Contact Us

HXC50128

Brand: Hisiwell
Hisiwell HXC50128 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXC50128 — Discrete & Power Semiconductors | Superb Automation

HXC50128

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXC50128 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXC50128: a 750 W pair on HF to 200 MHz and what 1.5 kW changes for the network

The HXC50128 is an LDMOS RF power transistor from Hisiwell filed on the HF table with a 0.2 GHz top frequency and a 750 times two output row. It is the second rung of that table, one step below the 2 kW pair and one step above the 1 kW pair at 300 MHz. Read on its own, it is a 1.5 kW push pull stage for the band around 200 MHz.

The top frequency in the row is written as 0.2 GHz, which is 200 MHz, and the bottom is written as HF. That is a very wide window: at the low end the enclosure is the matching network, at the top end the network behaves like a lumped circuit with a real sensitivity to physical spacing. A buyer who quotes one gain figure across the whole span is quoting a class figure, and the vendor publishes no gain for this row at all, so nothing has to be reconciled yet. What has to be reconciled is the power.

1500 W is 61.76 dBm. Each half is 750 W at 58.75 dBm, and the sum of two equal halves is 3.01 dB above one, so the arithmetic of the pair is the same as on every other row of this table. Where this row differs from the 2 kW part is in what the rail and the cooling have to do to reach it.

The HXC50128 rows as the vendor publishes them

Part classLDMOS RF power transistor, push pull pair
Frequency range, index rowHF to 0.2 GHz
Top frequency in MHz, calculated200 MHz
Wavelength at the top of the window, calculated1.5 m in air
Saturated output, index row750 W times two
Pair total, calculated1500 W, 61.76 dBm
Per side, calculated750 W, 58.75 dBm
Step below the 2 kW pair, calculated1.25 dB
Drain rail, index row50 V
Load voltage at 1500 W into 50 ohm, calculated273.9 V rms, 387.3 V peak
Peak against the rail, calculated7.75 times
Load voltage per side at 750 W, calculated193.6 V rms, 273.9 V peak, 5.48 times the rail
Peak at a two to one mismatch, calculated774.6 V
DC input at 55 per cent, calculated2727 W, 54.5 A at 50 V, 1227 W of heat
DC input at 65 per cent, calculated2308 W, 46.2 A at 50 V, 808 W of heat
Output per megahertz of window, calculated7.5 W
GainNot published
Drain efficiencyNot published
Mode, index rowCW
Matching statedNothing on the row or the table header about internal matching
Package and flangeNot published
Thermal resistance, junction to caseNot published
Load impedanceNot published, no load pull table
Data sheetNone reachable for this row
Orderable addendumNone published

What 1500 W asks of the rail, the combiner and the heatsink

1500 W into 50 ohm is 273.9 V rms and 387.3 V peak, which is 7.75 times a 50 V rail. The transformer that steps the pair up to 50 ohm therefore sees a voltage swing that no single discrete capacitor rated at 100 V would survive, and the output network is normally built from series stacks or from a coaxial transformer rather than from a handful of surface mount parts. This is the practical reason HF and low VHF stages look like radio transmitters and not like microwave amplifiers.

The current side is the supply. At 55 per cent efficiency the pair pulls 54.5 A from a 50 V bus and produces 1227 W of heat; at 65 per cent it pulls 46.2 A and produces 808 W. Neither figure is published, so both are arithmetic on an assumed efficiency. The difference between the two, 419 W, is larger than most amplifiers dissipate in total, which is why an efficiency figure belongs in the purchase order and not in a footnote.

The combiner is the third element. A push pull pair delivering 1500 W has to combine two 750 W branches with better than 0.3 dB of loss, or 100 W of the total appears as heat inside the combining network instead of at the load. At 200 MHz that network is built from ferrites and capacitors, and its balance is what separates a clean 1500 W stage from a pair of devices fighting each other.

Why the 200 MHz band suits a pair this size

200 MHz sits in VHF band III, which is where digital audio broadcast and a number of land mobile and telemetry systems operate. Systems in that band usually want between 500 W and 2 kW from one transmitter, which is exactly the range this table covers in pairs. The pair format also suits the antenna side: a 200 MHz site is often a combining site with several transmitters on one mast, and a balanced pair drives a balanced combiner more cleanly than two independent single ended stages.

There is a second reason the band matters. At 200 MHz, a quarter wavelength is 375 mm in air, so a quarter wave stub is a real mechanical object that can be built to a millimetre tolerance and adjusted afterwards. That gives the builder a tuning element that does not exist at 2 GHz, and it is why HF and VHF stages are often aligned on the bench after assembly rather than by selecting components.

The cost of that is repeatability. A stage that is aligned by hand depends on the person who aligned it, and the record of the alignment is part of the product. A buyer who plans to build the same transmitter in volume should ask for the alignment procedure together with the devices, not only for the devices.

Reading the HF table as a ladder

From the top, the table offers 2 kW at 150 MHz, 1.5 kW at 200 MHz, 1 kW at 300 MHz and 1.4 kW at 500 MHz, then a step down to a 350 W pair and a set of single ended parts from 250 W to 80 W. The power does not fall smoothly with frequency, and that is the first thing a buyer should notice: the 500 MHz pair at 1.4 kW is larger than the 300 MHz pair at 1 kW, so frequency alone does not order this table.

The HXC50128 sits at the point where the pair power is still measured in kilowatts and the window is still wide in octaves. Above 300 MHz the windows narrow in ratio and the parts become easier to match but harder to cool, because the same power is concentrated in a smaller die. Below 200 MHz the windows stay wide and the network becomes the dominant cost. The family comparison across frequency, power and drive is on the RF power transistor cross reference page.

One more comparison matters to a buyer with an existing amplifier: 1.5 kW is 1.25 dB below 2 kW. If the existing stage is 2 kW and the requirement has not changed, this row is not a drop in replacement, it is a 15 per cent power reduction. If the requirement is 1.2 kW with margin, this row is the cheaper part and the smaller supply.

Buying the HXC50128: what the order has to state

The order should carry the frequency band inside the HF to 200 MHz window, the rail, the mode, the flange and body variant, the quantity, and the gain and efficiency figures the factory will guarantee. Because neither figure appears on the row, the acceptance test cannot be written without them, and a test written against an assumed number is a dispute waiting to happen.

The incoming test should measure each half and then the pair, and it should record the balance. On a 1.5 kW pair, 0.5 dB of imbalance means roughly 75 W of the total is being dissipated in the combiner instead of delivered, and that will not appear in a combined power reading taken at the flange. The test record and the sampling plan are described on the incoming inspection plan page.

Because this part is normally bought alongside a balun, an output transformer, a driver and a cold plate, the practical route is to consolidate the bill of materials against one delivery date. That is what the one stop RF supply page sets out, and at 1.5 kW the consolidation saves more time than any single line item saves money.

Questions buyers ask about the HXC50128

Is it 1500 W from one device? No. The row is 750 W times two, so it is a pair. Each half is 750 W at 58.75 dBm.

What is the top frequency? 200 MHz, written as 0.2 GHz. For 300 MHz take the 500 W pair or the 700 W pair on the next rows.

How much drive does it need? Not published. At 15 dB of gain it would be 47.5 W and at 20 dB it would be 15 W, a 5 dB spread that changes the driver chain.

Is the part internally matched? Nothing on the row says so. Assume the output network is the buyer's until the factory states otherwise.

How much heat at full power? 1227 W at 55 per cent efficiency and 808 W at 65 per cent, both calculated. The figure has to be measured before the cold plate is sized.