AMC1303E2510DWVR
Product Specifications
AMC1303E2510DWVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The AMC1303E2510DWVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AMC1303E2510DWVR: 250 mV across a shunt, Manchester coded on the isolated side
AMC1303E2510DWVR is an isolated delta sigma modulator in the eight pin DWV body, the SOIC package that measures 5.85 mm by 11.5 mm, with a plus or minus 250 mV linear input range, an internal 10 MHz clock and a Manchester coded bitstream output. It converts the voltage across a shunt resistor on the high voltage side of a drive into a one bit stream on the low voltage side, across a capacitive barrier that is certified for reinforced isolation.
The code on the part number carries three decisions at once. The E means the output is Manchester coded, which lets the receiving device recover the clock from the data and removes one trace across the barrier. The 25 means the linear input range is 250 mV rather than 50 mV, which suits a shunt that drops more voltage and therefore needs less gain downstream. The 10 means the internal clock runs at 10 MHz rather than 20 MHz, which halves the output data rate and doubles the group delay relative to the fast version.
The figures below come from SBAS771D, revised October 2024, and from the orderable addendum printed in the same document. They are the ones we check against a customer current sense requirement before quoting, because the three numbers that decide whether a channel works are the input range against the shunt, the offset drift against the temperature the board actually reaches, and the data rate against the control loop bandwidth, and none of them can be read from the marketing page.
Reading the code: E, 25 and 10 are three separate decisions
The family has eight members and they differ in exactly three ways. The letter E or M selects a Manchester coded or an uncoded output. The digits 05 or 25 select a plus or minus 50 mV or plus or minus 250 mV input range, which also changes the differential input resistance from 4.9 k to 22 k. The digits 10 or 20 select a 10 MHz or a 20 MHz internal clock. Everything else, the isolation barrier, the offset and gain specifications, the temperature range and the package, is common to the family.
Those three choices interact more than the table suggests. A 250 mV range with a 22 k input resistance draws 11.4 microamps at full scale, while a 50 mV range with 4.9 k draws 10.2 microamps, so the two parts load a shunt almost identically and the choice of range is really a choice about the shunt value, not about the burden. The 250 mV range allows a 1 milliohm shunt at 250 A, or a 25 milliohm shunt at 10 A, and it allows the shunt to be a two terminal piece of copper alloy rather than a four terminal precision part at low currents.
The 10 MHz clock on this member gives a modulator data rate of 10 MHz and a usable output rate of 39 kSPS with a sinc3 filter at an oversampling ratio of 256. The 20 MHz member of the same family gives 78 kSPS. For a motor control loop running at 10 kHz to 20 kHz, 39 kSPS is enough samples and the extra rate is only worth paying for when the loop closes faster or when the filter order has to be raised for noise reasons.
The numbers that decide a current sense front end
| Function | Isolated delta sigma modulator for shunt based current measurement |
| Linear input range | plus or minus 250 mV for this order code |
| Differential input resistance | 22 k for the 250 mV members |
| Output format | Manchester coded CMOS bitstream, clock recovered by the receiver |
| Internal clock | 10 MHz nominal for this order code |
| Output data rate | 39 kSPS with a sinc3 filter at oversampling ratio 256 |
| Dynamic range | 85 dB at 78 kSPS in the 20 MHz members, the same modulator behind both rates |
| Offset error | plus or minus 100 microvolts maximum on the 250 mV members |
| Offset drift | plus or minus 1 microvolt per degree Celsius maximum |
| Gain error | plus or minus 0.2 percent maximum |
| Gain drift | plus or minus 40 parts per million per degree Celsius maximum |
| Common mode transient immunity | 100 kilovolts per microsecond typical |
| Reinforced isolation | 7000 V peak per DIN EN IEC 60747-17, VDE 0884-17 |
| Basic isolation | 5000 V RMS for one minute per UL1577 |
| Working voltage | 1500 V RMS |
| Analog supply | 3.0 V to 5.5 V on AVDD |
| Digital supply | 2.7 V to 5.5 V on DVDD |
| Ambient range | minus 40 to plus 125 degrees Celsius |
| Package | SOIC, DWV, 8 pins, 5.85 mm by 11.5 mm |
| Carrier | Large tape and reel, 1000 pieces, part marking 1303E251 |
| Moisture level | Level 3, 260 degrees, 168 hours floor life |
| Lead finish | Nickel palladium gold |
22 k of input resistance and why 250 mV is the right range here
A modulator with a 250 mV range and 22 k of differential input resistance draws 11.4 microamps at full scale. That current flows through the shunt and through the return path, and on a 1 milliohm shunt it develops 11.4 nanovolts, which is nothing. On a 100 milliohm shunt it develops 1.14 microvolts, which is also nothing against a 250 mV signal. The input resistance therefore does not distort the measurement, and the shunt can be chosen on thermal grounds rather than on burden voltage.
The offset specification is where the range pays. Offset error of 100 microvolts maximum on a 250 mV range is 0.04 percent of full scale, and offset drift of 1 microvolt per degree Celsius is 0.4 percent of full scale over a 100 degree swing. On the 50 mV member the same 50 microvolt offset is 0.1 percent of full scale, so the narrow range member is the more accurate part per volt and the 250 mV member is the more forgiving one. A drive that measures 200 A through a 1 milliohm shunt has 200 mV at full scale and no choice, and a drive that measures 10 A has a choice that should be made against the smallest current it has to resolve.
The gain drift figure of 40 parts per million per degree Celsius is the one that decides whether the measurement needs a temperature correction. Over 100 degrees that is 0.4 percent of reading, which on a 200 A channel is 0.8 A of apparent drift with no current flowing through any error mechanism other than the reference inside the modulator. If the drive uses the measurement for torque control, 0.4 percent is invisible. If it uses it for a protection threshold set at 105 percent of rated current, 0.4 percent is a quarter of the margin and has to be counted.
Manchester coding, the clock and the filter on the other side
The E members put a Manchester coded stream on DOUT, which means every bit carries its own clock transition and the receiver does not need a separate clock trace. That matters across an isolation barrier because every trace that crosses the barrier costs board space, a creepage allowance and a channel on the digital isolator that would otherwise not exist. The cost is that the receiver has to decode the Manchester stream, which is a small block in an FPGA or a dedicated input on a microcontroller, and the decoding has to tolerate the jitter of the recovered clock.
The M members put an uncoded stream on DOUT and a clock on CLKOUT, which is simpler for a receiver that already has a synchronous serial port and impossible for one that does not. The choice between E and M is therefore a choice about the receiving device, not about the accuracy, because the modulator behind both is the same silicon.
The filter that follows is a sinc filter, and the oversampling ratio sets both the data rate and the noise. At 10 MHz and an oversampling ratio of 256 the data rate is 39 kSPS and a sinc3 filter settles in three output periods, which is 77 microseconds. That is the number that belongs in a control loop budget: the measurement is 77 microseconds old when it is used, which at a 10 kHz loop rate is most of a period. A project that needs the measurement fresher moves to the 20 MHz member and the settle time halves.
7000 V peak, 5000 V RMS and the working voltage underneath
The barrier is certified to 7000 V peak of reinforced isolation under DIN EN IEC 60747-17, which is the standard that replaced VDE 0884-17, and to 5000 V RMS for one minute under UL1577. Those are the numbers that appear on a certificate and in a safety file, and they are not the number that decides whether the part survives a production line. The working voltage is 1500 V RMS, and that is the continuous voltage the barrier is rated to hold for the life of the product.
Between the working voltage and the transient rating sits the common mode transient immunity of 100 kilovolts per microsecond, which is what keeps the output clean when an inverter leg switches and the ground reference of the high side moves by hundreds of volts in tens of nanoseconds. A part with a lower figure produces bit errors at every switching edge, and those errors look like noise in the current measurement rather than like a broken isolator, which is why they are hard to diagnose in the field.
The clearance and creepage that the package offers is fixed by the DWV body, 5.85 mm of body width with the pin rows on the two long sides. A project that needs more creepage for a higher pollution degree moves to a wider body rather than adding a slot under the part, and the slot under a SOIC body is a common finding in a safety review that should have been a package change.
Where this part sits in a motor drive channel
A three phase drive has at least two shunt channels and often three, one per leg, and each channel is a shunt, a modulator and a filter. The modulator sits on the high voltage side with the shunt, the filter sits on the low voltage side with the controller, and the only thing between them is the barrier inside this package. That is the whole point of the part: it removes the amplifier, the level shift, the analog isolation amplifier and the separate supply that a discrete channel would need.
In a servo drive the same channel measures phase current for the field oriented loop, and the accuracy requirement is set by the torque ripple the application tolerates. In a photovoltaic inverter the channel measures string current for maximum power point tracking and for a protection threshold, and the accuracy requirement is set by the metering standard rather than by the control loop. Both use the same part with different shunts and different filters, and the selection question is the same in both cases: range first, then drift, then rate.
Ordering: DWV, 1000 piece reel, moisture level 3
This order code ships as 1000 pieces on a large tape and reel, with nickel palladium gold lead finish, part marking 1303E251, and a moisture sensitivity level of 3 with a 168 hour floor life at 260 degrees. Level 3 means the reel has to be kept dry and the parts have a 168 hour window out of the bag before a bake, which is a production planning item rather than a technical one, and it is the item most often missed when a line switches from one isolated part to another on a Friday afternoon.
The SOIC DWV body is 5.85 mm wide, which is wider than a standard narrow SOIC and is the reason the part does not drop into a footprint drawn for an ordinary eight pin package. Our ADC and DAC cross reference lists the isolated modulator alternatives with their body widths and pin arrangements, and our pin to pin cross reference covers the parts that are genuinely interchangeable rather than merely similar.
On the inspection side the barrier is inside the package and cannot be tested at incoming beyond the datasheet parameters, so the plan for this family is a first article with a known current source and a known shunt, a check of the bitstream at two temperatures, and a visual check of the lead finish and the date code. That procedure is in our incoming inspection plan under isolated converters, and it is the same procedure we use for the 50 mV member of the family.