Contact Us

AMC23C12DWVR

Brand: Texas Instruments
Texas Instruments AMC23C12DWVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AMC23C12DWVR — Power Management & Signal Chain | Superb Automation

AMC23C12DWVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The AMC23C12DWVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

AMC23C12DWVR fast reinforced isolated window comparator with adjustable threshold and latch

The AMC23C12DWVR is an isolated comparator rather than an isolated amplifier, and the distinction decides where it sits in a system. It does not measure a current or a voltage and hand a scaled copy to a converter. It compares the input against a threshold, and it asserts an open drain output when the input crosses that threshold, in 280 ns typical from the crossing to the output edge. On a drive that is the difference between a fault that is caught inside the short circuit withstand time of the power devices and one that is not.

The comparison window is centred on zero, so the part trips on the absolute value of the input. The threshold is set by a single external resistor, from 20 mV to 300 mV, which means the same body serves a shunt signal and a divided bus signal. Above 550 mV on the reference pin the negative comparator drops out and the part becomes a positive comparator with a threshold from 600 mV to 2.7 V, which is the mode used for supply monitoring.

Key parameters taken from the AMC23C12DWVR document

High side supply3 V to 27 V, which covers a 5 V, 12 V or 24 V control rail without a pre regulator
Low side supply2.7 V to 5.5 V, so the output can talk to a 3.3 V or 5 V controller
Window mode threshold20 mV to 300 mV adjustable through one external resistor, window centred on zero
Positive mode threshold600 mV to 2.7 V, active when the reference pin is above 550 mV
Reference current100 microamp plus or minus 1 percent, which is what makes a single resistor a usable threshold setting
Trip threshold errorPlus or minus 1 percent maximum at 250 mV
Response time280 ns typical propagation delay from input crossing to output edge
OutputOpen drain, with transparent mode when the latch pin is tied low and latch mode when it is driven
Common mode transient immunity55 V per nanosecond minimum
Isolation7000 V peak reinforced per VDE 0884-17, 5000 V RMS for one minute per UL1577, working voltage 1000 V RMS
TemperatureMinus 40 to plus 125 C, the full automotive range
BodySOIC DWV eight pins, wide body
Order code factsAMC23C12DWVR, 1000 pieces on a large reel, moisture level 3 with a 168 hour floor life, marking MC23C12, with a 64 piece tube row for prototypes
ApplicationsOvercurrent and overvoltage detection in motor drives, frequency inverters, solar inverters and DC to DC converters

The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.

Where the numbers matter in a real build

The threshold resistor is calculated from the 100 microamp reference, so the arithmetic is direct: resistance equals the threshold divided by 100 microamp, which gives 2.5 kilohm for 250 mV and 300 kilohm for the 30 mV end of the range. That simplicity is also the weakness, because a 1 percent resistor and a 1 percent reference give a threshold that is 2 percent off before any temperature drift is counted. For a protection threshold that is usually acceptable, and for a measurement it is not, which is why this part is a comparator and not a channel.

The 280 ns response time has to be compared with the short circuit withstand of the switch, not with the switching frequency. A silicon insulated gate bipolar transistor typically survives 6 to 10 microseconds in a short circuit, and a silicon carbide device rather less, sometimes under 3 microseconds. Removing the comparator delay, the gate driver delay and the current fall time from that budget leaves what is available for filtering, and that is where a filter built for noise rejection quietly eats the protection margin.

Latch mode is the feature that makes the output usable by a controller without a retry storm. In transparent mode the output follows the input, so a noisy threshold crossing produces a burst of edges. In latch mode the output holds until the latch pin sees a falling edge, which lets firmware decide whether the trip is real. On a drive the usual arrangement is latch mode with the latch released only after the controller has recorded the event and brought the bridge to a safe state.

The 27 V high side supply rating is what allows this part to sit directly on a 24 V control rail, which is common in industrial drives and in rail auxiliary supplies. A comparator that needs a 5 V rail forces a pre regulator on the isolated side, and the pre regulator is another part with its own failure mode. Running the high side from the rail that is already there removes a component and a failure path, and it also means the comparator's own supply is the voltage it often monitors.

  • Threshold resistor value against the 100 microamp reference, measured on the first article rather than assumed.
  • Total trip delay from a real overcurrent edge, including filter, comparator, gate driver and switch fall time.
  • Noise immunity at the switching edge, with the shunt and its filter as they will be built.
  • Latch release behaviour through the controller, including the state of the bridge while the latch is held.
  • High side supply at the bottom of the 3 V rating, with the comparator threshold checked again.
  • Creepage on the assembled board for the wide body, against the isolation file.

Which projects this part fits

This part fits overcurrent protection in motor drives, frequency inverters and solar inverters, overvoltage detection on a high side rail, DC to DC converter protection, and any isolated threshold that has to act faster than a controller can poll. It is also used as a secondary protection layer behind a current transducer, where the transducer feeds the control loop and this part feeds the trip. For customers building drives around wide bandgap devices, the response time and the 7000 V peak barrier are the two numbers that justify the part.

Questions that come up before a purchase order is released

Can the threshold be set for a 500 mV signal?

Not in window mode, which stops at 300 mV, and not in positive mode, which starts at 600 mV. A 500 mV threshold sits in the gap between the two modes, which is a real constraint and not an oversight: the mode is chosen by the reference voltage, and the two ranges were set for shunt signals and supply rails rather than for the space between them. A 500 mV signal needs a divider in front of the input.

How does the part behave with the input floating?

The output state depends on the input pins and the reference, so a floating input is not a defined condition and should not be relied on. In practice the input sits across a shunt or a divider, both of which give a low impedance path, and a broken sense connection is exactly the case where a supervisory circuit is needed. A series resistor and a pull down on the input are the usual guard.

Is the 1 percent threshold error at 250 mV the same at 20 mV?

The printed figure belongs to 250 mV, and the error at the bottom of the range is dominated by offset rather than by gain. A 20 mV threshold with a few hundred microvolts of offset is a several percent error, which is why the low end of the range is used for a coarse trip rather than for a precise one. Any channel that needs 20 mV of precision should use an amplifier and a converter.

What is the difference between the C12 and the C10 members?

The family separates the window comparator from the positive comparator variants and the latching from the non latching ones. This part carries the latch function and the window mode. A program that only needs a supply monitor takes the positive mode member, which is simpler to configure and does not need the window arithmetic.

How is the latch pin driven?

From the controller, on the low side, with a falling edge to release. The pin is referenced to the low side ground, so it is a normal logic signal. On a drive the controller should hold the latch until the bridge is disabled and the event is logged, because releasing it while the fault is still present simply re-asserts the output.

How SUPERB handles this line

We supply the AMC23C12DWVR from original reels with lot traceability and keep the tube row for prototype quantities, which is the practical difference between a two week and a two month start. The power management cross reference page lists the isolated protection and measurement families together, amplifier cross reference covers the amplifier that feeds the control loop next to this comparator, and component lead time solutions is where we record the alternatives when a body is on allocation.