The TPS563252DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS563252DRLR: 3 A buck converter that drops to 100 uA of supply current at light load
TPS563252DRLR is a 3 A synchronous step-down converter in the six pin DRL body that runs from 3 V to 17 V, switches at 1.2 MHz in continuous conduction and enters Eco-mode below a load threshold to hold 100 uA of supply current in a SOT-563 body of 6 pins. The TPS563252 is the Eco-mode member of the TPS56325x pair and shares its package, pin out and power stage with the forced continuous TPS563257. Input is 3 V to 17 V, output is 0.6 V to 10 V, the reference is 600 mV and the switches are 55 milliohm and 24.3 milliohm. Below a light load threshold the converter stops switching in the usual way and delivers pulses as the output falls, which is what brings the supply current down to 100 uA instead of 370 uA.
Order code and package
| Order code | TPS563252DRLR |
| Input voltage | 3 V to 17 V |
| Output voltage | 0.6 V to 10 V |
| Rated output current | 3 A |
| Reference voltage | 600 mV, plus or minus 1 percent at 25 C |
| Switching frequency | 1.2 MHz in continuous conduction |
| Package | six pin DRL SOT-563, 1.6 mm by 1.6 mm |
| Light load behaviour | Eco-mode with pulse skipping |
| Sibling order code | TPS563257, forced continuous conduction |
| Document | TPS56325x data sheet, revision A, May 2023 |
Electrical parameters that decide the application
| Input supply current, no load, non switching | 100 uA on the Eco-mode version, 370 uA on the forced PWM version |
| Shutdown current, EN low | 2 uA |
| Input UVLO, rising | 2.80 V to 3.00 V, 2.92 V typical |
| Input UVLO, falling | 2.60 V to 2.80 V, 2.72 V typical |
| High side switch resistance at 5 V or more | 55.0 milliohm, 67.5 milliohm at 3 V |
| Low side switch resistance at 5 V or more | 24.3 milliohm, 30.2 milliohm at 3 V |
| Minimum on time | 60 ns |
| Minimum off time | 110 ns |
| Maximum large duty operation | 95 percent |
| Valley overcurrent threshold | 3.1 A to 5.0 A, 4.1 A typical |
| Negative overcurrent threshold | 1.5 A to 2.5 A, 2.1 A typical |
| Internal soft start | 1.6 ms |
| Overvoltage trip | 115 percent typical, 24 us deglitch |
| Undervoltage trip | 60 percent typical, 220 us deglitch, 14 ms hiccup |
| Power good release, rising | 90 percent typical |
| Power good drop, falling | 85 percent typical |
| Thermal resistance, junction to ambient | 137.4 C per W JEDEC, 74 C per W on the EVM |
| Thermal shutdown | 155 C |
Points to check before this part goes on a BOM
The difference between this part and its sibling is visible only below a light load threshold, and that is where most battery products live. In Eco-mode the converter stops switching when the output is above target and delivers a burst when it falls, so the supply current drops from 370 uA to 100 uA and the switching loss disappears for most of the time. The output ripple, however, becomes a burst at a low repetition rate rather than a 1.2 MHz triangle, and that burst is what a downstream circuit has to tolerate.
One hundred microamps against 370 is 2.4 mAh a day against 8.9 mAh a day. On a 2000 mAh battery the difference is about four years of standby against about seven months, which is the kind of margin that decides whether a product can be sold as a ten year battery life instrument. The comparison holds only while the load is light enough for Eco-mode to stay engaged: the moment the load rises past the threshold the converter returns to continuous conduction and the two parts consume the same.
Pulse skipping moves energy into the audio band. A converter delivering a burst every few hundred microseconds produces a ripple component at that rate, and if the load includes an audio amplifier or a high gain analogue stage with poor rejection at a few kilohertz the result is an audible tone or a low frequency beat. That is the reason the forced continuous sibling exists, and the choice between them is a question about the load rather than about efficiency.
The electrical limits are shared with the forced continuous version, so the engineering work does not change: the 60 ns minimum on time caps the reachable output from a high input, the 110 ns minimum off time caps the fixed frequency duty at about 87 percent, and the 95 percent large duty figure is reached by letting the frequency fall during a supply dip. A 12 V to 5 V rail at 3 A is comfortable on both parts; a 17 V to 0.6 V rail is outside both at 1.2 MHz, in Eco-mode and in continuous conduction alike.
Thermal behaviour in Eco-mode is better than the numbers suggest, because the losses fall with the load and the burst operation means the average dissipation is far below the continuous figure. The 137.4 C per W JEDEC figure describes a 3 A continuous load, which is the state in which Eco-mode is not engaged. A product that runs at 3 A continuously should be evaluated as if it were the forced continuous part, because that is what it is doing.
The valley current limit and the negative current limit work the same way in both versions, but the negative limit behaves differently in Eco-mode. When the load is removed the converter stops switching rather than sinking current, so the negative threshold is only reached in a back driven condition, such as a motor coasting on the same rail or a second supply holding the output up. In that case the converter will still protect itself, and the ripple from the burst mode makes the measurement of the trip point less repeatable than in continuous conduction.
The enable pin threshold of 1.19 V with 190 mV of hysteresis and a 2 Mohm pull-down is what allows a precise under voltage turn on from the input divider. On a 12 V bus, a divider that reaches 1.19 V at 9.5 V keeps the converter off below that point, which is the behaviour a battery product needs to avoid draining a pack flat. The quiescent current of the divider itself is then added to the 100 uA standby figure, and a 100 kohm divider across 12 V draws 120 uA, which is more than the converter.
Where this order code fits
This order code belongs on battery powered and always-on equipment: field instruments, wireless sensor nodes, energy meters, standby rails in appliances and any 12 V or 24 V product that spends most of its life at a few milliamps. It is chosen when the standby current is a specification term rather than an afterthought, and when the rails it feeds can tolerate a ripple that appears in bursts rather than at a fixed frequency. Teams comparing it with a neighbouring part start from our How to Reduce Component Cost page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
When does Eco-mode engage? Below a load threshold that the data sheet defines for the part, the converter stops switching when the output reaches its target and restarts when the output has fallen by the hysteresis band. The threshold is a current, so a rail that idles at a few milliamps spends its time in Eco-mode and a rail that idles at an amp never enters it. The transition itself is automatic, which is why the light load current in a specification is a mode dependent figure.
Will the pulse skipping be audible? It can be. The burst repetition rate depends on the load and the output capacitance and can fall into the low kilohertz range, where an audio amplifier with modest supply rejection will pass it on. A product with an audio path should either use the forced continuous version or place a filter between the converter and the amplifier. A digital only load does not care.
Is the 3 A rating still valid in Eco-mode? At 3 A the converter is in continuous conduction and Eco-mode is not engaged, so the rating applies exactly as it does on the forced continuous part, and so does the thermal figure. The Eco-mode benefit is confined to the light load end of the range and it does not improve the full load capability at all.
How does the standby current compare with a linear regulator? A linear regulator from 12 V to 3.3 V at 1 mA draws 1 mA plus its own quiescent current and dissipates 8.7 mW, while this converter delivers the same milliamp for about 100 uA of input current in Eco-mode. The comparison reverses at very light loads if the regulator has a lower quiescent current, which is why the 100 uA figure has to be compared against the whole standby budget and not just against another switcher.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Power Management Cross Reference page sets out the checks that keep a substitute from failing on the bench.