HXN50214
Product Specifications
HXN50214
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HXN50214 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HXN50214: fifty watts at 5 to 6 GHz on a 28 volt rail
The HXN50214 is a gallium nitride power transistor from Hisiwell filed on the 5 to 6 GHz window with 50 W of peak output on a 28 V rail in continuous wave. Fifty watts is 46.99 dBm. The index row carries no gain, no efficiency, no package and no thermal resistance, so this page is built from the one published power row plus the arithmetic that follows from it.
The part sits at the bottom of a three step ladder on the same band: 50 W here, 100 W at the HXN50217 and 140 W at the HXN50222. The same die family is usually behind such a ladder, which means the network topology carries from one rung to the next and only the impedance transformation and the sink change.
At 50 ohm the output is 50.0 V RMS and 70.7 V peak, which is the same set of numbers as the 50 W HX446050F2 on the wider 4.4 to 6 GHz band. That is not a coincidence, it is the same power into the same load. Under a two to one mismatch the peak reaches 100.0 V, which puts the match capacitors at 100 V minimum and 250 V for comfort.
The current is where the missing efficiency row hurts. At 100 per cent drain efficiency the drain would draw 1.79 A, at 50 per cent 3.57 A and at 40 per cent 4.46 A. A supply sized on the first number is a supply that browns out in the first minute of a key down test.
The band is 1 GHz wide, 18.2 per cent fractional at 5.5 GHz. For an unmatched part that is a moderate window, and a two section ladder on a low loss laminate holds it without a tuning stub per unit.
The parameter rows behind the HXN50214
| Part class | Gallium nitride HEMT power transistor, unmatched |
| Frequency range | 5 to 6 GHz |
| Band width, calculated | 1,000 MHz |
| Fractional bandwidth at 5.5 GHz centre, calculated | 18.2 per cent |
| Peak output, index row | 50 W |
| Peak in dBm, calculated | 46.99 dBm |
| Saturation output column | Not published |
| Average output column | Not published |
| Power gain | Not published |
| Drain efficiency | Not published |
| Drain current at 100 per cent efficiency, calculated | 1.79 A, a floor and not a real figure |
| Drain current at 60 per cent, calculated | 2.98 A, 33.3 W of heat |
| Drain current at 50 per cent, calculated | 3.57 A, 50.0 W of heat |
| Drain current at 40 per cent, calculated | 4.46 A, 75.0 W of heat |
| DC input at 50 per cent, calculated | 100 W |
| Drain rail | 28 V |
| Mode | Continuous wave |
| Load voltage at 50 ohm, calculated | 50.0 V RMS, 70.7 V peak |
| Load voltage under a two to one mismatch, calculated | 100.0 V peak |
| Load voltage at 12.5 ohm, calculated | 25.0 V RMS, 35.4 V peak |
| Output per gigahertz of band, calculated | 50 W per GHz |
| Matching | Unmatched, network on the customer board |
| Package and body | Not published on the index row |
| Thermal resistance, junction to case | Not published |
| Compression point | Not published |
| Gain flatness over the band | Not published |
Three point six amps and fifty watts of heat
At 50 per cent efficiency the part leaves 50 W of heat for 50 W of output, which makes a continuous wave 50 W stage a 100 W thermal problem in a small box. A flange on a forced air sink handles it, and the interface between flange and sink is the joint that decides whether the junction sits at 110 or at 140 degrees.
The current path at 3.57 A is a 200 mil trace at one ounce copper, a choke rated above 5 A and a bulk bank that holds the rail through the crest of a modulated signal. If the part is used with a modulated carrier the current crest is a multiple of 3.57 A and the choke is sized on that.
The output network is inexpensive at this power. Fifty volts peak and 100 V under mismatch means 100 V capacitors with margin, and a two section ladder with modest circulating current. That is the practical advantage of the bottom rung: the match costs less than on the 100 W and 140 W members.
The drive power is the unknown. With no gain row, the drive could be anywhere from 0.5 W for a 20 dB part to 5 W for a 10 dB part, and that range decides the driver line up. It is measured on a sample before the driver is bought, and it is the first question sent to the factory.
HXN50214 against the other parts on 5 to 6 GHz
| HXN50214 | 5 to 6 GHz | 50 W peak | Not published | Not published | Reference point |
| HXN50335 | 5 to 6 GHz | 70 W peak | Not published | Not published | 1.46 dB more peak |
| HXN50217 | 5 to 6 GHz | 100 W peak | Not published | Not published | 3.01 dB more peak |
| HXN50222 | 5 to 6 GHz | 140 W peak | Not published | Not published | 4.47 dB more peak, pulse mode |
| HX5060140P2 | 5 to 6 GHz | 140 W saturation | 11 dB | 50 per cent | 4.47 dB more output with gain and efficiency published |
| HX446050F2 | 4.4 to 6 GHz | 50 W saturation | 15 dB | 55 per cent | Same output, wider band, complete datasheet |
The last row is the comparison a buyer should run first. The same 47 dBm on a wider band, with 15 dB of gain and 55 per cent efficiency published, is a project that can be planned from a datasheet. This part is the same power with the rows missing, and the only reason to take it is availability or a price that reflects the difference.
Against the rungs above it the ladder is exactly 1.46 dB per step for the 70 W member and 3.01 dB to the 100 W. A system with 3 dB of margin on a 47 dBm requirement lands on the 100 W part, and this page exists so that the 50 W rung is not mistaken for a complete specification.
The 5 GHz parts are indexed on RF component sourcing, and the way an incomplete index row is qualified before a build is set out on RF power transistor cross reference.
Board notes for a fifty watt continuous stage at five and a half gigahertz
The first item is the drive. With no gain row, the sample measurement comes before the driver purchase, and it is taken at 5.0, 5.5 and 6.0 GHz so the flatness is known at the same time.
The second item is the sink. Fifty watts of heat in continuous wave needs a flange and a forced air sink, and the interface material is specified rather than chosen at the line.
The third item is the match. A two section ladder on a low loss laminate holds 18.2 per cent, and the network is tuned at the band edges as well as the centre.
The fourth item is the current path. At 3.57 A the trace, the choke and the ground return are all normal, and if the carrier is modulated the choke moves up a size for the crest.
Questions buyers ask about HXN50214
Is 50 W continuous? The row is a peak figure with a continuous wave mode. For a continuous part the two are close, and the sample settles it.
What is the gain? Not published. That is the first figure measured on a sample and the first question to the factory.
What is the efficiency? Not published, so the heat table on this page is a range at 40, 50 and 60 per cent.
Is it the same die as the 100 W part? Not stated. The ladder suggests a family, and a family is a hypothesis until the factory confirms it.
How do we start? Send the band, the output at the connector, the signal, the ambient and the rail. We will confirm the missing rows, quote from the schedule and ship a sample measured at 5.0, 5.5 and 6.0 GHz.