnet is near but how near. The output window is 0.2 V to about 1.8 V, which leaves headroom at both ends for the amplifier and lets the part work from the same 3.3 V rail as the converter that reads it. Sensitivity is held to plus or minus 10 per cent over temperature, and that is what makes a linear position measurement possible without a per unit calibration table.

Order code and package

Ordering stringDRV5053RAQDBZR, SOT-23, large reel
Family documentDRV5053, SLIS153D, May 2014, revised February 2023
Sensitivity codeRA, minus 45 mV per mT, output falls as a south pole approaches
PackageSOT-23 (DBZ), 3 pins, 2.92 mm by 1.30 mm
Ambient rangeminus 40 to plus 125 degrees, Q grade
Junction rangeminus 40 to plus 150 degrees
Storage rangeminus 65 to plus 150 degrees
PinsVCC, OUT, GND
Output drive2.3 mA sink, 300 uA source
Other sensitivity codesOA, PA, VA, CA and EA, from 11 to 90 mV per mT

Electrical parameters that decide the application

Supply range2.5 to 38 V, no external regulator required
Absolute maximum supply40 V, reverse to minus 22 V
Quiescent output at zero field1 V typical, the reference point of the transfer curve
Output window0.2 V to approximately 1.8 V
Sensitivity, RA optionminus 45 mV per mT, tolerance plus or minus 10 per cent
Sensitivity over temperatureplus or minus 10 per cent across the full range
Output sink capability2.3 mA
Output source capability300 uA
Power on time35 us
Output noisethe data sheet gives the spectral density in the typical characteristics, which sets the resolution floor after averaging
Reverse supply protectionminus 22 V, tested to minus 20 V
Load dumpsurvives 40 V
ESD, human body modelplus or minus 2500 V
ESD, charged device modelplus or minus 500 V

Family variants and how they differ

DRV5053OA11 mV per mT, the widest range, for a strong magnet and coarse position
DRV5053PA23 mV per mT
DRV5053RA45 mV per mT, the part on this page
DRV5053VA90 mV per mT, the most sensitive, for a small magnet and short travel
DRV5053CA and EApositive slope versions, output rises with a south pole
DRV5023digital switch, no analogue information
DRV5013digital latch, no analogue information
What the code changesonly the slope and the sensitivity, the pins and the supply behave the same

Points to check before this part goes on a BOM

A linear sensor turns a mechanical tolerance problem into a calibration problem, and that is usually cheaper. With a switch, the mounting has to place the magnet inside a narrow window at every unit, and the window is set by the trip point spread. With this part, the output is proportional to the field, so a controller can read the actual position and either correct the offset in firmware or report it. The cost is an analogue to digital converter channel and a noise budget, which on a modern microcontroller is usually already paid for. The 45 mV per mT slope with a 10 bit converter over a 3.3 V range gives about 3.2 mV per count, which is 0.07 mT per count before averaging.

The 1 V quiescent point is what makes the output bipolar on a single supply. With no field the output sits at 1 V, a south pole pulls it down toward 0.2 V and a north pole pushes it up toward 1.8 V, so the sign of the difference from 1 V carries the field direction. The two clamps are not symmetrical in current: the output can sink 2.3 mA but only source 300 uA, so a load that pulls the output up, such as a resistor to the supply, has to be sized for the source limit. Driving an ADC input directly is fine because the input is high impedance, but adding a series resistor for protection above a few hundred ohms starts to shift the reading.

Sensitivity tolerance is the specification that decides whether a per unit calibration is needed. The part is specified at plus or minus 10 per cent over temperature, and the room temperature spread between units is inside that band, so two sensors in the same batch can differ by 20 per cent at the extremes of the distribution. For a go or no go decision that does not matter. For a position readout that has to be accurate to a fraction of a millimetre, it does, and the usual answer is a two point calibration at end of line: one reading with the target at zero and one at full travel, which solves both the slope and the offset per unit.

The supply range is the feature that saves a regulator. Because the part works from 2.5 V to 38 V, it can hang directly on a 24 V industrial rail with only a bypass capacitor and a series resistor for the output, which is what a machine builder wants on a sensor board that already has a 24 V bus. Reverse supply protection to minus 22 V and load dump survival to 40 V cover the common wiring errors on that bus. The output still needs a series resistor into the controller, because the output pin is only rated for 38 V and a fault on the controller side could otherwise pull the sensor output above its limit.

Reading the output with a converter that shares the supply

When the sensor and the converter run from the same 3.3 V rail, the output window of 0.2 V to 1.8 V sits comfortably inside the converter range, and no divider is needed. The output impedance is low enough to drive a successive approximation input directly through a 1 kOhm series resistor, which is there for protection rather than for filtering. A 100 nF capacitor from the output to ground with that resistor forms a filter at about 1.6 kHz, which removes switching noise from a motor driver on the same board without slowing a mechanical measurement that moves in milliseconds. If the sensor runs from 24 V and the converter from 3.3 V, the output has to be divided down, and the divider then loads the 300 uA source capability of the output, so the resistor values have to stay in the tens of kilohms rather than the hundreds.

Where this order code fits

Linear position on a valve stem, pedal or actuator, current sensing through a magnetic concentrator, and any place where the distance to the magnet matters. Teams replacing a potentiometer start here because there is no wiper to wear out. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.

Questions buyers ask

Can it measure a static field with no movement? Yes, the output follows the field continuously, so it measures absolute position as long as the magnet is present.

What resolution is realistic? About 0.07 mT per count with a 10 bit converter before averaging, which on a 5 mm travel with a 30 mT swing is roughly 10 um per count.

Does the output need a buffer before an ADC? Not for a high impedance converter input, but the 300 uA source limit means a low value pull up or a divider will load the output and shift the reading.

Is the CA code simply the RA code inverted? It is a different slope, positive instead of negative, with the same magnitude class, so the output rises as the south pole approaches.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.