Texas Instruments UCC28056BDBVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

UCC28056BDBVR — Power Management & Signal Chain | Superb Automation

UCC28056BDBVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The UCC28056BDBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

UCC28056BDBVR: six pin transition mode PFC controller with burst mode

UCC28056BDBVR is a power factor correction controller that runs a boost stage in transition mode at full load and slides into discontinuous conduction at light load in a SOT-23 (DBV) body of 6 pins. It drives a boost stage up to 300 W with a sinusoidal input current close to unity power factor, and it moves into a reduced frequency discontinuous mode as the load falls, so the PFC can stay on at no load instead of being switched off by a relay or a second converter.

Order code and package

Order code read outUCC28056 B DBV R: device UCC28056 revision B, DBV six pin SOT-23, R large tape and reel
PackageSOT-23 (DBV), 6 pins
Carrier in the vendor addendumThe DBV rows are published at 3000 pieces on a large reel and 250 pieces on a small reel, with A suffix rows beside them
Moisture levelLevel 1, 260 degrees unlimited floor life
Lead finishNickel palladium gold on the rows that state a finish, with a call vendor note on some
Operating temperatureminus 40 to plus 125 degrees
Part marking805A on the published rows

Electrical parameters that decide the application

Supply start11 V typical rising, 10.65 V minimum, with turn off at 8.85 V and 1.5 V of hysteresis
Undervoltage blanking35 microseconds of turn off blanking, which rides through a line notch without a restart
Start up current46 uA before start up, so the bias resistor chain from the rectified line can be small
Run current2.2 mA typical with the gate output unloaded
Burst off current132 uA from VCC during a burst off period, which is the number that sets no load input power
Gate drive high level13.7 V typical at a 25 V supply, current limited rather than rail to rail
Gate pull up and pull down16 ohm pull up and 4.6 ohm pull down, an asymmetric drive that turns the FET off faster than it turns it on
Rise and fall time34 ns and 15 ns into a 1 nF load
Power capabilityThe vendor rates the controller for a boost stage up to 300 W
Standby resultUnder 80 mW at 230 V AC in a PFC plus LLC system with the UCC256403 or UCC256404 and the UCC24624
Valley switchingDrain valley synchronised turn on, which removes the second winding on the boost inductor
Absolute maximum36 V on VCC, 7 V on the zero crossing and current sense pin, 150 degrees junction

Family members and how they differ

UCC28056Bthe part on this page, in the six pin SOT-23 with the B revision
UCC28056Athe earlier revision, listed in the same addendum rows at the same reel sizes
UCC28064Athe vendor names it as an alternative PFC pairing for the LLC controller, for higher power two phase work
UCC256403 and UCC256404the LLC controllers used in the sub 80 mW standby reference
UCC24624the dual synchronous rectifier controller that completes the reference secondary side

Points to check before this part goes on a BOM

The point of this controller is that the PFC never has to be turned off. A conventional transition mode part is switched out of the circuit at light load by a relay or an auxiliary converter, because its own consumption and switching loss would break the standby budget. Burst mode with soft entry and soft exit keeps the stage alive at 132 uA of VCC current, which is why a 230 V AC adapter can sit under 80 mW with the PFC still connected to the line.

Mixed mode operation is a frequency behaviour, not a mode pin. At full load the inductor current returns to zero and the switch turns on again at the valley, which is transition mode and gives the lowest loss. As the load falls the controller allows the current to stay discontinuous for several cycles and drops the switching frequency, which is what keeps efficiency up at light load. Nothing needs to be reconfigured between the two, and the crossover is invisible on the bench apart from the frequency falling.

Valley synchronised turn on is the feature that saves a winding. Older circuits used a second winding on the boost inductor to sense when the drain voltage had fallen, so the switch could be turned on at the minimum. This part derives the valley from the gate and current sense signals instead, which removes a magnetic component and two solder joints from the board, and it is one of the reasons a 300 W stage fits in a six pin controller.

The gate drive is deliberately asymmetric. A 16 ohm pull up and a 4.6 ohm pull down means the FET turns off roughly three times faster than it turns on, which reduces the turn off loss in a boost where the switch carries the full inductor current, and it also keeps the drain rise slow enough on turn on to limit the reverse recovery of the boost diode. The external gate resistor, if one is used, has to be chosen with that asymmetry in mind.

The 35 microsecond undervoltage blanking window exists for real line conditions. A short notch or a dip on the AC line would otherwise drop VCC below the 8.85 V stop threshold and restart the controller, which produces a visible blink on the output and an audible click. Blanking the turn off for 35 microseconds means the controller rides through the notch and only stops on a genuine loss of input.

Where this order code fits

Used in AC to DC front ends where standby power and power factor both have to meet a standard: monitor and laptop adapters, TV power boards, LED lighting drivers, set top boxes, audio systems and industrial supplies that must hold EuP Lot 6 Tier 2, CoC version 5 Tier 2, Energy Star 6.1 and DoE Level VI. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the One Stop BOM Sourcing page.

Questions buyers ask

Does the PFC stay on at no load? That is the intent. Burst mode holds the stage alive at 132 uA of VCC current, and the vendor quotes under 80 mW at 230 V AC for a complete PFC plus LLC system, so no relay or auxiliary converter is needed.

What is the maximum power? 300 W for the boost stage according to the vendor. A higher power stage uses a two phase controller such as the UCC28064A, which the vendor names as the pairing for the LLC controller.

Why does it not need a second winding on the inductor? Because the valley is derived from the gate drive and current sense signals rather than from an auxiliary winding. That removes a magnetic component and simplifies the inductor specification.

Is the B revision a different pin out? No. The B revision keeps the six pin SOT-23 body and the same pin functions. It appears in the same large and small reel rows as the A revision, so either can be ordered against a board that was drawn for the family.

What happens during a line notch? The undervoltage turn off is blanked for 35 microseconds, so a short notch does not stop the controller. A longer loss of input does stop it, and the restart then follows the 11 V start and 8.85 V stop thresholds.

What inductor and diode does a 300 W stage use? A boost inductor sized for the transition mode ripple at low line and a silicon carbide or fast recovery diode rated for the 400 V output. The controller does not specify them, so the magnetic and diode choice follows the power level.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.