BQ76952PFBR
Product Specifications
BQ76952PFBR
Texas Instruments — Power Management & Signal Chain
Product Overview
The BQ76952PFBR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ76952PFBR: sixteen series battery monitor and protector with high side FET drive in a 7 mm TQFP
BQ76952PFBR is a pack monitor that measures every cell, counts charge through a sense resistor and drives high side protection FETs, for three to sixteen series packs in a TQFP body of 48 pins. The device runs two ADCs so that current and voltage are sampled at the same instant, and it holds a protection state machine that can act without a host. The charge pump drives high side N-channel FETs, which keeps the pack negative continuous, and the two LDOs supply the host and the isolation side from the pack.
Order code and package
| BQ76952PFBR | TQFP PFB, 48 pins, 7.0 mm by 7.0 mm, 1000 pieces on a large reel, Level-2-260C-1 YEAR, marking BQ76952 |
| BQ7695201PFBR to BQ7695205PFBR | same body and reel, different factory protection images, 1000 pieces each |
| Temperature | minus 40 to plus 85 C operating free air temperature |
| Packing | large reel only at 1000 pieces, with no tube row published for this body |
| Stack range | 3 series to 16 series Li-ion, Li-polymer and LiFePO4 |
| Cell pins | 85 V tolerant at cell connect and at the BAT pin, so the stack can be attached in random order on the line |
Electrical parameters that decide the application
| NORMAL mode current | 286 uA with the monitor awake, which is the figure a always-on pack has to budget for |
| SLEEP mode | 24 uA to 41 uA depending on which measurements stay enabled |
| DEEPSLEEP mode | 9 uA to 10 uA, for a pack that is stored and still needs to wake on an event |
| SHUTDOWN current | 1 uA, entered by command or by an undervoltage event |
| Current measurement | plus or minus 200 mV across the sense resistor, which covers a wide range of shunt values |
| Coulomb counter offset | below 1 uV typical, which is the figure that decides drift over a long rest |
| Cell voltage accuracy | better than 10 mV typical across the cell range |
| Communication | 400 kHz I2C, SPI and a one wire HDQ port, all on the same die |
| Temperature inputs | one internal sensor and up to nine external thermistors |
| LDOs | two programmable regulators for the host and for an isolated side, both fed from the pack |
Family variants and how they differ
| BQ76952 against BQ7695201 to 5205 | the same silicon with different protection settings and FET defaults burned at the factory |
| Protection drive | high side N-channel charge and discharge FETs through a charge pump, plus a separate precharge and predischarge path |
| Fuse drive | a dedicated pin for a secondary chemical fuse, which is the last resort protection in a pack that must not fail closed |
| Balancing | autonomous balancing on a timer or host controlled balancing through the register map |
| Thermistors | nine external channels, each with its own coefficient set, so cells and FETs can share one part |
| Reset and shutdown | the RST_SHUT pin distinguishes a reset from a shutdown by how long it is held |
Points to check before this part goes on a BOM
Random cell attach order is a production convenience, not a fault tolerance. The cell inputs survive 85 V, so a pack can be assembled with the connectors mated in any sequence and the device will not be damaged. The protection state machine still has to be configured to ignore the intermediate readings during assembly.
The one microvolt offset is what makes a long rest readable. Across a one milliohm shunt, one microvolt is one milliamp, so the drift over a month of rest is small enough that the reported state of charge does not walk away. With a five milliohm shunt the same offset is a fifth of a milliamp, which is why the shunt value and the offset have to be chosen together.
The OTP image is burned once. Protection thresholds, FET defaults and the balancing configuration can be locked in one time programmable memory at the pack line, which removes a configuration step from every pack. It also means a wrong image cannot be corrected, so the burn belongs after the first article is verified and not before.
Nine thermistors is a pack architecture decision. A cell that is hot in the middle of a stack will not show on a board sensor, so the thermistors belong on the cells, and the board sensor is for the electronics. A pack that only monitors the board will pass a thermal test and fail in the field.
The fuse drive is there for the case the FETs cannot handle. A pack that has welded its discharge FET or that sees a current beyond the FET rating needs a chemical fuse to open, and the device provides the drive for it. That output is a one shot, so the circuit around it has to be checked before it is ever triggered.
Two ADCs are what make a short circuit visible. Sampling current and voltage at the same instant means a load step shows as a current change without a voltage artefact, which is how a fast overcurrent decision is made without waiting for a second conversion.
Where the pack line goes wrong
The first loss is the cell tap harness. A sixteen series pack has seventeen sense wires, and one that is a few milliohms different from its neighbours shifts the balance current and makes one cell read low at high current.
The second is the sense resistor connection. The current path and the sense path have to meet at the resistor pads and nowhere else, or the copper between them adds a resistance that changes with temperature and the coulomb count drifts.
What the host has to configure
Protection thresholds, FET defaults, balancing mode and the thermistor coefficients are all register settings before they are ever burned to OTP. A pack that comes off the line with defaults is protected for a different chemistry and a different cell count.
The communication path is also a choice: I2C, SPI and HDQ are all available, and a product that switches interfaces has to be reconfigured rather than merely rewired, because the pin functions are shared.
Where this order code fits
Battery backup units, e-bikes and scooters, cordless power tools, garden tools and industrial packs above ten series use this monitor class, because the pack needs cell level protection and a communication path to a charger or a vehicle controller. The high side drive keeps the pack negative intact, which matters where the chassis is the return. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Drone UAV Components page.
Questions buyers ask
Does the pack need a microcontroller with this part? No for protection. The state machine trips the FETs on its own thresholds, and a host is only needed for reporting, balancing control and configuration. A pack that must report state of charge over a bus needs the host or a gauge.
Why high side FETs instead of low side? Because the pack negative stays continuous, so a charger, a load and a current sense path can all share one ground. Low side protection breaks that ground, which is a problem for a pack that also carries a communication interface.
How many cells can one part watch? Sixteen in series directly. A pack with more cells uses one device per sixteen with a communication bridge between them, and the bridge is a separate part rather than a mode of this one.
Is the 286 uA normal mode current a problem for a stored pack? It is for a pack that sits for months, which is what deep sleep at 9 uA and shutdown at 1 uA are for. The choice of mode is a product decision and it has to be made before the pack current budget is signed off.
What does the device do if a thermistor opens? The channel reads outside the expected range and the host sees a temperature fault rather than a temperature. That is why the thermistor network is usually a divider with a known open circuit voltage, so an open channel is distinguishable from a cold pack.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the One Stop BOM Sourcing page sets out the checks that keep a substitute from failing on the bench.