Heat Sinks and Thermal Interface Pads for Power Boards
Product Specifications
Product Overview
A power stage fails on junction temperature, and the path out of the device is a chain: die to case, case to sink, sink to air. The sink and the interface are the two links a board team still chooses at layout time, so both belong on the same page. An extruded aluminium sink is picked for the resistance it shows at the air speed inside the enclosure. A still air figure of 13.4 C/W on a TO-220 sink and 20.3 C/W on a 27 mm BGA sink look weak until a fan is added, when the same parts reach 6.46 C/W at 200 LFM.
The interface material decides how much of that chain is wasted. Sil-Pad 900S is a glass reinforced silicone insulator at 0.229 mm: it isolates the tab electrically and still gives 3.96 C/W on a TO-220 at 10 psi, dropping to 2.32 C/W at 200 psi. Where the gap between a module and a wall is uneven, a soft gap pad is the better answer because it deflects instead of cracking. TG-A4500 is 4.5 W/mK at 50 Shore OO, and the softer grades in the same family are used where a thin ceramic or a large casting would otherwise be stressed.
Mounting pressure is the number most often left out of a thermal request. A 0.229 mm insulator needs the clip or screw torque to be stated, because the same pad reads 3.96 C/W or 2.32 C/W depending on how hard it is pressed. For gap pads the rule is the other way round: the pad must be compressed by ten to thirty percent of its free thickness and still fill the void. We ask for the device, the sink, the airflow and the fixing method before quoting, then return the resistance at the pressure the assembly can actually hold.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Sink material | Extruded aluminium, black anodised or bare | All sinks on this page |
| Sink footprint | 23 x 23 mm, 27 x 27 mm, 35 x 35 mm, TO-220 extruded | Per part number |
| Sink height | 18 mm fin height on the square channel parts | 374124, 374424, 374724 |
| Thermal resistance, still air | 13.4 to 23.4 C/W | Per part number |
| Thermal resistance, 200 LFM | 5.15 to 7.39 C/W | Square channel parts |
| Insulator thickness | 0.229 mm glass reinforced silicone | Sil-Pad 900S |
| Pad conductivity | 1.6, 3.5, 4.5 and 6.2 W/mK | Per part number |
| Pad thickness range | 0.5 to 8.0 mm on the gap pads | TG-A series |
| Pad hardness | 35 to 50 Shore OO | TG-A3500 and above |
| Dielectric strength | 10 to 13 kV/mm | TG-A3500, TG-A4500, TG-A6200 |
| Operating temperature | -60 to 180 C for the insulator, -50 to 180 C for the pads | Per part number |
| Fixing | Screw, clip, push pin or adhesive backed pad | Per assembly |
Included Models and Order Codes
The rows below are the sinks and pads we quote most often for power boards, radio modules and instrument castings. Resistance is given at the airflow stated, because a still air figure and a 200 LFM figure are not comparable. A dash means the maker does not publish that value for the part.
| Part Number | Type | Size or Thickness | Thermal Performance | Notes |
|---|---|---|---|---|
| 374124B00035G | Extruded channel sink, plastic clip | 23 x 23 x 18 mm | 23.4 C/W still air, 7.39 C/W at 200 LFM | 6 fins, 1.4 mm fin thickness |
| 374424B00035G | Extruded channel sink, plastic clip | 27 x 27 x 18 mm | 20.3 C/W still air, 6.46 C/W at 200 LFM | 8 fins, 4.0 W at 80 C rise |
| 374724B00032G | Extruded channel sink, metal clip | 35 x 35 x 18 mm | 15.3 C/W still air, 5.15 C/W at 200 LFM | 10 fins, 1.4 mm fin thickness |
| 531002B00000G | Extruded radial fin sink for TO-220 | TO-220 footprint, black | 13.4 C/W still air | Radial fins, equal channel spacing |
| SP900S-0.009-00-54 | Glass reinforced silicone insulator | 0.229 mm sheet | 3.96 C/W at 10 psi, 2.32 C/W at 200 psi on TO-220 | 1.6 W/mK, 92 Shore A, UL 94 V-0 |
| TG-A3500 | Soft silicone gap pad | 0.5 to 8.0 mm | 3.5 W/mK | 35 Shore OO, 13 kV/mm |
| TG-A4500 | Soft silicone gap pad | 0.5 to 8.0 mm | 4.5 W/mK | 50 Shore OO, 10 kV/mm minimum, 3.1 g/cm3 |
| TG-A6200 | Soft silicone gap pad | 0.5 to 8.0 mm | 6.2 W/mK | 50 Shore OO, 10 kV/mm |
Key Features
Resistance stated at airflow – Each sink carries the still air figure and the 200 LFM figure, so a part is not compared at the wrong air speed.
Clip style listed – Plastic clip and metal clip parts are separated, because the clip decides how much pressure reaches the insulator.
Insulator and gap pad on one page – A thin 0.229 mm insulator and a 4.5 W/mK gap filler are selected by gap and pressure, not by conductivity alone.
Pressure sensitivity spelled out – The Sil-Pad figure is given at five pressures from 10 to 200 psi, so the mounting torque has a number to aim at.
Thickness range on the pads – 0.5 to 8.0 mm covers a machined flat wall as well as a casting with a warp of a few tenths.
Electrical isolation included – The insulator is a dielectric as well as a conductor of heat, which matters where a tab sits at rail voltage.
Applications
These parts cover the thermal path on power supplies, radio power stages, motor drives and instrument enclosures.
DC-DC and motor drive stages – A 27 mm channel sink at 20.3 C/W in still air holds a pair of TO-220 devices in a sealed box, and the same part at 6.46 C/W with a small fan covers a higher dissipation without a larger footprint.
RF power modules – A soft 3.5 or 4.5 W/mK pad between a flange and a machined wall fills the gap left by flatness tolerance, which a thin insulator cannot do without excess pressure.
Instrument and enclosure builds – A TO-220 radial sink at 13.4 C/W plus a 0.229 mm insulator keeps a linear regulator off its limit inside a closed instrument case.
The sink is fixed to the same SUPERB PCB that carries the power stage, and the pad is cut to the footprint on the SUPERB PCBA drawing before assembly starts.
Sourcing and Cross-Reference
Thermal parts are ordered against four numbers: the device, the available footprint, the airflow and the fixing method. A request that gives only the device usually comes back with two or three options at different costs, because a 35 mm sink at 15.3 C/W can replace a 27 mm part at 20.3 C/W when there is room for it.
Pads are the harder half. The same conductivity can be sold at two thicknesses and two hardness values, and only the compressed thickness in the assembly decides the result. We confirm the gap, the pressure and whether the joint has to come apart for rework before quoting, and we keep the part number tied to the maker drawing so a second build gets the same sheet.
SUPERB Assembly applies the pad at the compression stated on the drawing and records the screw torque on the first article.
Q: Can you supply the same pad thickness and hardness as the part already qualified in our build?
A: SUPERB Tech keeps the sink, the insulator and the fixing as one line item, so a replacement sink cannot arrive without a pad that matches it.
Why Buy Heat Sinks and Pads Through SUPERB
- Resistance at your airflow: The still air and 200 LFM figures are both quoted, so the sink is judged at the air speed the enclosure provides.
- Pressure matched to the fixing: The insulator figure is given against mounting pressure, and the clip or screw that can reach it is quoted with the part.
- Gap measured, not assumed: Pad thickness and hardness are confirmed against the real gap before the order, which avoids a joint that is either loose or over stressed.
- Second build consistency: The maker drawing number is recorded with the order, so a repeat build receives the same sheet and the same hardness.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Common Mode Chokes and Power Inductors, Power Management ICs for Optical Modules, IGBTs and SiC Power Devices, Component Lead Time Solutions.