Contact Us
  • Home
  • BLOG
  • What Cpk Should a PCB Supplier Hold on Hole Position?

What Cpk Should a PCB Supplier Hold on Hole Position?

Ask for Cpk 1.33 on plated hole position in X and Y, and 1.67 where a hole takes a press-fit pin or sits in a 0.4 mm pitch BGA field. The index only means something when it is tied to the tolerance you are buying and to the stack it was measured on, so ask for the tolerance, the sample and the stack in the same answer.

Our standard hole position tolerance is plus or minus 0.075 mm, which is a tolerance width of 0.150 mm. Cpk 1.33 needs a standard deviation of 18.8 microns or less, Cpk 1.67 needs 15.0 microns, and a line running at 25 microns sits at Cpk 1.0. That is the whole argument: the difference between a comfortable board and a marginal one is a few microns of drill scatter, not a document.

Why the index on each axis is not the whole story

A drilled hole carries two independent error fields. Acceptance is a circle of 0.075 mm radius around the nominal point, not a square. With 18.8 microns of scatter per axis, the per axis reject rate is 63 ppm, but about 350 ppm of holes fall outside the circle. At 25 microns per axis the circle rejects roughly 1.1 percent, one hole in ninety, while each axis on its own still reads as acceptable. That is the gap between a certificate and a board that passes at the press.

The same logic explains how a shop reports a good number and still ships a panel that fails. If the study is run on outer layer pads, it measures the drill against the surface pattern. The hole that fails is on layer 3, where the registration of a 20 layer stack decides how much annular ring is left after plating.

Where the scatter comes from

Drill position is set by the machine, the entry and exit material, the stack height and how many panels run under one spindle. It is then moved by lamination shrink, by oxide and etch, and by plating. On a multilayer stack each press cycle adds its own shift, which is why a 20 layer board with seven press cycles carries a wider registration window than a 6 layer board. Our window for layer to layer registration is 0.025 to 0.06 mm, and the annular ring minimum is 3.5 mil on 1 oz copper and 4.5 mil on 2 oz.

The effect is cumulative and it goes the wrong way. A hole 20 microns off centre on the outer layer has already used two thirds of the annular ring on an 8 mil pad before the inner layer shift is counted. That is the case a coupon figure does not show, because the coupon has no component behind it and no inner layer network to clear.

Three ways a capability claim goes wrong

The first is an index without its tolerance. A line at Cpk 2.0 against plus or minus 0.100 mm is running at 16.7 microns, which is worse than a line at Cpk 1.33 against plus or minus 0.050 mm at 12.5 microns. The looser drawing flatters the number, and the tighter drawing is the better process.

The second is a machine study sold as a process study. Thirty holes from one panel, drilled in one setup, measure the machine, Cm and Cmk, not the process. A process figure needs subgroups taken across shifts and lots, 125 values or more, and a note saying whether it is Cpk on a stable process or Ppk over all the data. Both are legitimate. They answer different questions, and a defence or medical auditor usually wants the longer record.

The third is a coupon cut from the panel edge. The coupon is drilled with the panel and travels with it, which is correct, but the panel edge is where the press is stiffest and registration is best. Ask where the coupon is taken from, and whether the values come from the finished board or from the coupon. On a 20 layer stack the two answers differ by more than the tolerance margin.

What a buyer can check in an hour

Ask for the last three capability studies on the same stack, not the same machine, and compare the sample sizes and the dates. Then ask for one X and Y scatter plot. A process with a good index but a mean sitting 15 microns off nominal is one drill consumable change away from failing, and the plot shows that at a glance where the index hides it. Finally, ask what happens at incoming inspection: a shop that probes every hole has a different risk profile from a shop that samples, and both can quote the same index.

How to write the requirement so it can be met

Name the feature precisely: plated hole position, not pattern position in general. Give a tolerance per hole diameter class, because a 0.3 mm via and a 1.6 mm connector hole do not carry the same scatter. State the acceptance zone as a diameter, so nobody compares a circle with a square. Say how many holes, panels and lots the study covers, and whether the readings come from the finished board. Then set the index, 1.33 general and 1.67 for press-fit and fine pitch.

If the drawing also fixes drill size, plating thickness and annular ring, the shop has three variables it can trade against each other. Fixing all three and demanding 1.67 is a different order from demanding the index alone, and it deserves a different quotation rather than a yes.

What we hold

On the FR-4 line the hole position tolerance is 0.075 mm, plated through holes are 0.075 mm, and press-fit holes tighten to 0.05 mm. Mechanical drilling runs 0.15 to 6.35 mm, laser drilling 0.075 to 0.15 mm, aspect ratio 10:1 on the standard line and 25:1 on the high layer line, up to 68 layers, plating 20 microns and above. Position and registration data for a lot ship with the boards, and on request we send the raw X and Y deviations with the sample plan, so your quality team can compute the index instead of reading ours. Parameter detail sits on PCB capability and the FR-4 line on FR-4 process parameters.

SUPERB PCB builds to print, so the tolerance and the index come from your drawing and your procedure. Where a stack cannot hold 1.67 on the hole table you sent, we say so in the quotation with the reason, instead of letting the first lot speak for itself.

Next step

Send the stack, the hole table with a tolerance per diameter, the layer count and a note on which holes take a press-fit pin. We will come back with the index we can hold on that stack and the sample plan behind it. Defense builds carrying this level of documentation run through defense and radar PCBA. For assembly side evidence, SUPERB Assembly records the same lot identity from incoming laminate to the test result.

Need a quote or a review of your hole table against these limits? pcba@superb-tech.com · WhatsApp +86 133 9608 1443