Contact Us

AD8552ARZ

Brand: Analog Devices
Analog Devices AD8552ARZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD8552ARZ — Analog & Mixed-Signal ICs | Superb Automation

AD8552ARZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD8552ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD8552ARZ: dual zero-drift amplifier with 5 microvolts maximum offset

The AD8552ARZ is a two channel zero-drift amplifier in an 8-lead SOIC_N with a 5 uV maximum offset and 0.04 uV/C maximum drift over -40 to +125 C, rail-to-rail input and output, and 1.5 MHz of bandwidth for 850 uA per amplifier. It is the part to specify when the offset has to hold without a calibration step and the signal is slower than a few hundred kilohertz.

Published values

ParameterValue
Offset voltage1 uV typical, 5 uV maximum per amplifier
Offset voltage drift0.005 uV/C typical, 0.04 uV/C maximum
Input bias current10 pA typical, 50 pA maximum
Supply current per amplifier850 uA typical, 975 uA maximum at 5 V
Gain bandwidth1.5 MHz at 5 V, 1 MHz at 2.7 V
Slew rate0.4 V/us at 5 V, 0.5 V/us at 2.7 V
Voltage noise density42 nV/root Hz at 5 V, 75 nV/root Hz at 2.7 V
Noise, 0.1 Hz to 10 Hz1.0 uV p-p
CMRR and PSRR120 dB minimum each
Open loop gain125 dB minimum, 145 dB typical
Overload recovery0.05 ms typical, 0.3 ms maximum
Supply range2.7 V to 5.5 V single supply

Adding the offset and the drift gives the error a customer will measure

Five microvolts at 25 C plus 0.04 uV/C across the 165 C span of the temperature range is 6.6 uV, so the worst case total is about 12 uV over the full range, and that is a number a 16-bit system can live with: one code at 5 V and 16 bits is 76 uV. The same arithmetic on a 6 mV general purpose part gives 6.7 mV, which is 88 codes at 16 bits and the reason the two parts are not interchangeable in a measurement channel.

The cost of zero drift is current and bandwidth

975 uA maximum per amplifier is five times what the AD8539 draws for a tenth of the offset, and the bandwidth is 1.5 MHz against 430 kHz. Put the two facts together and the choice becomes a power question: a two channel battery instrument with a 1 mA total budget can afford one of these and not two, and a mains powered instrument does not care. The AD8539 lists the same 1 uV class offset for a fifth of the current when the signal stays under 100 kHz.

Behaviour at 2.7 V

Two specifications move when the rail drops to 2.7 V: the noise density rises from 42 to 75 nV/root Hz and the bandwidth falls from 1.5 MHz to 1 MHz. Neither is a defect, they are the cost of running the input stage on a smaller headroom, but a circuit that was characterised at 5 V and then powered from a lithium cell will measure differently. Re-check the noise budget at the rail the product actually uses.

Recovery after a saturated input

A sensor that rails the amplifier, which happens on every power up of a bridge with an uncharged excitation, needs 0.3 ms maximum to come out of overload. In a scanning system that is 300 us of dead time per channel after a fault, and it belongs in the timing budget rather than being discovered on the bench.

The pages that answer this most often are the amplifier cross reference for the family alternatives, the ADI second source page for the acceptance test, and how to verify a drop in replacement for the case where a replacement has to be fitted before the next build.

Two questions buyers ask

How does the AD8552ARZ differ from the AD8572ARZ? Both are zero-drift duals with a 5 uV maximum offset, 850 uA per amplifier and 1.5 MHz of bandwidth. The published noise differs: 42 nV/root Hz here against 51 nV/root Hz on the AD8572, and 1.0 uV p-p against 1.3 uV p-p at low frequency. Where noise is the deciding term, check both sheets before fixing the part number.

Can the input go to the negative rail? Yes, the input and the output both reach the rails, which is what allows a single supply bridge or thermocouple front end without a negative rail.