- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
DRV110APWR: PWM current controller for solenoids, relays and valves in a fourteen pin TSSOP
DRV110APWR is a current controller that drives an external MOSFET to pull a solenoid in at a peak current and then hold it at a lower level in a TSSOP body of 14 pins. The device sets the pull in current, the time spent at that current and the hold current with three resistors, and the switching frequency with a fourth, so the coil current follows a shaped profile instead of a fixed voltage. The A suffix is the fourteen pin body, and the eight pin DRV110PWR is the smaller member of the same family.
Order code and package
| DRV110APWR | TSSOP PW, 14 pins, 2000 pieces on a large reel, marking 110A |
| DRV110APWRG4 | same body, same reel, G4 material code on the label |
| DRV110PWR | TSSOP PW, 8 pins, 2000 pieces on a large reel, marking 110 |
| Moisture level | Level 2, 260 C, one year floor life on every published row |
| Temperature | minus 40 to plus 125 C ambient, with the junction allowed to reach 150 C |
| Supply | 6 V to 48 V DC at the VIN pin, or 120 V and 230 V AC through a rectifier and a series resistor |
| Protection | internal zener on the supply pin, so a high voltage rail is dropped at the pin rather than on the board |
Electrical parameters that decide the application
| Peak current, internal setting | 270 mA minimum, 300 mA typical and 330 mA maximum with RSENSE at 1 ohm and PEAK tied to ground |
| Hold current, internal setting | 40 mA minimum, 50 mA typical and 65 mA maximum with RSENSE at 1 ohm and HOLD tied to ground |
| PWM frequency | 20 kHz nominal with OSC tied to ground, set lower or higher by a resistor |
| Maximum duty cycle | 100 per cent, so the MOSFET can be held on during the pull in ramp |
| Minimum duty cycle | 7.5 per cent, which is the floor the controller will not go below while regulating |
| Start up delay | 50 us typical from the enable pin going high to the first switching cycle |
| Keep time | 40 ms to 50 ms with a 1 uF capacitor on CKEEP, scaled by the capacitor value |
| Quiescent current | 570 uA typical with the enable pin high at 14 V and the bypass path inactive |
Family variants and how they differ
| DRV110APWR | 14 pin body with the full pin set, including the external peak and hold setting resistors |
| DRV110PWR | 8 pin body, the same core with fewer pins, used where the defaults are close enough |
| Internal settings | PEAK and HOLD tied to ground give 300 mA and 50 mA, which removes two resistors and two tolerances |
| External settings | RPEAK and RHOLD set the two levels against a 900 mV reference at 50 kohm |
| Bypass path | the internal regulator can be bypassed when the rail is already inside the gate drive window |
| G4 rows | the same silicon and reel as the plain row, with the material declaration recorded on the label |
Points to check before this part goes on a BOM
The peak level and the hold level are two separate resistor values, and the ratio between them sets the heat in the coil. A solenoid that holds at the same current it pulled in with will run at several times the dissipation it needs, which is the reason the hold level exists at all. The published internal setting is 300 mA peak against 50 mA hold, a ratio of six to one.
The sense resistor carries the full coil current, so its tolerance appears directly in both levels. A 1 per cent part is the practical choice, and the resistor has to be rated for the continuous hold current rather than the short pull in pulse.
The keep time is set by a capacitor, and the tolerance of that capacitor is larger than the timing window most valve makers quote. A ceramic capacitor with a stable dielectric is the safe choice. An electrolytic will drift with temperature and the peak window will move with it.
At 120 V and 230 V AC the supply pin sees a rectified rail, and the series resistor has to be sized for the worst case current. The internal zener clamps the pin, so the resistor dissipates the difference between the rail and the clamp voltage for as long as the coil is energised. That dissipation is the part of the circuit that fails first in a hot enclosure.
The junction may reach 150 C while the ambient rating stops at 125 C. A 14 pin TSSOP with a 24 V rail and a 20 kHz gate drive will run warm, so the copper under the body has to be sized for the dissipation rather than for the current alone.
A solenoid that is not mechanically free at the end of its stroke draws more current at the hold level. The controller will keep the current at the set point by reducing the duty cycle, so the fault appears as a hot coil and a low duty cycle rather than as an over current trip.
Choosing the MOSFET and the sense resistor together
The sense resistor sets the current and the MOSFET sets the voltage drop. At 300 mA a 1 ohm resistor drops 300 mV and dissipates 90 mW, which any 0805 part will take. The MOSFET on resistance adds to that drop and eats into the headroom between the rail and the coil, so a 100 milliohm part at 300 mA costs another 30 mV and 9 mW.
The gate charge matters more than the on resistance at 20 kHz. A part with 20 nC of gate charge at 15 V draws about 0.6 mA of average gate current, which the internal supply can deliver. A much larger FET will load that supply and pull the gate drive voltage down, and the coil current will fall short of the set point.
What the coil datasheet does not tell you
Pull in current is usually quoted at 20 C with the coil cold. Copper resistance rises with temperature, so at 85 C the same coil needs more voltage for the same current, and a supply sized at the cold figure will fail to pull in on a hot day. The hold level is where the margin has to be checked.
Release time is set by the decay path, not by the controller. A solenoid that is slow to drop out needs a higher clamp voltage, which raises the drain stress, so the two requirements are traded against each other on the same few components.
Where this order code fits
The part is used wherever a coil has to be pulled in hard and then held cheaply: gas and water valves in medical and industrial equipment, latching relays in telecom line cards, door locks and shutters in building control, and solenoid valves in test benches. In every case the load is inductive, the supply is fixed and the heat budget is the constraint. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.
Questions buyers ask
Can the device drive the coil directly? No. It drives the gate of an external MOSFET and senses the coil current through a resistor in the source or the return path. The MOSFET has to be chosen for the coil voltage and the peak current, with a gate charge the driver can move at 20 kHz.
What happens if the coil opens? The sense voltage falls to zero, the controller raises the duty cycle to the maximum and the coil sees the full rail until the controller reaches its limit. There is no open load detection in the device, so the fault is found by the host reading the status pin or by a current monitor on the rail.
Is a freewheel diode enough across the coil? A diode is the minimum. A diode plus a zener, or a diode plus a resistor, gives a faster decay and a shorter release time. The choice changes the voltage the MOSFET drain sees at turn off, so the drain rating has to cover the rail plus the clamp.
Why use the internal peak and hold setting instead of two resistors? It removes two resistors and their tolerances from the bill of materials, at the cost of fixing the current at 300 mA peak and 50 mA hold. That suits a coil whose datasheet current is close to those values and does not suit one that needs 450 mA.
Does the part need a heat sink in a sealed box? It needs copper. The dissipation is the gate drive loss plus the quiescent current times the supply, and both are small. The heat in a sealed enclosure comes from the series resistor and the coil, not from this device, so the copper pour is there to keep the junction below 150 C when the ambient is already at 85 C.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.