INA148UA/2K5
Product Specifications
INA148UA/2K5
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA148UA/2K5 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA148UA/2K5: Difference amplifier that measures across plus and minus 200 V of common mode
INA148UA/2K5 is a difference amplifier in the eight pin SO body with a fixed gain of one that accepts a common mode voltage of plus and minus 200 V on a plus and minus 15 V supply, draws 260 uA and holds 86 dB of rejection in a SOIC-8 body of 8 pins. The INA148 is a monolithic difference amplifier with a thin film resistor network that sets a gain of exactly one and allows the inputs to sit far outside the supply rails. On a plus and minus 15 V supply the common mode range is plus and minus 200 V, on a plus and minus 5 V supply it is plus and minus 100 V, and on a single 5 V supply with the reference at 0.25 V it reaches plus 75 V. Gain error is 0.075 percent maximum, non linearity is 0.002 percent, and the quiescent current is 260 uA.
Order code and package
| Order code | INA148UA/2K5 |
| Gain | 1 V per V, fixed by a thin film network |
| Common mode range at plus and minus 15 V | plus and minus 200 V |
| Common mode range at plus and minus 5 V | plus and minus 100 V |
| Common mode range at 5 V single supply | plus 75 V with the reference at 0.25 V |
| Supply, single | 2.7 V to 36 V |
| Supply, dual | plus and minus 1.35 V to plus and minus 18 V |
| Package | eight pin SOIC |
| Packing | 2500 pieces per reel |
Electrical parameters that decide the application
| Common mode rejection | 86 dB typical, 70 dB minimum |
| Gain error | 0.075 percent maximum |
| Non linearity | 0.002 percent maximum |
| Quiescent current | 260 uA |
| Input voltage, peak for 0.1 s | plus and minus 500 V |
| Input noise at 1 kHz | 880 nV per root hertz |
| Lead temperature for soldering | 300 C for 10 s |
| Reference input | sets the output level for zero differential input |
Points to check before this part goes on a BOM
Eighty six decibels of rejection on a 200 V common mode range means the common mode error is 200 V divided by 19953, which is 10 mV at the output. That is the number to compare against the signal, and it explains why this part is used for a bus voltage measurement and not for a shunt measurement: a 50 mV shunt signal under a 200 V common mode would be buried in the common mode error. The gain error of 0.075 percent on the same 200 V signal is 150 mV, which is larger still, so the part is at its best when the differential signal is a substantial fraction of a volt.
The resistor network is the part that makes the high common mode range possible, and it is also the part that sets the input impedance. A difference amplifier built from a matched divider presents a finite impedance to both inputs, and that impedance loads the source. On a high impedance source the loading produces a gain error that adds to the 0.075 percent, and the error differs between the two inputs unless the source impedances match. A 1 kohm imbalance with a 20 kohm input impedance is a 5 percent error, which is why the document asks for matched source impedances and why a series resistor on one leg only is a mistake.
The peak rating of 500 V for 0.1 s is a survival specification and it is much larger than the 200 V operating range. The gap covers the moment when a bus is switched or a contactor opens. A 400 V bus that rings to 500 V for a few milliseconds is inside the survival rating and outside the operating range, so the reading taken during that interval is not valid, which matters for a system that samples the bus continuously and treats each sample as a measurement.
The quiescent current of 260 uA is low for a part that has to stand off 200 V, and it is achieved by running the input stage at a low current rather than by a chopper. The consequence is a noise density of 880 nV per root hertz, which over a 1 kHz bandwidth is 28 uV, small against a signal of a volt and significant against a signal of 10 mV. The noise and the offset between them define the smallest differential signal this part can usefully resolve, and that floor is around a millivolt after a modest filter.
The common mode range depends on the supply in a way that is easy to misread. At plus and minus 15 V the range is plus and minus 200 V, which is more than ten times the supply; at plus and minus 5 V it is plus and minus 100 V, which is ten times the smaller supply. The ratio holds because the input divider is fixed and the amplifier behind it sees the divided voltage. A board that lowers the supply to save power also lowers the range, and a 200 V bus needs the plus and minus 15 V supply to stay inside it.
A single supply of 5 V with the reference at 0.25 V gives a common mode range of minus 4 V to plus 75 V, which is an asymmetric window that suits a high side measurement on a positive bus. The reference at 0.25 V sets the output at 0.25 V for zero differential input, so the output can swing down to the reference and up toward the positive rail. The choice of reference is therefore the choice of where the zero sits, and a rail to rail output amplifier downstream has to be able to accept the bottom of that swing.
The eight pin body with a fixed gain of one has no external components beyond the supply decoupling, which removes the resistor matching problem that a discrete difference stage has. The price is that the input impedance is fixed and finite, so the source has to be able to drive it. In a battery test system the cell is a low impedance source and the loading is irrelevant; in a sensor bridge it is not, and a buffer is needed in front of the part.
Where this order code fits
This order code belongs on battery cell formation and test equipment, high side current sensing in 48 V and 96 V systems, motor phase voltage measurement and any instrumentation that has to look at a signal sitting far above its own supply. It is also the part chosen where the measurement has to survive the full bus voltage on the input during a fault, because the input range of 200 V is a range the part operates in rather than a transient it survives. Teams comparing it with a neighbouring part start from our Amplifier Cross Reference page, and teams replacing a part that has gone end of life start from the Power Management Cross Reference page.
Questions buyers ask
Can it measure a shunt on a 200 V bus? It can measure the bus voltage, and it is a poor choice for the shunt. The common mode error at 200 V is 10 mV at the output and the gain error is 150 mV, both far larger than a typical shunt signal. A dedicated current sense amplifier with a high common mode range and a matched gain stage is the right part for the shunt.
What supply does a 200 V measurement need? Plus and minus 15 V, because the common mode range scales with the supply and reaches plus and minus 200 V only at that point. A plus and minus 5 V supply reaches plus and minus 100 V, which is not enough headroom for a 200 V bus with any transient.
Why does source impedance matter? Because the input is a resistor divider and the source drives it. An imbalance of 1 kohm against a 20 kohm input impedance is a 5 percent gain error, which dwarfs the 0.075 percent specification. Both legs need the same series resistance, and a filter on one leg only is a common mistake.
How much noise does it contribute? 880 nV per root hertz at 1 kHz, which is 28 uV over a 1 kHz bandwidth and 88 uV over 10 kHz. Against a signal of a volt that is negligible; against a signal of 10 mV it is the limiting term, so the bandwidth of the following stage is what sets the usable resolution.
SUPERB holds and sources this amplifier line against the exact order code, with the reel, date code and country of origin stated on the offer. When a measurement channel has to move to a second part, the BOM Shortage Recovery page sets out the checks that separate a working substitute from one that fails on the bench.