Contact Us

HX03140

Brand: Hisiwell
Hisiwell HX03140 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HX03140 — Discrete & Power Semiconductors | Superb Automation

HX03140

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HX03140 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HX03140: the same three gigahertz window with one hundred and eighty watts on the page

The HX03140 is the second member of the Hisiwell unmatched gallium nitride shelf that covers DC to 3 GHz on 28 V. The family index prints 140 W of saturation output, 14.5 dB of gain and 78 per cent drain efficiency in continuous wave. The product page calls it a 140 W part in the overview and then prints 180 W as the maximum saturated power with 81 per cent as the best drain efficiency. That is not a rounding difference, it is forty watts, so this page carries both figures and treats the lower one as the number to plan with.

140 W is 51.46 dBm and 180 W is 52.55 dBm. The two are 1.09 dB apart, which is the difference between a transmitter that meets a link budget and one that meets it with margin. Fourteen point five decibels of gain puts the drive at 36.96 dBm, 4.97 W, for the 140 W reading and at 38.05 dBm, 6.39 W, for the 180 W reading.

The part is flanged, so it bolts to a spreader rather than soldering to a carrier. Like every member of this shelf it is unmatched and the network sits on the customer board.

What the HX03140 documents print

Part classUnmatched gallium nitride HEMT power transistor
Frequency rangeDC to 3 GHz
Saturation output, family index140 W
Saturation output in dBm, calculated51.46 dBm
Maximum saturated power, product page180 W, 52.55 dBm
Difference between the two readings, calculated1.09 dB
Power gain, family index14.5 dB
Drive at the 140 W reading, calculated36.96 dBm, 4.97 W
Drive at the 180 W reading, calculated38.05 dBm, 6.39 W
Drain efficiency, family index78 per cent
Best drain efficiency, product page81 per cent
DC input at 78 per cent, calculated179.5 W
DC input at 81 per cent, calculated172.8 W
Drain current at 28 V, calculated6.41 A and 6.17 A
Dissipation at saturation, calculated39.5 W and 32.8 W
Drain rail28 V
Operating modeContinuous wave
BodyFlanged
MatchingUnmatched, external network on the customer board
Scattering parametersNot published in text
Load voltage at 50 ohm, calculated83.7 V RMS, 118.3 V peak at 140 W
Load voltage at the 180 W reading, calculated94.9 V RMS, 134.2 V peak
Output per GHz of band, calculated47 W per GHz at 140 W
Thermal resistance, junction to caseNot published
Gate bias point and quiescent currentNot published
Operating and storage temperatureNot published
Orderable addendum, marking and packingNot published
Shelf neighbour belowHX03120, 138 W, 15.3 dB, 81 per cent

Thirty nine watts of heat at the conservative reading

At 78 per cent and 140 W the DC input is 179.5 W and the dissipation is 39.5 W, which is nearly three times the number the same vendor prints for the 16 W part further up the shelf. At 81 per cent the same output leaves 32.8 W. If the part really delivers 180 W at 81 per cent the DC input is 222.2 W, the current 7.94 A, and the heat 42.2 W, so the heat barely moves while the output rises: that is what a higher power reading with a fixed efficiency does.

The supply follows the reading. Planning at 140 W needs 6.4 A at 28 V, planning at 180 W needs 8.2 A at the index efficiency. A supply built for six and a half amps and asked to deliver eight will sag on the pulse and take the gain down with it, which is often misread as a transistor problem.

The spreader is the other half. Forty watts in a flange of this size is a real thermal job: a copper or aluminium spreader with a thin interface and a fin stack that has an unobstructed path to ambient, and the case temperature measured at rated output in the enclosure rather than on an open bench.

At 140 W the load sees 118.3 V peak and at the 180 W reading 134.2 V peak. The output match, the connector and the isolator all have to be rated for the higher of the two if the higher one is what the factory confirms.

Choosing between HX03140 and its two neighbours

HX03120138 W15.3 dB81 per cent0.06 dB below, 0.8 dB more gain
HX03140140 W on the index, 180 W on the page14.5 dB78 per centReference point
HX04100F2126 W14.8 dB80.6 per cent0.46 dB below at 140 W, band to 4 GHz
HX2040185F185 W18 dB70 per cent1.21 dB above at 140 W, band starts at 2 GHz

Against the HX03120 the difference is one twentieth of a decibel, so the two are interchangeable on power and the decision is gain against efficiency. This part gives up 0.8 dB of gain and three points of efficiency, which on a continuous wave carrier is heat for nothing unless the 180 W reading is the one the factory will sign.

That is the real question. If the factory confirms 180 W, this part is 1.09 dB above its neighbour and the extra drive is 1.4 W, which is a driver change rather than a new stage. If the factory confirms 140 W, the two parts are the same transmitter and the cheaper or the shorter lead time wins.

The RF power transistor cross reference carries both readings side by side with a note on which document each comes from, and the RF component sourcing page covers how a factory confirmation is obtained before a schedule is committed.

Board notes that follow from an unmatched flange part

The gate bias is unpublished on this member as on the rest of the shelf. A negative rail with a clamp, sequenced before the drain, is the usual arrangement, and the quiescent point has to be set on the first article because no current is quoted in the documents.

Matching is on the customer board. With no scattering parameters printed, the input match for a 140 W die is either supplied by the factory on request or measured, and the output match has to survive 118 V peak at the conservative reading.

The drain feed wants a quarter wave choke and a capacitor bank at the flange, with the bulk capacitance behind the choke. At 6.4 A the feed trace and the choke wire carry real current, so the geometry is chosen for current first and for impedance second.

The flange bolts to the spreader, so the interface is a bolted joint with a specified flatness and a thin film. That joint, not the die, is usually where the temperature is lost.

The band is the other half of the decision. Three gigahertz at 140 W is 47 W per gigahertz, which is the highest density on the shelf below the 185 W member, and that density is what makes the 0.4 dB difference to the four gigahertz parts look small. A buyer who only needs 2.7 to 2.9 GHz pays for a decade of bandwidth in matching effort and gets nothing back, and a buyer who needs 3.5 GHz cannot use this part at all.

Questions buyers ask about HX03140

Is the part 140 W or 180 W? Both are printed by the vendor, 140 W in the overview and 180 W as the maximum saturated power. We quote the confirmed figure only after the factory answers, and until then the page carries both with the documents they come from.

What is the gain at the 180 W reading? The index prints one gain, 14.5 dB, and does not separate it by output level, so the drive at 180 W is a calculation from that single figure rather than a measured number.

Is there a compression point or a pulse rating? Neither is published. The mode is continuous wave and the only output figure is saturation.

Does the flange change the power? No. The flange is a thermal and mechanical choice, and the electrical row is the same.

How do we start? Send the band, the output at the connector, the duty, the ambient and the rail. We will get the power reading confirmed against the lot, quote from the factory schedule, and ship a sample with test data at the band edges.