TPS715A01DRVR
Product Specifications
TPS715A01DRVR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS715A01DRVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS715A01DRVR adjustable regulator from 1.205 V to 15 V
The TPS715A01DRVR is the adjustable member of the TPS715A family, an 80 mA linear regulator that runs from 2.5 V to 24 V and sets its output with an external divider anywhere from 1.205 V to 15 V. The 01 suffix is the adjustable row, and the fixed rows of the same family cover 1.8 V to 5 V. Quiescent current is 3.2 microamps at the full 80 mA load, which is low enough that the regulator is not the largest drain in a product that sleeps, and dropout is 650 mV typical at 80 mA.
The body on this order code is the DRV, a six pin WSON of 2 mm by 2 mm. The family also ships in the DRB, an eight pin VSON of 3 mm by 3 mm, which is the body to use when the dissipation is the limiting factor. The document notes that the DRB is available as a non magnetic package for medical imaging, which is the reason that option exists: a part with magnetic material in it cannot sit inside an MRI bore.
The part has an internal soft start on the current chip, which limits the inrush into the output capacitor at enable, and a current limit that protects it against a shorted load. The reference is 1.205 V, so a divider with equal resistors gives 2.41 V, and the divider current is the main thing a low quiescent board has to size deliberately, because a 100 kilohm divider at 2.4 V adds 24 microamps, seven times the regulator's own quiescent current.
Key parameters from the SBVS047I document
| Input range | 2.5 V to 24 V |
| Output range | 1.205 V to 15 V set by an external divider on this order code |
| Output current | 80 mA |
| Quiescent current | 3.2 microamps typical at 80 mA of load |
| Dropout | 650 mV typical at 80 mA |
| Reference | 1.205 V, the floor of the adjustable output range |
| Protection | Overcurrent limit and thermal protection |
| Start-up | Internal soft start on the current chip limits inrush |
| Packages | DRV six pin WSON 2 mm by 2 mm and DRB eight pin VSON 3 mm by 3 mm |
| Temperature | Junction range of minus 40 to plus 125 degrees |
| Order code | TPS715A01DRVR, WSON body, active in the vendor addendum |
What the adjustable row changes about the order
An adjustable regulator moves the voltage decision from the factory to the board. That is a benefit when a rail has to be trimmed to a load that has its own tolerance, and a liability when the divider is copied from a reference circuit without checking the reference voltage. The 1.205 V reference is higher than the 0.8 V and 0.6 V references used on newer parts, so a divider taken from one of those gives an output about 50 percent too high.
The divider also sets the load regulation at light load. The regulator's own quiescent current is 3.2 microamps, so a divider that draws 24 microamps dominates the standby budget, and a divider that draws 2.4 microamps through very large resistors is more sensitive to board leakage and to moisture. Somewhere between 1 and 10 microamps of divider current is the practical compromise on a low power board.
Where this part fits
Home and building automation, retail terminals and payment equipment, grid infrastructure monitors, medical instruments and lighting controls. The common thread is a 12 V or 24 V bus and a small load that needs a clean rail, often at a voltage that no fixed row offers. The non magnetic DRB option is what makes the family usable inside imaging equipment. Substitution notes for the adjustable rows are under power management cross reference, and the divider and reel checks are in incoming inspection plan.
What to check before a purchase order
Check the divider against the 1.205 V reference and against the load tolerance. A 5 V output needs a ratio of about 3.15, and a divider that rounds that to 3 gives 4.82 V, which is outside the 5 percent window of most 5 V loads. Also check the divider current at the lowest expected output, since the current falls with the output voltage and the loop needs enough current to stay stable.
Check the dissipation for the chosen body. At 24 V in and 3.3 V out with 50 mA of load the part burns 1.03 W, which the WSON of 2 mm by 2 mm cannot hold but the 3 mm by 3 mm VSON can with a copper pour. A board that uses the small body because it fits will discover the limit as a thermal fold back that looks like a load fault.
Check that the output capacitor is inside the stable range and that the soft start is long enough for the load. A 1 microfarad output into a 50 mA load starts in well under a millisecond, while the same regulator into a 100 microfarad load and a 20 mA load takes long enough that a supervisor on the rail may release reset early.
Questions that come up on this part
Can the output go below 1.205 V? Not with this part. The reference is the floor, and a lower rail needs a different part with a lower reference.
Is the 3.2 microamp figure the current at no load? The document quotes it at 80 mA of load, which is a stronger statement than a no load figure: the regulator does not give up its quiescent current as the load rises.