Contact Us

LTM4650AIY#PBF

Brand: Analog Devices
Analog Devices LTM4650AIY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4650AIY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4650AIY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4650AIY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM4650AIY#PBF: A 50 A BGA Rail and the Four Figures That Decide How Much Board It Takes

The LTM4650AIY#PBF is the I grade BGA version of the LTM4650A: two channels of 25 A, or one of 50 A, from 4.5 V to 16 V in, with a 0.6 V to 5.5 V output range, plus or minus 1 percent total DC error and differential remote sense. The BGA is 16 mm by 16 mm by 5.01 mm, SAC305 balls at finish code e1, 3.8 g, MSL 3. Four figures decide how much board the part needs around it: the 1.5 C/W junction to case bottom, the 30 A current limit, the 15 mV output ripple with the published capacitor bank, and the 5 ms soft start.

Published values

ParameterValue
Input range4.5 V to 16 V
Output range0.6 V to 5.5 V per channel
Output current25 A per channel, 50 A single output
Total DC errorplus or minus 1 percent over line, load and temperature
Output ripple15 mV peak to peak at 500 kHz with 3 x 100 uF ceramic and 470 uF POSCAP
Current limit30 A typical per channel
Switching frequency500 kHz nominal, 250 kHz to 780 kHz programmable
Sync capture210 kHz to 290 kHz and 700 kHz to 860 kHz
Turn on5 ms with 0.01 uF on TRACK/SS, 10 mV overshoot
Load step30 mV peak deviation, 20 us settle
Thermal7 C/W junction to ambient, 1.5 C/W junction to case bottom
Package16 mm x 16 mm x 5.01 mm BGA, 144 balls, SAC305, 3.8 g, MSL 3
TemperatureI grade guaranteed -40 C to 125 C internal

Ripple, and why the capacitor list is part of the specification

The 15 mV peak to peak figure is published with three 100 uF ceramics and a 470 uF POSCAP, at 500 kHz and with no load. Change the bank and the number changes: a customer who fits one 47 uF ceramic instead of that bank is not comparing like with like, and the ripple on a 1.2 V rail can double before anything else goes wrong. On a 50 A rail the ripple current in the output capacitors is what sets their temperature, and their temperature is what sets how much capacitance is actually left at the end of a five year life.

Input side, the published inrush is 1 A with three 22 uF ceramics and 0.01 uF on TRACK/SS. Three 22 uF parts are 66 uF, which on a 12 V bus is the difference between a 1 A inrush and a hot plug event that trips the upstream fuse. Where the module sits more than a few centimetres from the bulk capacitor the input ceramic bank has to grow, and the datasheet's loop measurements assume it is close.

The 30 A limit against a 25 A rating

Twenty percent of headroom between the rating and the typical limit is a deliberate number. It has to cover the tolerance of the internal sense, the ripple current in the inductor at the operating point and the fact that a load step can be faster than the loop. A rail that regularly runs at 24 A to 25 A on a part with a 30 A typical limit is running with almost no margin, and the foldback behaviour under a short will engage later than the load current suggests.

For a load that has to be protected, the same family in the base version publishes 35 A typical against the same 25 A rating. That is the opposite direction: more headroom, later foldback, more stress on the inductor during a fault. Neither is wrong, but they are not interchangeable on a board that has been qualified against one of them.

Where 5.5 V out and 16 V in meet

A 5 V rail from a 12 V bus runs 41.7 percent duty, and from a 16 V bus 31.3 percent, both far from the minimum on time, so the frequency can stay at 500 kHz. A 0.6 V rail is the opposite case: at 16 V in the duty is 3.75 percent, and if the frequency were pushed up the on time would fall below the minimum. That is exactly why the A part accepts 250 kHz at the bottom of its range while the base part stops at 400 kHz.

The absolute maximum on VIN is 18 V against a 16 V operating top, so there are 2 V of transient headroom. On a 12 V bus with a hot plug event that is usually enough; on a 15 V bus with an inductive load switching nearby it is not, and a TVS or an electrolytic at the connector is cheaper than a module that has to be replaced.

Grade and second source position

The I grade is guaranteed over -40 C to 125 C internal, which covers the whole operating range the part is rated for. The Au finished LGA of the same family is the lower profile option at 4.41 mm and 3.6 g; the BGA here self centres on the balls and tolerates a paste print that the LGA land would not.

Because the footprint is shared with the LTM4620A and the LTM4630A, a 26 A or 36 A build of the same board is possible without a change to the copper. That is the practical answer to an allocation problem on the 50 A code: build the lower current modules and keep the board, rather than requalify a different family.

Two pages worth reading before a purchase order goes out are one stop BOM sourcing and how to reduce component cost; the first lists what else fits the socket, the second is the test sequence for a drop in, and defense grade components covers the case where the shortage is already on the line.

Two questions buyers ask

Can this part be used for a 5 V rail at 50 A? The voltage range allows it, but the current does not follow the voltage. 50 A at 5 V is 250 W, which is far beyond what one module dissipates comfortably: at 90 percent the loss would be 27.8 W against a 7 C/W package. The realistic ceiling for a single output is the 50 A at the low end of the output range, where the delivered power is 30 W to 90 W.

What is the smallest input capacitor bank that still meets the published ripple? The published figure assumes three 22 uF ceramics close to the pins. Fewer parts, or parts further away, add input ripple that the output filter then has to carry. On a 12 V bus a 66 uF ceramic bank within a centimetre of the module is the honest starting point, and the bulk electrolytic is what covers the cable inductance back to the supply.