The TPSM861252RDXR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPSM861252RDXR: a 1 A module that puts the inductor, the bootstrap capacitor and the divider inside one 3.3 mm by 4 mm body
The TPSM861252RDXR is a 1 A synchronous buck power module with a 3 V to 17 V input and an adjustable output from 0.6 V to 10 V. What separates it from a controller plus external parts is what sits inside the package: the high side and low side MOSFETs at 55 milliohm and 24 milliohm, a shielded inductor, the bootstrap capacitor, and the feedback divider with its feedforward capacitor. A 24 V industrial bus drops to 5 V or 3.3 V with one part, one input capacitor and one output capacitor, and the board area taken is 3.3 mm by 4 mm by 2 mm.
The device runs D-CAP3 control, which means no external compensation network and stable operation with low ESR ceramic output capacitors. Start-up is fixed at 1.6 ms typical and the enable pin compares against a 1.2 V precision threshold, so a resistor divider from the input sets a clean lockout instead of relying on the internal UVLO alone. The 252 member of the family is the Eco-mode version: it drops into pulse skipping at light load and holds the no load input current at 100 microamps, which is the version to pick when a rail stays alive through a standby window.
Key electrical data for the TPSM861252RDXR
| Input range | 3 V to 17 V operating, UVLO wakes at 2.9 V typical and shuts down at 2.7 V with 200 mV of hysteresis |
| Output | 0.6 V to 10 V adjustable, feedback 594 mV to 606 mV at 25 C and 591 mV to 609 mV from 0 C to 65 C |
| Current | 1 A continuous, valley current limit 1.5 A minimum, 2.3 A typical and 3.1 A maximum |
| Switches | 55 milliohm high side and 24 milliohm low side at 25 C with 5 V in, high side rising to 68 milliohm at 3 V in |
| Switching | 1.4 MHz nominal, minimum on time 60 ns, maximum duty 95 percent |
| Quiescent | 100 microamps no load in Eco-mode against 370 microamps in the forced continuous versions, 2 microamps shutdown |
Package, marking and reel data
| Body | RDX, 7 pin QFN-FCMOD, 3.30 mm by 4.00 mm by 2.00 mm, wettable flank pads on the side |
| Reel | 3000 pieces on a 330 mm reel, 12.4 mm carrier, 4 mm pitch, pocket 3.6 by 4.3 by 2.3 mm, quadrant Q1 |
| Finish | NIPDAU, moisture level 2 at 260 C, one year floor life on the published row |
| Marking and grade | 861252 on the top, junction rated -40 C to 125 C |
Where the 1 A module belongs on a control board
Three rails on a typical industrial controller fit this part without a second thought: the 3.3 V rail for an MCU and its logic, the 5 V rail for a CAN transceiver and a sensor front end, and a 1.2 V or 1.8 V core rail from the same 12 V or 24 V bus. The 95 percent duty cycle is the number that keeps the third case alive, because a 5 V input feeding a 3.3 V rail sits at 66 percent duty and a 5 V input feeding a 4.5 V rail sits at 90 percent, both inside the window, so the module keeps regulating instead of dropping out when the bus sags.
The parts that surround the module decide whether the thermal budget holds. A 1 A load at 12 V in and 3.3 V out dissipates about 0.55 W inside the package, split between conduction and switching, and the RDX body on two square inches of copper sits well inside the 125 C junction limit. The input capacitor has to be a 10 microfarad ceramic within a few millimetres of the VIN pin, because the module switches at 1.4 MHz and the loop area sets the input ripple. The output capacitor is chosen for the transient, not for the ripple, since the D-CAP3 loop reacts within a switching cycle. Our power management cross reference page lists the second sources we keep in stock for this family.
Buyer questions on the TPSM861252RDXR
Is the divider really inside the module? Yes on the 253 member, which is the fixed 3.3 V version, and no on the 252, which brings the feedback pin out so a resistor pair sets the output. That is the reason the two codes are not interchangeable on a board that already has its own divider.
Can the module start into a pre-biased output? It can. The vendor states support for start-up with a pre-biased output voltage, which matters on a board where a second rail or a load switch holds the node up before this converter enables.
What happens on a short circuit? The valley current limit trips at 2.3 A typical and the part retries in hiccup mode on an undervoltage event, so the average current into a short stays low instead of sitting at the limit.
Availability and cross reference
The published row is 3000 pieces on a large reel. Small quantities for a pilot build come from a partial reel, and the date code on that partial reel is what decides whether the lot is usable for a medical or automotive build. We record the reel label and the moisture level on every kitting order for this body, because a level 2 part that has been open for a month needs a bake before reflow and the assembler will not know that from the box alone. Lead time on the 252 and the 253 moves independently, and our component lead time solutions page explains how we hold one code against the other when a customer cannot change the rail voltage.