BQ76PL455ATPFCRQ1
Product Specifications
BQ76PL455ATPFCRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The BQ76PL455ATPFCRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ76PL455ATPFCRQ1: sixteen cell automotive battery monitor with an isolated daisy chain in an eighty pin TQFP
BQ76PL455ATPFCRQ1 is a battery monitor, protector and cell balancer for six to sixteen series cells, built for automotive packs and stacked up to sixteen devices deep in a TQFP body of 80 pins. The device converts every cell in 2.4 ms nominal through a 14 bit converter, compares each cell against programmable overvoltage and undervoltage thresholds with a second reference, and talks to the host over a capacitor isolated differential UART at up to 1 Mb/s. The Q1 suffix is the automotive grade row.
Order code and package
| BQ76PL455ATPFCRQ1 | TQFP PFC, 80 pins, 12 mm by 12 mm, 1000 pieces on a large reel, marking 76PL455ATQ1 |
| BQ76PL455ATPFCTQ1 | same body, 250 pieces on a small reel, same marking |
| Moisture level | Level 3, 260 C, 168 hour floor life, so the reel has to be baked after that window |
| Temperature | minus 40 to plus 105 C ambient, AEC-Q100 grade 2 |
| ESD | HBM level 2 and CDM level C3 |
| Cell count | 6 to 16 cells per device, with eight auxiliary inputs for temperature sensors |
| Isolation | capacitor isolated differential UART, evaluated against bulk current injection |
Electrical parameters that decide the application
| Cell input range | plus or minus 0.75 V around the previous cell tap, measured as the difference between two adjacent sense pins |
| Conversion time | all cells converted in 2.4 ms nominal |
| Accuracy at 25 C | 1 mV to 4.95 mV total channel error, quoted at a 3.6 V cell |
| Accuracy, 0 to 65 C | plus or minus 2.00 mV at a 1.5 V cell rising to plus or minus 4.25 mV at 3.6 V |
| Accuracy, minus 40 to 105 C | plus or minus 3.50 mV at a 1.5 V cell rising to plus or minus 6.25 mV at 3.6 V |
| Input current | 2 uA typical and 7.6 uA maximum on a selected channel, which sets the bleed on the cell tap |
| Auxiliary inputs | eight channels, 0 V to 5 V, for thermistors and other sensors |
| Digital I/O | six general purpose ports, configurable to raise a fault on the fault output |
Family variants and how they differ
| Overvoltage and undervoltage | two programmable comparators per cell input, against a second band gap reference |
| Balancing | passive balancing through external N channel FETs and power resistors, timed or commanded |
| Active balancing | supported with the EMB1428Q and EMB1499Q transformer drivers |
| Stack depth | up to sixteen devices in a daisy chain on one twisted pair host link |
| Self test | built in checks on the analogue and digital blocks, with a separate safety manual available |
| Open wire detection | a current source on each cell tap so a broken harness reads as a fault rather than a low cell |
Points to check before this part goes on a BOM
The accuracy table is written against the cell voltage, not against the full stack. A 3.6 V cell at 25 C carries 4.95 mV of total error, and the same part at 1.5 V carries 1 mV. A pack with a wide state of charge window therefore has a better error figure at the bottom of the window than a summary of the headline number suggests.
The input current on a selected channel is what limits the harness filter resistor. A 7.6 uA maximum bleed through a 1 kohm filter resistor drops 7.6 mV, which is larger than the converter error. The filter resistor and the input current have to be chosen together, and a tap that is left unselected draws nanoamps.
The second reference is the reason the protection path survives a main reference failure. Overvoltage and undervoltage comparison run on a separate band gap, so a fault in the measurement reference does not take the protection comparison with it. That separation is what makes the part usable in a pack that has to fail safe.
Open wire detection is a current source, not a voltage test. Each tap is pulled by a small current, so a broken wire shows as a tap that reads either rail rather than a cell that is low. A production test that only reads cell voltages will pass a harness with a marginal crimp.
The isolation is capacitive and it is part of the signal path. The differential pair carries the daisy chain data across the isolation barrier, so the routing of that pair and the quality of the coupling capacitors set the link margin. A stack that works on the bench and fails in a vehicle is usually a coupling capacitor tolerance problem.
Level 3 moisture with a 168 hour floor life is the handling note that gets missed. The reel has a working window after it is opened, and a body that has absorbed moisture will crack at reflow. The parts are baked or stored dry, and the label records the level.
What the harness costs and how to keep it cheap
Every cell tap needs a filter resistor and a capacitor, and every one of them is a place where a bad solder joint becomes a measurement error. Sixteen taps per device across six devices is ninety six chances, which is why open wire detection earns its place in a production test.
The filter resistor is also the part that decides the input current error. Keeping it at a few hundred ohms rather than a few kiloohms keeps the bleed below the converter error, at the cost of less filtering for the switching noise on the stack.
Reading the accuracy table without fooling yourself
The headline plus or minus 4.95 mV applies at 25 C with a 3.6 V cell. A pack that spends its life between 3.0 V and 4.1 V and runs from minus 40 to plus 105 C is in the minus 40 to 105 C rows, where 3.6 V reads plus or minus 6.25 mV.
The second trap is the cell window. The table is written for a cell between 2 V and 3.7 V for the fixed offset rows, so a LiFePO4 pack sitting near 3.3 V is inside the row and a pack with a 4.2 V top end is outside it, where the wider window figures apply.
Where this order code fits
Electric and hybrid vehicle packs, 48 V mild hybrid systems, energy storage racks and uninterruptible supplies, e-bikes and e-scooters. The automotive grade row is what a vehicle pack needs, and the same silicon serves a stationary rack where the cell count per device is the same but the environmental class is easier. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Obsolescence Management page.
Questions buyers ask
How many devices does a 96 cell pack need? Six, at sixteen cells each, chained on one host link. The chain is limited to sixteen devices, so a pack up to 256 cells is reachable on one link, and the practical limit is set by the link timing and the fault containment strategy.
Is the daisy chain a real isolation barrier? It is capacitor isolated, so it passes signal and blocks DC. It is not a safety isolation barrier in the sense of a reinforced insulation rating, and a pack that needs one adds a dedicated isolator at the host interface.
What does the part do if a cell tap opens? The open wire detection current pulls the tap to a rail, the adjacent cells read wrong, and the fault is reported as a measurement anomaly. The host has to interpret it, because the device cannot tell an open tap from a genuinely flat cell without the current source.
Can it balance while the pack is at rest? Yes, passive balancing can run whenever the host commands it or on a timer. The power resistors are external, so the balancing current is a board decision rather than a device limit.
Why is a 14 bit converter enough for a 1 mV target? Because the cell window is plus or minus 0.75 V, not the full stack. Fourteen bits across a 1.5 V window gives about 90 uV of resolution, and the error budget is then set by the reference and the input path rather than by the converter.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.