DRV2605YZFR
Product Specifications
DRV2605YZFR
Texas Instruments — Power Management & Signal Chain
Product Overview
The DRV2605YZFR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV2605YZFR: An I2C Haptic Driver That Plays Stored Effects Instead of Streaming Waveforms
DRV2605YZFR is a haptic driver for eccentric rotating mass motors and linear resonant actuators with a licensed effect library in a DSBGA (YFF) body of 9 pins. It runs from 2.5 V to 5.5 V, sits on a shared I2C bus, and holds a licensed library of more than a hundred effects from Immersion, so the host writes a register instead of generating a waveform. The output stage is trinary modulated, which is more efficient than a linear driver, and a back EMF sensing loop tracks the resonance of a linear actuator and applies overdrive and braking automatically. The 9 ball package is 1.50 mm by 1.50 mm, which is the reason it appears in phones and watches.
Order code and package
| Ordering string | DRV2605YZFR, DSBGA, large reel |
| Family document | DRV2605, SLOS825E, December 2012, revised April 2018 |
| Package | DSBGA (YFF), 9 balls, 1.50 mm by 1.50 mm |
| Supply range | 2.5 to 5.5 V |
| Bus | I2C, address 0x5A, 1.8 V compatible pins |
| Effect library | licensed Immersion TouchSense 2200, over 100 effects |
| Actuator support | ERM and LRA, with auto resonance for the LRA |
| Regulator pin | REG at 1.84 V, needs a bypass capacitor |
| Inputs | PWM or analogue on the IN/TRIG pin, plus a hardware trigger |
| Sibling | DRV2605L, same function with a lower supply floor for small cells |
Electrical parameters that decide the application
| Supply voltage | 2.5 to 5.5 V, absolute maximum 6 V class |
| Quiescent current | about 1 mA in operation with the output idle |
| Shutdown current | 1.75 uA typical, 4 uA maximum |
| Standby current | 1.9 uA typical, 5 uA maximum |
| REG pin voltage | 1.84 V typical, bypassed to ground |
| Logic high threshold | 1.3 V, so a 1.8 V bus drives it directly |
| Logic low threshold | 0.5 V |
| Minimum load impedance | 8 Ohm |
| LRA frequency range | the driver tracks the actuator resonance within its window |
| PWM input frequency | 10 to 250 kHz |
| Output stage | trinary modulated, no output filter inductor |
| Auto calibration | offset and back EMF calibrated per actuator at start up |
| Shutdown output impedance | 15 kOhm to ground on each output |
| Thermal and overcurrent | internal shutdown with a fault register |
Family variants and how they differ
| DRV2605 | I2C, licensed library, auto resonance, the part on this page |
| DRV2605L | lower supply floor and a reduced library for small cells |
| DRV2604 | I2C with a RAM waveform store, no licensed library |
| DRV2604L | the low voltage member of the RAM store version |
| DRV2603 | PWM and enable only, auto resonance, no bus |
| DRV8601 | PWM input, no library and no tracking, the simplest member |
| What the library changes | the host no longer stores or streams waveforms |
| What the closed loop changes | the actuator is calibrated per unit and the resonance tracked |
Points to check before this part goes on a BOM
The licensed library is the reason to pay for this part rather than a plain driver. Each effect is a stored waveform with a defined attack, sustain and brake, tuned for the actuator class, and the host selects one by index over I2C. That removes the audio or haptic waveform from the firmware image, removes the timing jitter of a software PWM, and makes the feel consistent across products. The library is licensed, so the terms travel with the part rather than with a separate agreement, which is why an engineering team can use it without a legal negotiation and why the same effect sounds the same on two different phone models if the actuator is comparable.
The smart loop closes the control around the actuator instead of around the drive voltage. At start up the device measures the back EMF of the actuator and calibrates the resistance and the inductance, then during playback it uses that model to apply overdrive at the leading edge and active braking at the trailing edge. On an eccentric rotating mass motor this shortens the spin up and stops the tail, which is what makes a 20 ms click feel crisp. On a linear actuator it tracks the resonance, which drifts with temperature and with mechanical loading, and keeps the amplitude constant as the battery voltage falls.
Auto resonance is the feature that decides between this part and a fixed frequency driver. A linear resonant actuator has a resonance that moves by a few hertz between units and by more than that over temperature, and driving it off resonance produces a weak and slightly delayed response. The tracking loop sweeps the drive frequency, watches the back EMF phase, and locks to the peak, which is done continuously rather than at calibration. The price is that the actuator has to be characterised once on the bench with the intended mounting, because the loop needs a sane starting point and a mount that damps the resonance heavily will defeat it.
The 1.5 mm package and the 1.8 V compatible bus are what make the part fit a phone, and they also set the constraints. The 9 ball array needs a via in pad or a very short trace to the bypass capacitor on REG, which is 1.84 V and not a supply, so it must not be loaded. The shutdown current of 1.75 uA is low enough to leave the part powered between events, and the standby state keeps the calibration, so the first effect after wake is as strong as the tenth. A product that cuts the supply to save current loses the calibration and pays a fresh start up every time, which is visible as a weaker first click.
What has to be measured on the bench before release
Three measurements decide whether the haptic output will feel right in the product. The first is the actuator resistance and inductance, read by the calibration step and reported in registers, because a unit that reads far outside the batch average points at a wrong actuator or a bad solder joint. The second is the resonance frequency of a linear actuator in its final mount, which has to fall inside the tracking window of the driver, and which shifts when the mount is tightened. The third is the amplitude at the lowest battery voltage the product will see, because the trinary output stage loses strength as the supply falls and an effect tuned at 4.2 V can be noticeably weak at 3.4 V. All three are read over I2C and can be logged in the factory test step without extra fixtures.
Where this order code fits
Touch feedback in phones, tablets, watches, remote controls and automotive panels, where the effect has to feel the same on every unit. A team that wants a defined click without storing waveforms starts from the library; a team with its own waveforms uses the RAM store version. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can it drive two actuators? No, there is one differential output pair. Two actuators need two devices on the same bus, which is possible because the address is fixed per part and would then need a bus switch.
Does the host have to generate any waveform? No, it writes an effect index and a duration. The real time playback mode is available when the host wants to stream its own samples.
What happens if the actuator is not connected? The diagnostic and calibration step reports a fault in the status register, and playback produces no output rather than an overcurrent event.
Is the library usable in a medical product? The licence terms come with the part, but the actuator and the effect have to be validated in the end product regardless of the driver, so the answer depends on the product file.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.