ADR425BRZ
Product Specifications
ADR425BRZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADR425BRZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADR425BRZ as a 5.000 V reference: 2 mV initial and 3 ppm per degree C in the B grade
The ADR425BRZ is the 5.000 V member of the ADR420/ADR421/ADR423/ADR425 XFET family in the 8-lead SOIC body, B grade. It publishes 2 mV of initial error, 3 ppm per degree C drift, 3.4 microvolt peak to peak noise over 0.1 Hz to 10 Hz, 0.5 mA maximum quiescent current, 10 mA of output current, 50 ppm per 1000 hours of long-term stability, and a supply range of 7.0 V to 18 V. The XFET core is what buys the low noise at a quiescent current a buried Zener cannot reach.
Published values
| Parameter | Value |
|---|---|
| Output voltage | 5.000 V |
| Initial accuracy, B grade | 2 mV, which is 0.04 percent |
| Temperature coefficient | 3 ppm per degree C |
| Output noise, 0.1 Hz to 10 Hz | 3.4 microvolt peak to peak |
| Quiescent current | 0.5 mA maximum |
| Output current | 10 mA |
| Supply range | 7.0 V to 18 V |
| Long-term stability | 50 ppm per 1000 hours |
| Load regulation | 70 ppm per mA |
| Line regulation | 35 ppm per V |
| Output hysteresis | 40 ppm typical |
| Temperature range | -40 to +125 degrees C |
Adding the four error terms a converter actually sees
2 mV of initial error is 26.2 codes of a 16-bit converter on a 5 V full scale. Drift at 3 ppm per degree C over 165 degrees is 2.475 mV, 32.4 codes. Long-term stability of 50 ppm per 1000 hours is 250 microvolt, 3.3 codes, and it is not cumulative in the way a linear drift would be.
Load regulation of 70 ppm per mA is the term that catches people out: pulling 5 mA from the reference moves it by 350 ppm, which is 1.75 mV and 23 codes, larger than the drift over a 100 degree excursion. A reference input that draws current through a long trace has a load regulation problem before it has a noise problem.
Line regulation of 35 ppm per V over a 7 V to 18 V input span is 385 ppm, 1.9 mV, so the input rail's own tolerance enters the error budget through this term as well.
Where the 7 V to 18 V window comes from
A 5 V output needs 2 V of headroom in this family, so 7 V is the floor. A 12 V industrial bus sits comfortably inside the window, and 18 V is the ceiling rather than a target: at 18 V and 10 mA the part dissipates 130 mW, which is inside the SOIC but adds a die temperature rise that the drift figure then follows.
A 5 V system cannot use this part as its reference without a higher rail, which is the same constraint the ADR02 family carries and the reason both are usually fed from 12 V.
XFET noise against a buried Zener
3.4 microvolt peak to peak over 0.1 Hz to 10 Hz is 0.045 codes of a 16-bit converter on 5 V, so the low frequency noise is not what limits the measurement. A buried Zener of the same accuracy class runs an order of magnitude noisier and needs several times the supply current.
The 40 ppm typical hysteresis is the term that matters after a thermal cycle: it is a shift that does not come back when the temperature returns, so a system calibrated cold and used hot keeps a 200 microvolt offset after the first cycle unless it is recalibrated.
Where a customer needs a second position on this part, the ADI second source page is the starting point, component lead time solutions sets out the checks a substitution has to pass, and how to verify a drop in replacement is the short lead time route we quote against.
Two questions buyers ask
Is ADR425BRZ the same as the ADR425ARZ? Same voltage, same die family and different guaranteed limits. The B grade is 2 mV of initial error against the A grade's wider window, and a purchase order that does not carry the grade letter does not specify which one arrives.
What is the difference between this and the ADR02? Topology and noise. This is an XFET reference with 3.4 microvolt of low frequency noise and 0.5 mA of quiescent current, against a band gap part with 10 microvolt of noise and a wider supply range.