AD7865ASZ-1
Product Specifications
AD7865ASZ-1
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD7865ASZ-1 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD7865ASZ-1: Four Channels Sampled Together at 14 Bits, Then Converted One at a Time
The AD7865 takes the approach that matters for motor control and power measurement: four track and hold amplifiers capture all four inputs at the same instant, and then a single 2.4 microsecond successive approximation converter reads them one after another through a multiplexer. The relative phase between the four signals is preserved because the sampling instant is common, and the conversion time per channel is what sets the scan rate rather than the sampling instant. It operates from a single 5 V supply, dissipates 115 mW typical, drops to 15 uW in its power saving mode, and comes in a 44-lead plastic quad flat pack.
Two and a half microseconds per channel, 0.35 microseconds to acquire
The track and hold acquisition time is 0.35 microseconds and the conversion is 2.4 microseconds per channel, so a full four channel scan takes about 11 microseconds including the acquisition window, which fits comfortably inside a 50 microsecond pulse width modulation period. That is the arithmetic a motor drive cares about: the currents have to be captured at a defined point in the switching cycle and the results have to be available before the next cycle is calculated. The channel sequence can be selected in hardware or over the bus, which means a controller can convert a subset of the four, for instance only the two currents during one period and all four when a fault is being investigated.
Five input ranges and one 5 V supply
The part accepts plus or minus 10 V, plus or minus 5 V, plus or minus 2.5 V, 0 V to 5 V and 0 V to 2.5 V, selected by the model suffix in the ordering guide rather than by a register. On the plus or minus 10 V range the 20 V span divides into 16384 codes of 1.22 mV, and on the 0 V to 2.5 V range the 2.5 V span gives 153 uV per code. A buyer ordering this code should confirm the suffix against the reel or the invoice, because the same 44-lead outline carries every range and a wrong suffix is a range error that no calibration can correct.
| Parameter | Value | What it decides |
|---|---|---|
| Resolution | 14 bits | 1.22 mV per code on a 20 V span |
| Channels | Four, simultaneously sampled | Phase between channels preserved |
| Conversion time | 2.4 microseconds per channel | Full scan about 11 microseconds |
| Acquisition time | 0.35 microseconds | Fast enough for one scan per pulse period |
| Input ranges | Plus or minus 10 V, 5 V, 2.5 V, 0 to 5 V, 0 to 2.5 V | Selected by model suffix, not by a register |
| Overvoltage | Protection on the analogue inputs | A faulted channel does not destroy the part |
| Reference | 2.5 V on chip | No external reference part |
| Supply | Single 5 V, plus a separate drive supply | Interfaces to 3 V processors |
| Power | 115 mW typical, 15 uW in power saving mode | Idle periods cost almost nothing |
| Interface | High speed parallel port with a first data flag | Host can read results as they arrive |
| Package | 44-lead plastic quad flat pack | 0.3 square inches for four channels |
Simultaneous sampling is the whole point
In a three phase drive the three currents sum to zero only if they are measured at the same instant; sampling them 2.4 microseconds apart during a switching transition gives three numbers whose sum is not zero and a torque calculation that is wrong. The same argument applies to power measurement, where the voltage and current of a phase have to be captured together for the product to mean anything. That is why the part carries four track and hold amplifiers rather than one fast sample and hold in front of a multiplexer: the cost is silicon area, and the benefit is that the phase information survives.
Where the part fits
Alternating current motor control, uninterruptible power supplies, industrial power meters and monitors, data acquisition systems and communications are the named applications. The 115 mW figure and the 15 uW power saving mode together make it usable in a battery backed instrument that samples in bursts. A product that needs more than four simultaneous channels has to run two parts with a shared convert start, and a product that needs more resolution at the same simultaneous sampling should look at the 16-bit family members with the same architecture. For an overview of converter options, the ADC and DAC cross reference page lists the family, the ADI part second source page covers alternates, and the incoming inspection plan page covers range and grade checks on receipt.
The first data flag removes a status read
The part brings the first channel result to a dedicated flag pin, so the host can start reading as soon as that flag asserts instead of polling a status register or timing the conversion from the convert pulse. On a four channel scan of about 11 microseconds, saving a status read of even 1 microsecond is nine percent of the scan budget, and it removes the corner case where a slow host reads a register that has already been overwritten. The same flag is what makes a two channel subset practical at high repetition rates, since the host knows which of the four results is arriving without having to track the sequence in firmware.