AD5421BCPZ-REEL7
Product Specifications
AD5421BCPZ-REEL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD5421BCPZ-REEL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD5421BCPZ-REEL7: a 16-bit loop DAC where 0.05 percent total error is 8 microamps and 33 codes
What the part does
The AD5421BCPZ-REEL7 is a loop powered, 16-bit, serial input, 4 mA to 20 mA converter from Analog Devices in a 32-lead LFCSP. It draws its own supply from the current loop, so the transmitter needs no separate rail, and it includes a regulated output from 1.8 V to 12 V that can power the sensor and the microcontroller alongside it.
The loop voltage window is 5.5 V to 52 V, the quiescent current is 300 microamps maximum, and the output ranges are pin selectable between 4 mA to 20 mA, 3.8 mA to 21 mA and 3.2 mA to 24 mA, with NAMUR compliant alarm currents at 3.2 mA downscale and 22.8 mA or 24 mA upscale. The serial interface runs to 30 MHz, and the part keeps HART communication working without degrading the specified performance.
Error budget in the units a loop actually uses
Total unadjusted error of 0.05 percent over a 16 mA span is 8 microamps, and one code of the 16-bit word is 244 nanoamps, so the specified error is 32.8 codes wide. Integral nonlinearity of 0.0035 percent of full scale is 2.29 codes, which means the linearity is an order of magnitude better than the total error and the offset and gain terms are what the calibration has to remove.
Output temperature coefficient of 3 ppm per degree Celsius over the 145 degree industrial span is 435 ppm, or 0.0435 percent, which is 6.96 microamps. That is close to the total error figure, so a transmitter calibrated at 25 Celsius will drift most of its budget by the time it sits in a hot cabinet.
| Resolution | 16 bits, monotonic |
|---|---|
| Output ranges | 4 to 20 mA, 3.8 to 21 mA, 3.2 to 24 mA, pin selectable |
| Total unadjusted error | 0.05 percent maximum, 8 microamps |
| Linearity | 0.0035 percent of full scale, 2.29 codes |
| Output drift | 3 ppm per degree Celsius typical |
| Quiescent current | 300 microamps maximum, 7.5 percent of the 4 mA floor |
| Loop voltage | 5.5 V to 52 V |
| On-chip reference | 4 ppm per degree Celsius maximum, 1.22 V and 2.5 V |
| Regulated output | 1.8 V to 12 V to power the rest of the transmitter |
| Interface | SPI compatible to 30 MHz, FAULT pin, fault register readback |
| Package and range | 32-lead LFCSP or 28-lead TSSOP, minus 40 to plus 105 Celsius |
Power inside the transmitter, not in the loop
At a 52 V loop with a 250 ohm sense resistor and 4 mA of current, the part and the transmitter dissipate about 204 mW, because 51 V of the loop is dropped across them. That heat sits in the same sealed head as the sensor, and it is the reason the 12 V regulated output is used sparingly rather than to run a display. A 24 V loop halves the figure and is the common industrial choice for that reason.
The 300 microamps of quiescent current is 7.5 percent of the 4 mA floor, which leaves 3.7 mA for the sensor and the processor. A transmitter that budgets the full 4 mA for its own circuitry will find the loop cannot reach its low alarm value, and the failure looks like a calibration error rather than a current budget error.
Where it is used
- Smart pressure, level and flow transmitters that must run on the loop alone.
- HART networks where the converter has to leave the loop impedance clean for FSK.
- Temperature transmitters with a 12 V regulated sensor supply.
- Valve positioners that need NAMUR alarm currents for a safe failure state.
Buying this order code
The BCPZ-REEL7 suffix is the LFCSP on a 7-inch reel, which suits a build with a reflow profile written for a 5 mm by 5 mm body. Buyers ask about the HART compatibility statement, the loop voltage range against their barrier, and the date code. The first is a datasheet statement rather than a qualification, so a customer with a certified HART stack should still run their own test.
Alternative loop converters are listed on the ADC and DAC cross reference, the checks before accepting a substitute are on drop in verification, and the family index is on the analog and mixed signal IC page.
Request Quote — In Stock, 100% New & Original, Full Warranty