VBGP1201N
Product Specifications
VBGP1201N
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBGP1201N from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBGP1201N: 200 V and 120 A in a TO247 body
The VBGP1201N is a single N channel MOSFET in a TO247 body, rated at 200 V drain to source, plus or minus 20 V on the gate, a 4 V threshold, 120 A of drain current and 8.5 milliohm at a 10 V gate. It sits between the 150 V and 250 V members of the same family and in the same package, which makes it the middle option for a 110 V bus that needs margin.
200 V is the class for a 110 V DC bus with a real transient allowance, for the primary of a converter fed from a 150 V rail, and for a battery string at 110 V that can be charged to 130 V. It is also the class the circuit needs when the 150 V part works on paper but the drain node has a spike that the clamp cannot fully remove.
The 4 V threshold tells you this is not a logic level part. It is meant to be driven from a 10 to 12 V rail with a proper driver, and the 8.5 milliohm column is a 10 V column. Driving it from 5 V is possible only at low current, where the loss is small enough not to matter.
Key data for the VBGP1201N
| Configuration | Single N channel |
| Package | TO247, through hole |
| VDS | 200 V |
| VGS | Plus or minus 20 V |
| Vth | 4 V typical |
| ID | 120 A, a die figure at a 25 C case |
| RDS(on) at 10 V | 8.5 milliohm |
| Technology | Shielded gate trench |
| Body diode | Intrinsic, cathode at the drain |
| Loss at 40 A | 13.6 W through the channel |
| Derating at 80 per cent | 160 V continuous working voltage |
| Gate charge | Not printed, ask for the curve at 130 V drain |
Why the middle voltage wins on a 110 V bus
A 110 V bus with a 200 V part leaves 90 V, a 55 per cent derating. That is more margin than most circuits need, and it buys the ability to survive a spike without a clamp for the first few nanoseconds. Where the load is inductive and the switch opens fast, the peak on the drain is set by the leakage inductance and the capacitance at the node, and a part with 90 V of headroom turns a marginal spike into a non event.
The cost is resistance. An 8.5 milliohm die at 200 V is about twice the resistance of a 150 V die of the same area, so the conduction loss at 40 A is 13.6 W against about 7 W for the 150 V part. On a converter that runs at 40 A continuously, that difference is a bigger heatsink or a bigger fan, and the decision comes down to whether the transient is real or hypothetical.
For a battery string at 110 V that is charged to 130 V, the 200 V class is not optional. The top of charge plus the equalisation allowance can reach 140 V, and a 150 V part is outside its derated window before any transient is added.
Paralleling two of them, and what that costs
Two 8.5 milliohm dies in parallel give 4.25 milliohm, which is where a circuit ends up when a single 200 V part cannot take the current. The sharing depends on the source path: each part needs its own gate resistor, and the two source connections have to meet at a point where the copper resistance is small against 8.5 milliohm. A shared source pin with current from both dies through one length of copper is the usual reason a parallel pair fails.
The second issue is the threshold spread. Two dies with 4 V thresholds plus or minus half a volt turn on at different times, and the first one to turn on takes the whole current for the crossover window. At 100 kHz that window is a small fraction of the period but it is the window where the loss is concentrated.
Matching from one wafer lot helps and it is not something a catalogue part guarantees. Where the parallel bank matters, ask for the threshold spread of the lot and keep the pair from the same date code where possible.
Where the part fits and where it does not
It fits a 110 V bus switch, the low side of a motor drive on a 110 V pack, the primary switch of a converter fed from a 150 V rail, a battery disconnect on a 110 V string charged to 130 V, and a synchronous rectifier on a 110 V output. It does not fit a rectified 220 V main, a 200 V bus at full derating, or a converter where 8.5 milliohm at 60 A is too much loss for the heatsink available.
For a 200 V switch that is being matched against an original after a line change, the deciding parameters are the threshold, the resistance at the gate voltage in use and the body diode recovery. Our pin to pin cross reference page covers how a candidate is compared on the parameters that decide behaviour rather than on the headline current.
The sourcing side of this part is covered on the obsolete part cross reference hub. For a 200 V part whose original code has ended, that page covers the route from the old code to a part that can be bought.
Questions we get on this code
Can it be driven at 5 V? At low current, with a small loss, yes. At 40 A the die is not fully enhanced at 5 V and the 8.5 milliohm figure does not apply. Use a 10 V driver rail.
What is the working voltage with derating? At the common 80 per cent rule, 160 V. That covers a 110 V bus and a 130 V charged pack, and it does not cover a 150 V rail with a transient.
How much heatsink for 40 A? 13.6 W of conduction loss plus the switching loss. A TO247 on a 1 C per watt heatsink at 25 C ambient runs the case near 50 C, which is comfortable. Without a heatsink, 13.6 W will not stay inside the junction limit.
What should a purchase order carry? Part number, TO247, and the packing form. We confirm tube or taped quantity on the offer.