VBA2412
Product Specifications
VBA2412
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBA2412 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBA2412: a minus 40 V P channel at minus 16.1 A
The VBA2412 is a single P channel MOSFET in an SOP8 body with a minus 40 V drain to source rating, a plus or minus 20 V gate window, a minus 2 V threshold, a drain current of minus 16.1 A and two resistance columns, 14 milliohm at 4.5 V and 10 milliohm at 10 V, on trench silicon.
Forty volts is the class that a 24 V system wants and a 36 V battery pack needs. It leaves room for a 24 V rail at plus 10 per cent, 26.4 V, and for a load dump that is clamped rather than absorbed, and it does not leave room for an unclamped inductive event.
The threshold of minus 2 V is the number to watch. It is three times higher than the minus 0.6 V of the 20 V part above, and the difference changes how the switch behaves at a 3.3 V gate drive: the overdrive is 1.3 V, which is enough for a load switch and not enough to promise the published resistance.
Key data for the VBA2412
| Configuration | Single P channel |
| Package | SOP8, surface mount, 1.27 mm pitch |
| VDS | Minus 40 V |
| VGS | Plus or minus 20 V |
| Vth | Minus 2 V |
| ID | Minus 16.1 A |
| RDS(on) at 4.5 V | 14 milliohm |
| RDS(on) at 10 V | 10 milliohm |
| Technology | Trench |
| Gate charge | Not published on the catalogue page |
| Body diode | Intrinsic, forward drop sets reverse polarity loss |
| Thermal path | Eight leads into the board copper |
| Published applications | Power tool motor drive, inverter stage, general power control |
Two columns, and the gate drive that goes with each
Fourteen milliohm at 4.5 V and 10 milliohm at 10 V is a 40 per cent spread, which is normal for a 40 V P channel. The 4.5 V column is the one a 5 V logic rail gives, since the gate is pulled to ground and the gate source voltage equals the rail. The 10 V column needs either a 10 V gate drive or a rail of at least 10 V, which most 24 V systems have.
On a 24 V rail the gate sees 24 V when it is pulled to ground, which is above the 20 V window. That is not a theoretical concern: the gate source voltage in a 24 V high side switch reaches the rail voltage on every on event, so the gate node has to be clamped or driven through a divider or a zener. A part rated at plus or minus 20 V in a 24 V circuit is being used outside its rating unless the gate clamp is there, and the clamp is not a detail of the board, it is part of the switch.
The alternative is a small N channel in the gate path with a resistor divider, which turns the single component switch into a three component one. That is still cheaper than a charge pump, and it is the arrangement most 24 V circuits use with a 40 V P channel.
Sixteen amps and a 40 V die
At 10 milliohm and 16.1 A the conduction loss is 2.6 W, which no SOP8 can pass continuously in still air. The working current is nearer 9 to 11 A on a board with good copper, where the loss is 0.9 to 1.2 W and the junction rise stays under 80 C. The published current is a die limit and should be read as such.
For a motor drive application the duty matters more than the average. A power tool motor pulls a stall current several times its running current for a fraction of a second, and the die survives that if the safe operating area allows it. The catalogue page does not publish an SOA chart, so a stall-current requirement has to be checked against the data sheet before the part is committed.
The inverter application named on the page is the other end of the scale: a low frequency bridge with a 40 V rail and a few amps per leg, where the switching loss is small, the conduction loss dominates and the thermal path through the leads is adequate because the current is modest.
Where it fits
It fits a 24 V high side switch with a clamped gate, a 36 V battery disconnect, a power tool motor drive, and a low frequency inverter leg. It does not fit a 40 V rail, and it does not fit any circuit where the gate is driven straight from the rail without a clamp.
Our obsolete part cross reference hub page is the route when the original P channel on a board goes end of life, which for this class of part usually means a change of threshold and gate charge rather than a change of resistance.
The sourcing side of this part is covered on the supplier corrective action. For a high side switch whose gate clamp is part of the circuit, that page covers how a field return is closed out.
Questions we get on this code
Can the gate be tied to ground on a 24 V rail? No. The gate source voltage would be 24 V against a 20 V window. Use a divider or a clamp so the gate sits no more than 15 V below the source.
Is 40 V enough for a 36 V pack? A fully charged 36 V pack is 42 V, so no. Use a 60 V part for a 36 V pack, and keep this one for 24 V systems.
How does it compare with an N channel plus a charge pump? The N channel will be cooler and smaller for the same current, and the charge pump is three extra parts. Below 8 A the P channel is usually the simpler answer.
What should be on the order? Part number, body, quantity and the rail voltage. The rail decides whether the gate clamping is adequate before anything else is discussed.