Product Overview

The BQ7790509PWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

BQ7790509PWR: factory programmed pack protector for three to twenty series cells in a twenty pin TSSOP

BQ7790509PWR is a stand-alone protector that cuts charge and discharge with two low side FET drivers on voltage, current and temperature faults, without any microcontroller in a TSSOP body of 20 pins. The protection thresholds and delays are programmed at the factory and the order code selects the set, so the part carries a specification rather than a register map. The 09 suffix sets a 3900 mV overvoltage trip, a 160 mV second level overcurrent trip and a 320 mV short circuit trip. Current draw in NORMAL mode is 6 uA, which is what makes a protector of this class usable on a pack that sits in a warehouse.

Order code and package

BQ7790509PWRTSSOP PW, 20 pins, 6.50 mm by 4.40 mm, 2000 pieces on a large reel, Level-2-260C-1 YEAR
BQ7790509PWsame body, 70 pieces in a tube, for prototypes and repair
MarkingB7790509 on the 09 rows, which is how a reel is identified when the label is gone
Temperatureminus 40 to plus 85 C operating free air temperature on the published rows
Stack range3 series to 20 series, extended further by cascading the CHG and DSG control pins
Cell pin rating36 V absolute maximum on each cell input, so the stack can be attached in any order
Supplypacks from 10.8 V to 72 V, with the device powered from the stack through VDD

Electrical parameters that decide the application

NORMAL mode current6 uA for both the BQ77904 and the BQ77905, which is the figure that sets shelf life
SHUTDOWN current0.5 uA maximum, entered when the pack is put away by the host or by the pack switch
Overvoltage trip3900 mV on the 09 order code, against 4250 mV on most other suffixes of the family
Overvoltage accuracyplus or minus 10 mV across the full temperature range
Undervoltage window1.2 V to 3 V programmable at the factory, with 200 mV or 400 mV of hysteresis
Second overcurrent trip160 mV with a 350 ms delay on this suffix, read across the sense resistor in the pack negative
Short circuit trip320 mV with no delay, which is the hardware path that survives a tool dropping across the terminals
Current accuracyplus or minus 20 per cent at or below 20 mV and plus or minus 30 per cent above 20 mV
Temperature tripsdischarge over temperature 70 C, charge over temperature 50 C, discharge under temperature minus 20 C, charge under temperature minus 5 C

Family variants and how they differ

BQ7790500 and BQ7790502lower overcurrent points, for packs whose load is a fixed motor rather than a variable tool
BQ77905084250 mV overvoltage with 2600 mV undervoltage and 400 mV of hysteresis, the wider window for a 4.2 V cell
BQ77905114250 mV overvoltage with a one second delay, 2700 mV undervoltage and an 85 mV first overcurrent point
BQ77905184175 mV overvoltage with a two second undervoltage delay, for packs that see long motor stalls
BQ7790521100 mV first overcurrent with a 90 ms delay and a 200 mV short circuit with a one second recovery timer
BQ77905223700 mV overvoltage and recovery by delay only, not by load removal, for a pack that is never disconnected

Points to check before this part goes on a BOM

The suffix is the specification. There is no trim register and no configuration pin, so a substitute with a different suffix is a different protector. Put the full order code on the BOM and on the incoming inspection record, because a reel of BQ7790508 will fit the footprint and protect at the wrong voltage.

Open wire detection is a separate function. The device checks that each cell connection is actually conducting, so a broken nickel strip raises an open wire fault instead of a false undervoltage on one cell. That matters on a pack that is welded rather than plugged, because a weld can look good and carry nothing.

The FET drivers are low side and they are not current limited. The CHG and DSG pins drive the gates of NMOS devices in the pack negative, and the device relies on the gate resistor and the FET to limit the switching edge. A very large FET bank needs a gate resistor chosen for the total gate charge, not copied from the previous pack.

Above six series the drivers have to be cascaded. The upper device drives the control pins of the device below it, which is how the family reaches twenty series and beyond. A cascade that is wired in the wrong order leaves the lower FETs permanently on, and the pack then has no discharge protection at all.

The second overcurrent point is the one that saves the FET. A 320 mV short circuit threshold with no delay is a comparator path, and the 160 mV point with 350 ms is what catches a stalled motor. Both are needed: one protects the FET, the other protects the cells from a slow overload that would otherwise run the pack hot.

Recovery by load removal is a product choice, not a fault. On this suffix the pack stays latched until the load is removed, so a product that keeps a small standby current will look dead after an overcurrent event. That is deliberate, and the product has to be able to release the load to recover.

Cascading past six series

The CHG and DSG control pins exist so that one device can be told to hold off by the device above it. In a sixteen series pack there are three or four of these devices, and the chain has to be built from the top of the stack down, with the top device the one that sees the whole stack.

The usual assembly mistake is to reverse the chain. The pack then powers up and works, which is the dangerous part, because the lower FETs are held on and only the top device can disconnect the pack.

What the 09 row is good for

A 3900 mV trip suits a pack whose cells are charged to a lower voltage than the 4.2 V default, and it also suits a pack that must be kept away from the top of the charge curve for life reasons. The cell and the protector have to be chosen together.

The second overcurrent point at 160 mV with 350 ms and the 320 mV short circuit point suit a tool with a high stall current. Both are read across the same sense resistor, so the resistor tolerance moves both thresholds together.

Where this order code fits

Power tools, garden tools, light electric vehicles, start-stop battery packs and lead-acid replacement packs use this protector class, because the pack must fail safe even if the tool controller has crashed. Energy storage and uninterruptible supplies use it where a microcontroller would add current draw and a firmware failure mode. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Drone UAV Components page.

Questions buyers ask

Why is the overvoltage point 3900 mV on this suffix? Because the pack it was programmed for must not be taken above that level. A standard 4.2 V cell would trip before it reached full charge with this part, so the suffix has to match the cell, and the cell datasheet has to be checked before the order code is chosen.

Can the thresholds be changed on the board? No. The reference and the comparators are trimmed and programmed at the factory, and the order code is the only way to select a set. That is the trade for having no register map, no bus and no firmware to corrupt.

What does the protector do with a cell that is missing? Open wire detection raises a fault on the channel that is not conducting, and the pack goes to a protected state. A pack assembled with one cell link left open therefore fails at the first power up rather than after a few cycles.

Is the current trip accurate enough to use as a measurement? No. The window is plus or minus 20 per cent below 20 mV and plus or minus 30 per cent above it, so the trip is a protection threshold and not a current reading. Anything that needs a number has to come from a gauge.

How does the pack recover after a short circuit? On this row the recovery is by load removal, so the short has to be cleared and the load released before the FETs turn back on. A pack that is welded into a product needs a service switch that can be opened, or the recovery has to be done by the charger removing the load.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Obsolescence Management page sets out the checks that keep a substitute from failing on the bench.