VBA4436
Product Specifications
VBA4436
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBA4436 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBA4436: a minus 40 V dual P channel at minus 6 A
The VBA4436 is a dual P channel MOSFET in an SOP8 body with minus 40 V per device, a plus or minus 20 V gate window, a minus 2 V threshold, a continuous drain current of minus 6 A, a pulse figure of minus 30 A and resistances of 51 milliohm at 4.5 V and 38 milliohm at 10 V.
A pulse rating of minus 30 A is unusual to see printed next to a 6 A continuous figure, and it is the most useful number on the page. It says the die can take five times its continuous current for a short interval, which is what a load switch does when it closes into a capacitive load or what a motor driver does at stall.
The rest of the page is the familiar P channel trade: 51 milliohm at a 4.5 V gate in a body with no exposed pad, which puts the working current at a few amps per channel whatever the headline says.
Key data for the VBA4436
| Configuration | Dual P channel |
| Package | SOP8, surface mount, 1.27 mm pitch |
| VDS | Minus 40 V per device |
| VGS | Plus or minus 20 V |
| Vth | Minus 2 V |
| ID continuous | Minus 6 A |
| ID pulse | Minus 30 A |
| RDS(on) at 4.5 V | 51 milliohm |
| RDS(on) at 10 V | 38 milliohm |
| Technology | Trench |
| Gate charge | Not published on the catalogue page |
| Body diode | One per channel |
| Thermal path | Eight leads, shared frame, no exposed pad |
What a 30 A pulse rating is good for
A load switch that closes into a 100 microfarad capacitor on a 24 V rail draws a current set by the capacitor, the switch resistance and the source impedance. With 60 milliohm of total loop resistance the peak is about 400 A in principle, and in practice the wiring limits it to a fraction of that. The die sees a current spike that lasts for the time constant of the loop, tens of microseconds, and the pulse rating is what says the die survives it.
The pulse rating also matters for a motor. A small brushed motor at stall draws several times its running current, and the driver sees that current until the controller reacts. A 6 A continuous part with a 30 A pulse rating can drive a motor that stalls at 15 A if the stall is brief, which no 6 A part without a pulse rating could be assumed to do.
What the page does not say is how long the pulse can last, which is the parameter that actually decides survival. That comes from the safe operating area chart in the data sheet, and it should be read before a pulse requirement is accepted.
Forty volts, two channels and the gate clamp
On a 24 V rail the gate source voltage reaches 24 V when the gate is pulled to ground, which exceeds the 20 V window. Two P channels in one body make the clamp slightly more complicated, because both gates need it, and a single zener across one gate does not protect the other.
The threshold of minus 2 V is high enough that a 5 V logic drive gives 3 V of overdrive, which reaches a usable resistance without a level shifter. That is the configuration where the 4.5 V column, 51 milliohm, is the operating point, and it is the reason a 40 V P channel is often preferred over a 20 V part on a 12 V rail: the margin is larger and the gate can be driven from the logic rail.
Two channels at 3 A each and 51 milliohm dissipate 918 mW total, which an SOP8 can pass on a board with a reasonable copper landing. At 6 A each the total is 3.7 W, which it cannot.
The pulse rating deserves a measurement rather than a calculation. A current probe on the source lead during a cold start shows the actual inrush shape, which is usually a spike followed by a decaying plateau rather than a clean pulse, and the die sees the integral of that shape. If the plateau is longer than a few hundred microseconds the loss is no longer a pulse problem and the steady thermal path takes over, which for an SOP8 means the inrush has to be limited by a series element or by a controlled gate ramp rather than left to the die.
Where it fits
It fits a 24 V load switch with a clamped gate, a motor driver for a small brushed motor, a battery path switch on a 24 V pack, and two high side switches on separate rails. It does not fit a 40 V rail, and it does not fit a continuous 6 A per channel in still air.
Our date code management page covers how age is tracked in stores, which matters for a dual P channel because the parts sit in stock longer than the fast moving logic on the same board.
The sourcing side of this part is covered on the purchase order follow up. For a part with a pulse rating that has to be confirmed against a fault current, that page covers what is settled on an order.
Questions we get on this code
How long can the 30 A pulse last? The catalogue does not say. The safe operating area chart in the data sheet gives the answer, and it depends on the gate voltage as well as the time.
Does the pair need one gate clamp or two? Two, one per gate. A single clamp on a shared gate node leaves the other device unprotected if the gates are separate.
Is minus 40 V enough for a 36 V pack? A charged 36 V pack is 42 V, so no. Use a 60 V class part for a 36 V pack.
Can both channels be used on the same rail? Yes, with their own gate resistors, and the thermal sum has to be added before the current is fixed.