Contact Us

VBE1151M

Brand: VBsemi
VBsemi VBE1151M is a discrete semiconductors component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

VBE1151M — Discrete & Power Semiconductors | Superb Automation

VBE1151M

VBsemi — Discrete & Power Semiconductors

Product Overview

The VBE1151M from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

VBE1151M: 150 V at 15 A in TO252 with a 100 milliohm channel

The VBE1151M is a single N channel MOSFET in a TO252 body rated at 150 V, plus or minus 20 V on the gate, 15 A of drain current, with a threshold of 1.89 V and 100 milliohm on resistance at a 10 V gate, on trench silicon.

One hundred and fifty volts is the class that sits between the 100 V parts used on 48 V rails and the 200 V parts used on offline converters. It covers a 96 V battery, a 110 V DC bus, and the reflected voltage of a flyback running from a 90 to 265 V mains input with a low turn ratio.

The resistance is the honest part of the listing. One hundred milliohm at 15 A is 22.5 W of conduction loss, which no DPAK can pass, so the current rating and the resistance have to be read together before a thermal decision is made.

Key data for the VBE1151M

ConfigurationSingle N channel
PackageTO252, DPAK, exposed drain tab
VDS150 V
VGSPlus or minus 20 V
Vth1.89 V
ID15 A
RDS(on) at 10 V100 milliohm
TechnologyTrench
Body diodeIntrinsic, reverse recovery applies in bridge circuits
Thermal pathDrain tab to copper or heatsink
Gate chargeNot published on the catalogue page
Typical use96 V battery, 110 V DC bus, primary side switching
IsolationNone, the tab is the drain

Reading 100 milliohm against a 15 A rating

At 100 milliohm and 15 A the conduction loss is 22.5 W. A TO252 with a copper plane gives around 45 degrees per watt, so the rise would be over 1000 C, which is nonsense. The two numbers cannot both be true at once, and the data sheet resolves it by giving the current at a case temperature, usually 25 C, that only a heatsink can hold.

A practical figure: with 2 W of dissipation and 45 degrees per watt, the rise is 90 C, and at 100 milliohm that is 4.5 A. With a proper heatsink the rise can be halved and the current roughly doubled. The part is therefore a 4 to 9 A device in a real board, and the 15 A rating is a pulse or a case held cold.

This is the single most common misunderstanding in a BOM review. A buyer sees 15 A and 150 V and assumes the part can switch 15 A. The engineer sees 100 milliohm and plans for 5 A. Both are reading the same line, and the second reading is the one that ships.

150 V in a flyback primary

In a flyback running from a rectified mains, the drain sees the input voltage plus the reflected secondary voltage plus the leakage spike. With a 400 V bus, a 150 V part is usable only with a low reflected voltage and a well clamped leakage inductance, which usually means a snubber and a tight transformer.

In a 96 V battery system the same part has more room. The bus is 96 to 110 V under charge, and the switch sees the bus plus the leakage spike, so 150 V gives 40 V of margin at nominal and less at full charge. A 200 V part is the safer choice when the battery can be charged to 120 V or when the cable inductance is unknown.

The body diode matters in any bridge or synchronous rectifier. A 150 V body diode has a reverse recovery charge that turns into loss and ringing at every commutation, and the catalogue page does not publish it, so the data sheet has to be consulted before the part is used as a rectifier.

One number that decides whether the part survives a 96 V battery is the safe operating area during a short circuit. A battery pack can deliver hundreds of amps into a fault, and the switch has to turn off within a few microseconds while carrying that current at the full bus voltage. A 150 V die in a DPAK has a limited short circuit window, usually a few microseconds at the rated current and less at higher currents. The catalogue page does not print this curve, so a battery disconnect that relies on the switch to clear a fault has to be confirmed against the data sheet and, in most products, backed by a fuse that opens before the die fails.

Where the part fits and where it does not

It fits a 96 V battery disconnect, a 110 V DC bus load switch, a low power primary side switch in an offline converter with a clamped drain, and current source or linear regulator duty where dissipation is managed by a heatsink. It does not fit a hard switched 400 V flyback, and it does not fit a bridge without checking the body diode recovery.

Our how to verify a drop in replacement page sets out the checks made before a 150 V part is swapped for another, which is where the resistance, the gate charge and the diode recovery have to be compared rather than the headline ratings.

The sourcing side of this part is covered on the obsolete part cross reference hub. For a 150 V part whose original source has ended, that page covers the route from the old code to a part that can actually be bought.

Questions we get on this code

Is 150 V enough for a 110 V bus? At nominal, yes. At full charge with a cable spike, no. Measure the spike with the real load before deciding, and allow 20 per cent margin above it.

How much copper does the tab need? A square centimetre of two ounce copper under the tab is the usual starting point. More copper helps, and vias to an inner plane help more than a bigger surface area.

Is the threshold of 1.89 V enough for a 10 V driver? Yes. It gives more than 8 V of overdrive, which is why the part is specified at 10 V and not at 4.5 V.

What should a purchase order carry? Part number, TO252, reel size and date code. We quote from what is confirmed at the time of the request.