DRV5013BCELPGQ1
Product Specifications
DRV5013BCELPGQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV5013BCELPGQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV5013BCELPGQ1: a 38 V latch with a 12 mT operate point
The DRV5013BCELPGQ1 is the least sensitive member of the DRV5013 latch family, with an operate point of plus or minus 12 mT, and it is the member that survives the widest supply range. The part runs from 2.5 V to 38 V with no external regulator, which means the same sensor can sit on a 5 V logic rail or directly on a 24 V industrial rail with nothing in between. The output is open drain and sinks 30 mA, enough to drive an optocoupler or a relay driver without a buffer.
The 12 mT operate point is chosen for two situations. One is a magnet that has to sit far from the sensor, behind a wall of plastic or a metal shield. The other is a stray field environment where a sensitive part would trip on the motor current rather than on the magnet. In both cases the lower sensitivity is the feature, not a compromise.
Protection is built in. Reverse supply protection holds to minus 22 V, load dump is supported to 40 V, and the output has short circuit and current limit protection. Power on time is 35 microseconds, which is fast enough that a controller polling the sensor after a wake event does not have to wait for a settling delay. The die is chopper stabilized, so the operate point stays within 10 per cent over the whole temperature range.
Key data for the DRV5013BCELPGQ1
| Type | Digital bipolar latch, toggles on alternating north and south poles |
| Sensitivity | Operate point plus or minus 12 mT for the BC band, stable within 10 per cent over temperature |
| Supply | 2.5 V to 38 V, no external regulator required |
| Output | Open drain, 30 mA sink capability, short circuit and current limit protection |
| Timing | 35 microsecond power on time |
| Protection | Reverse supply to minus 22 V, load dump to 40 V |
| Temperature | Q grade minus 40 C to plus 125 C, E grade minus 40 C to plus 150 C |
Body, packing and marking data
| Body | TO-92 LPG, 3 leads, 4 mm by 3.15 mm |
| Packing | Bulk bag on the published BCE rows, ammo pack on the Q rows of the same family |
| Finish | Tin plated leads, moisture level not applicable for a leaded body |
| Temperature | Minus 40 C to plus 125 C on the BCE rows as printed, marking +NLAG or 1UVJ |
Order code note before you place the string on a purchase order
The string on this page does not appear verbatim in the addendum. The published BCE rows print the LPE lead frame, not the LPG, and none of them carries a Q1 suffix. The Q1 letter in this catalogue entry has to be confirmed with the vendor rather than read off the table, and the lead frame question matters because LPE and LPG are both three lead TO-92 parts with different bend geometry.
There is a second inconsistency worth knowing. The nomenclature describes E as the minus 40 C to plus 150 C grade and Q as minus 40 C to plus 125 C, while the BCE rows in the addendum print minus 40 C to plus 125 C and the 150 C rows belong to the QLPGM string. A purchase order that needs 150 C should name the Q grade string and not rely on the E letter alone.
Where a 38 V latch earns its place
Industrial valves, solenoid status sensing, flow meters, power tools and brushless motors on a 24 V rail all use this part, because the supply range removes the regulator that a 5 V only sensor would need. The 30 mA open drain output also lets the sensor drive an indicator or a small relay driver directly.
The 12 mT band is what makes the part usable next to a contactor coil, where a more sensitive latch would trip on the field the coil produces. Our obsolete part cross reference hub covers the older leaded sensors this part often replaces, and the how to verify a drop in replacement page is where the magnetic comparison belongs before a substitution is signed off.
Questions we get on this code
The first question is whether the part can run directly from a 24 V rail with a transient. It can run from 24 V continuously and survives a 40 V load dump, but a rail with repeated inductive spikes above 40 V needs a clamp, and the reverse protection only covers a supply that is connected the wrong way round.
The second question is about the output pull up. The output is open drain, so a resistor to the logic rail is required, and the resistor value sets both the rise time and the current the output sinks when it is low. A 10 k resistor into a 3.3 V rail is fine at low frequency, and a 1 k resistor is the choice when the cable to the controller is long.