DRV5053EAQDBZR
Product Specifications
DRV5053EAQDBZR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV5053EAQDBZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV5053EAQDBZR: a positive slope analog Hall sensor at 45 mV per mT
The DRV5053EAQDBZR is an analog Hall sensor in the SOT-23 body with a sensitivity of plus 45 mV per mT and a quiescent output of 1 V at zero field. Plus means the output rises when a south pole approaches the marked face, and falls when a north pole does, which is the opposite of the RA and VA options in the same family.
The output swings between 0.2 V and about 1.8 V on a 2.5 V to 38 V supply, and the part is chopper stabilised so its sensitivity holds within 10 percent over the full temperature range. Bandwidth is 1.8 kHz, power-on time is 35 us, and the output stage can sink 2.3 mA and source 300 uA, which is enough to drive an ADC input through a short trace.
Choosing between the six sensitivity options is a question of the field the magnet produces. At 45 mV per mT a 10 mT field moves the output 450 mV, which is a comfortable signal for a 12 bit converter; at 90 mV per mT the same field would saturate the output well before the magnet reaches its closest approach.
Key data for the DRV5053EAQDBZR
| Output | Analog, 0.2 V to about 1.8 V, 1 V at zero field |
| Sensitivity | Plus 45 mV per mT, positive slope with a south pole at the marked face |
| Accuracy | Within 10 percent over the full temperature range |
| Bandwidth | 1.8 kHz on the analog output |
| Supply | 2.5 V to 38 V, no regulator, reverse protection to 22 V |
| Supply current | 2.7 mA typical at 25 C, rising to 3.0 mA typical and 3.6 mA maximum at 125 C |
| Temperature | Minus 40 C to plus 125 C on the Q grade |
Body, packing and marking data
| Body | SOT-23, three pins, DBZ outline, 2.92 mm by 1.30 mm |
| Packing | 3000 pieces on a large reel on the R suffix |
| Finish | Tin lead finish on the published rows, moisture level 1 at 260 C |
| Marking | ALEA and 1LZ2 on the body, which is how the EA die is identified |
Reading the string and the two revisions
DRV5053 is the family, EA is the positive 45 mV per mT option, Q is the temperature grade, DBZ is the SOT-23 and R is the 3000 piece reel. The same code with T is a 250 piece reel and with LPG is the TO-92 body, so the last three fields decide packing and body rather than behaviour.
On the addendum this exact string is printed twice, once as active and once as the A revision with an obsolete status. The two rows carry the same body, the same reel and the same temperature range, so the difference is in the marking and the material declaration rather than in the part. A bill of materials that names the obsolete row should be updated at the next revision rather than carried forward.
The second thing to check is the slope sign. A board brought up with an RA part and moved to an EA part will read the field upside down, and the symptom is a position reading that runs the wrong way rather than a dead channel. The fix is in the controller's sign convention, not in the hardware.
Where a positive slope analog part is used
Throttle and pedal position, valve lift, tilt and weight measurement, and any assembly where the magnet approaches from the south side of the package are the natural applications. The positive slope also matters in a bridge arrangement: two sensors facing opposite poles can be summed instead of subtracted, which simplifies the analogue front end.
When a substitute has to be found for an obsolete analog sensor, the how to verify a drop in replacement page sets out the sensitivity and slope checks, and the pin to pin cross reference page covers what has to match when the body changes from SOT-23 to TO-92.
Questions we get on this code
Why is the quiescent output 1 V rather than half the supply? Because the part is not ratiometric: it runs from 2.5 V to 38 V and the output range stays at 0.2 V to 1.8 V whatever the rail. That makes the reading independent of supply, which is convenient for a 24 V system, but it means the output cannot be read against the supply as a reference.
How much field can this part take before it clips? The output saturates near 1.8 V, which at 45 mV per mT is about 18 mT above the quiescent point. Beyond that the reading stops changing, and the data sheet is explicit that the linear behaviour ends at saturation rather than degrading gently.
A third point is temperature drift of the magnet rather than of the sensor. The sensitivity of the part is trimmed and held within 10 percent, but a ferrite magnet loses field as it warms, and that loss appears in the reading as a position error. On a mechanism that runs hot, the magnet grade matters as much as the sensor grade.