BQ24725ARGRR
Product Specifications
BQ24725ARGRR
Texas Instruments — Power Management & Signal Chain
Product Overview
The BQ24725ARGRR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ24725ARGRR: SMBus buck charge controller for one to four cells with an n-channel power path
BQ24725ARGRR is a host controlled synchronous buck charger that sets voltage, charge current and input current over SMBus and drives three external n-channel FETs for adapter selection in a VQFN body of 20 pins. The part regulates the pack from a 4.5 V to 24 V adapter and hands every limit to the host over SMBus, with a 0.5 per cent window on the pack voltage and 3 per cent on both current limits. Two charge pumps drive the ACFET, RBFET and BATFET separately, so the system can switch between adapter and pack without a second controller. The RGR body is 3.50 mm by 3.50 mm.
Order code and package
| BQ24725ARGRR | VQFN RGR, 20 pins, 3000 pieces on a large reel, NIPDAU, Level-2-260C-1 YEAR, marking BQ25A |
| BQ24725ARGRT | same body, 250 pieces on a small reel, listed as a separate row |
| BQ24725ARGRRG4 | the green row, same body and same 3000 piece reel |
| Cells | one to four series Li-ion cells, from 1.024 V to 19.2 V of regulation range |
| Switching frequency | 615 kHz, 750 kHz and 885 kHz, selected by SMBus |
| Temperature | minus 40 to plus 85 C on every published row of this body |
Electrical parameters that decide the application
| Adapter range | 4.5 V to 24 V operating, with the sense and VCC pins rated to 30 V absolute |
| Charge voltage | 1.024 V to 19.2 V in DAC steps, plus or minus 0.5 per cent, 4.192 V at the 0x1060H code and 12.592 V at 0x3130H |
| Charge current | plus or minus 3 per cent up to 8.128 A, read across a 10 milliohm sense resistor |
| Input current | plus or minus 3 per cent up to 8.064 A, set by the same resistor on the adapter side |
| Current amplifier | 20 times gain on the adapter or pack current, plus or minus 2 per cent above 40.96 mV of sense voltage |
| REGN | 5.5 to 6.5 V, 6.0 V typical, 75 mA current limit, used for the gate drives and the sense amplifier |
| BATFET drive | 6.1 V above the sense node, 60 uA of charge pump current, 4 kohm gate resistor limits the inrush |
| Adapter comparator | ACN to SRN trip at 120 to 280 mV, 200 mV typical, with 40 to 120 mV of hysteresis |
| Standby current | 0.65 mA typical and 0.8 mA maximum from the adapter, 5 uA of pack discharge with the part off |
| Protection | input overvoltage, cycle by cycle over current, inductor short, FET short and pack depletion |
Family variants and how they differ
| Pack current against adapter current | both are read from the same 20 times amplifier but on different sense resistors, and the host picks which one it converts |
| 615 kHz against 885 kHz | the lower frequency gives better efficiency at high current and the higher one gives a smaller inductor, and the choice is a register write rather than a part change |
| Internal limit against ILIM pin | the host can set the input current in a register or pull the ILIM pin down to reduce it in real time, and the lower of the two wins |
| Battery depletion against pack removal | the depletion threshold is programmable in four steps, and it turns the ACFET off rather than waiting for the pack to collapse |
| LEARN against normal charging | the LEARN function holds the pack at a reduced level so a host can calibrate its gauge, which is what a battery service routine needs |
| RGR against the larger bodies | the twenty pin 3.5 mm body carries the three gate drives and the sense amplifier, so the copper under the pad is the thermal solution |
Points to check before this part goes on a BOM
The host owns every limit, and that is the risk. Voltage, charge current and input current all come from registers, so a host that boots with its defaults before the charge profile is written will charge a three cell pack at the single cell default. The window is a fraction of a second on a healthy firmware, and it is the whole cycle on a firmware that hangs, which is why the part is usually enabled from a GPIO after the profile has been written.
Two sense resistors, one amplifier. The pack current is read across SRP and SRN and the adapter current across ACP and ACN, and both go through a 20 times amplifier with 2 per cent accuracy above 40.96 mV. Below that the accuracy falls to 4 per cent at half the voltage and 15 per cent at an eighth, so a 500 mA reading taken from this amplifier is a rough number and not a measurement.
The BATFET gate resistor sets the inrush. The document places a 4 kohm resistor from BATDRV to the gate, and its purpose is to slow the turn on so the system capacitor does not pull the pack down. A build that removes it to save a part gets a system rail that dips on every adapter removal, and the dip resets the very processor that is supposed to be managing the switch.
Adapter removal is a race the part wins only with help. When the adapter goes away the ACN to SRN comparator turns the BATFET on within a few microseconds, and the system capacitor has to hold the rail for that long. A 10 uF capacitor on a 3 A rail holds for about 20 us, which is enough, and a 1 uF capacitor on the same rail is not, so the bulk capacitance is part of the power path rather than a decoupling detail.
The 24 V adapter rating excludes transients. The pins survive 30 V and the converter regulates to 24 V, but an adapter that rings above 30 V on plug in will damage the sense pins before the overvoltage comparator acts. A TVS at the connector is the usual answer on a product that accepts a range of third party adapters.
Pack depletion is not pack protection. The programmable depletion threshold turns the ACFET off at a set fraction of the pack voltage, which protects the system from a collapsing pack. It does not protect the cells, because the protection circuit in the pack is a separate device, and a pack without one will be taken below its safe floor by the system load regardless of what this register says.
Where the board goes wrong
The three external FETs are the parts that decide whether the board survives. The ACFET and RBFET carry the adapter current continuously and the BATFET carries the system current with the adapter gone, so a FET picked for its on resistance at 10 V of gate drive and driven from a 6 V charge pump runs hotter than the datasheet table suggests.
The second fault is a sense resistor placed on the wrong side of the input capacitor. The adapter current is meant to be read with the capacitor ripple included, and moving the resistor changes both the limit and the loop, which shows up as a charger that limits early on a long cable.
What to ask a supplier for
Ask for the marking and the reel size with the code. The marking on this body is BQ25A, and a reel that carries a different marking is a different member of the family even when the order string looks close.
Ask also for the moisture level. This body is published at Level 2 with a one year floor life, so a reel that sat open needs a bake, and the label is the only record of the floor life that has already been used.
Where this order code fits
Notebooks, ultra portable terminals and medical carts that charge a two or three cell pack from an adapter and need the pack to take over without a glitch use this family. The SMBus control is what allows one board to serve several pack chemistries, because the profile lives in the host firmware rather than in a resistor. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Incoming Inspection Plan page.
Questions buyers ask
Does the part need a host to work? Yes. It powers up with the registers at their defaults and does not charge until the host writes the profile and enables the converter. A board that is expected to charge from a dead pack with no firmware running needs a different part or a bootstrap routine in the charger path.
How accurate is the pack voltage? Plus or minus 0.5 per cent over the full range, which at 12.6 V is about 63 mV. The regulation is trimmed in the factory and the DAC code is exact, so the error is in the reference and not in a divider, which is why this part is used where a gauge has to agree with the charger.
What happens when the adapter is removed? The ACN to SRN comparator turns on the BATFET and the pack feeds the system through its own FET. The part also enters a low quiescent state with about 5 uA of pack discharge, so a product left without an adapter does not drain through the charger.
Can the switching frequency be changed at runtime? The register allows 615 kHz, 750 kHz and 885 kHz, and the part blanks the output while it changes. That makes it usable as a thermal lever, but the inductor has to be chosen for the lowest frequency the product will ever select, because the ripple is highest there.
Is the 20 times amplifier a current monitor? It is, with 2 per cent accuracy above 40.96 mV of sense voltage and progressively worse below it. A host that uses it for a fuel gauge has to accept a 15 per cent error at an eighth of full scale, which is why the pack usually carries its own gauge.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.