Contact Us

BQ24125RHLR

Brand: Texas Instruments
Texas Instruments BQ24125RHLR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

BQ24125RHLR — Power Management & Signal Chain | Superb Automation

BQ24125RHLR

Texas Instruments — Power Management & Signal Chain

Product Overview

The BQ24125RHLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

BQ24125RHLR: switched mode charger with an external feedback divider in a twenty pin VQFN

BQ24125RHLR is a synchronous buck charger with integrated FETs that regulates the battery voltage through an external divider and charges at up to 2 A in a VQFN body of 20 pins. The 25 suffix in this family is the member that sets the charge voltage from a feedback pin, so any voltage between 2.1 V and 15.5 V can be set with two resistors. The 20 and 23 suffixes in the same body are fixed at 4.2 V and at 4.2 V or 8.4 V. Switching is fixed at 1.1 MHz, the FETs are inside, and the body is 3.5 mm by 4.5 mm with a thermal pad.

Order code and package

BQ24125RHLRVQFN RHL, 20 pins, 3.5 mm by 4.5 mm, 3000 pieces on a large reel, Level-2-260C-1 YEAR, marking CDZ
BQ24125RHLTsame body, 250 pieces on a small reel, marking CDZ
BQ24125RHLRG4same body and reel, G4 material code printed on the label
BQ24120RHLRfixed 4.2 V member of the family, 3000 pieces on a large reel, marking BQU
BQ24123RHLR4.2 V or 8.4 V selected by the CELLS pin, 3000 pieces on a large reel, marking BQV
Temperatureminus 40 to plus 125 C operating free air temperature on the 25 rows
Supply20 V absolute maximum on IN and OUT, with the converter itself running from an adapter inside that window

Electrical parameters that decide the application

Charge voltage2.1 V to 15.5 V, set by the divider on the FB pin, and fixed at 4.2 V on the 20 and at 4.2 V or 8.4 V on the 23
Voltage accuracy0.5 per cent at 25 C and 1 per cent over the full temperature range
Switching frequency1.1 MHz fixed, with a duty cycle range of 0 to 100 per cent
Charge currentup to 2 A with the integrated FETs, set by ISET1 and sensed across the battery sense resistor
Current regulationplus or minus 10 per cent on a 100 mV to 200 mV sense voltage across RSNS
Precharge and terminationa second current level set by ISET2, used below the low voltage threshold and as the termination point
Sleep current5.5 uA drawn from the battery when the adapter is removed
Thermal resistance39.2 C per watt junction to ambient in the RHL body, which is the figure that limits a continuous 2 A
Safety functionsbattery detection, thermal shutdown, reverse leakage protection and a programmable charge timer

Family variants and how they differ

BQ24120fixed 4.2 V, one cell only, the simplest member with no divider and no CELLS pin
BQ24123the CELLS pin selects 4.2 V or 8.4 V, which covers one and two cells without a divider
BQ24125the FB pin takes a divider, which is what makes three cell packs and any non standard voltage possible
Timer and terminationthe TTC pin sets both from one capacitor, and pulling it low disables both
Status outputscharge in progress, charge complete, fault and adapter present, each on its own pin for a host or an LED
G4 rowsthe same silicon and the same reel with a different material declaration on the label

Points to check before this part goes on a BOM

The divider sets the charge voltage, so the divider tolerance is the charge error. A one per cent pair gives a regulation point that sits inside the published window, and a five per cent pair does not, however good the part is. Compute the divider from the feedback reference in the electrical table and not from the nominal battery voltage.

The 20 V rating covers the adapter, not the transients on it. A 19 V notebook adapter with a long cable produces a ring on plug in that can pass 20 V at the pin. That is why the family is described for adapters up to 16 V in practice, and why a product that runs at the top of the window needs a clamp.

Termination is a current threshold, not a voltage one. The charger stops when the current falls below the ISET2 level, and a pack with high self discharge will fall below it later or restart the cycle after it stops. A charge that restarts after termination is normal behaviour and not a fault condition.

The enable pin must not be pulled above the system rail. The vendor note on this family is explicit: the input is referenced to the internal supply and pulling it to the battery rail biases a junction that is not rated for it. A level shifter from a higher logic rail is the safe path.

Battery detection is what keeps a pack with an open protector from being charged. The charger checks for a battery before it starts, so a pack whose protection FET is open looks like no battery and the charger reports a fault rather than pushing current into the pack terminals.

The thermal pad is the only heat path. At 39.2 C per watt in a 3.5 mm by 4.5 mm body, a continuous 2 A charge from a 12 V adapter into a depleted pack dissipates enough to reach the thermal limit without a via field under the pad. The thermal loop then reduces the current, which is visible as a charge that slows.

What the family has in common

All three members share the body, the pinout and the converter, so a board can be built for the 25 and populated with the 20 or the 23 without changing the copper. The difference is two pins: FB becomes a no connect on the 20 and CELLS on the 23.

That shared body is why the family is still sourced for repair. A product built ten years ago on the 20 can be repaired with a 25 set to 4.2 V by a divider, and the remaining pins do not need to change.

Where the charge curve surprises people

The precharge to fast charge transition happens at a fixed low voltage threshold, so a pack that arrives at 2.9 V sits in precharge at the ISET2 level and takes much longer to reach the fast charge region than the headline current suggests.

The second surprise is the timer. It is a safety backstop measured from the start of the cycle and not from the start of fast charge, so a long precharge eats into it, and a pack that is deeply discharged can hit the timer before it is full.

Where this order code fits

Handheld products, portable media players, portable DVD players and industrial or medical equipment use this family, because a fixed frequency converter with the FETs inside keeps the board area small and the emissions predictable. The feedback pin version is the one used where the pack is three cells in series or where the voltage is not a standard one. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Medical Device Components page.

Questions buyers ask

Why choose the 25 suffix over the 23? Because the voltage is set by a divider rather than by a pin. Where the pack is three cells, or where a pack has to be held below its nominal full charge for life reasons, the divider is the only way to get the number without a different part number for every voltage.

Can the two current levels be set to the same value? Yes, and some products do that to keep the precharge current equal to the fast charge current. It costs the ability to bring a deeply discharged pack up slowly, which is the reason the two levels exist in the first place.

What limits the charge current in practice? The thermal path and the inductor. The published 2 A is a converter rating into a pack that is not empty, and a sustained 2 A from a 12 V adapter into a 7.4 V pack will be limited by the 39.2 C per watt body before the current loop is.

Does the part need a host? No. The current levels come from two resistors, the timer from one capacitor and the voltage from a divider, so the charger runs stand alone. The status pins are there for a host or for two LEDs, and the product can ignore them.

How is a 2 A charge sensed? Across a resistor between the sense pins, with a published regulation window of 100 mV to 200 mV. A 50 milliohm resistor at 2 A develops 100 mV, which sits at the low end of that window.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.