Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS563206DRLR: 4.2 V to 17 V input 3 A synchronous buck in a six pin SOT563, forced continuous conduction
TPS563206DRLR is a fixed 600 kHz D-CAP3 buck with both FETs inside, a fixed 1.4 ms soft start and forced continuous conduction, so the ripple and the frequency stay the same at every load in a SOT-563 (DRL) body of 6 pins. It runs from 4.2 V to 17 V, holds the output between 0.6 V and 7 V and passes 3 A through FETs of 100 milliohm and 55 milliohm. The 600 mV reference is accurate to plus or minus 1.5 percent at 25 degrees and plus or minus 2 percent over the full temperature range, and the valley current limit sits at 3.9 A typical.
Order code and package
| Order code read out | TPS563206 DRL R: converter TPS563206, DRL six pin SOT563, R large tape and reel |
| Package | SOT-563 (DRL), 6 pins, 1.6 mm by 1.6 mm, part marking T206 |
| Carrier in the vendor addendum | TPS563206DRLR at 4000 pieces on a large reel, and no small reel row for this device; the TPS563203DRLR shares the same carrier |
| Moisture level | Level 1, 260 degrees peak reflow, unlimited floor life |
| Lead finish | Tin, quoted as SN |
| Temperature range | Junction minus 40 to plus 125 degrees, storage minus 55 to plus 150 |
| Absolute maximum | 18 V on VIN, 6 V on FB and EN, 150 degrees junction, and the switch node and bootstrap pin rated for the transient swing of the switching waveform |
Electrical parameters that decide the application
| Input range | 4.2 V to 17 V, with the undervoltage lockout releasing at 3.8 V and dropping out at 3.4 V, so there is 400 mV of hysteresis |
| Output range | 0.6 V to 7 V set by a divider against the 600 mV reference |
| Output current | 3 A continuous with a valley current limit of 3.9 A typical and 3.0 to 4.8 A across units |
| Reference accuracy | 600 mV nominal, 591 to 609 mV at 25 degrees and 588 to 612 mV over the full range, which is plus or minus 2 percent |
| Switching frequency | 600 kHz fixed, with a 55 ns minimum on-time and a 100 ns minimum off-time, which is what allows a 7 V output from a 17 V input at 95 percent duty |
| High side FET | 100 milliohm at 25 degrees, so 3 A costs about 0.9 W of conduction at full duty and less as the duty falls |
| Low side FET | 55 milliohm at 25 degrees, which carries the current for the rest of each period |
| Negative current limit | Minus 1.3 A typical, minus 0.7 to minus 1.9 A across units, the floor in forced continuous conduction when the load is removed |
| Light load behaviour | Forced continuous conduction at every load, holding 600 kHz and the same ripple down to zero current, at the cost of 350 microamp quiescent current against 110 microamp in the Eco-mode version |
| Enable | Active high, 1.21 V to switch on and 1.00 V to switch off, with 200 mV of hysteresis and a 1 microamp pulldown |
| Soft start | Fixed 1.4 ms internal ramp, so the inrush into the output capacitor is set by the capacitance rather than by an external component |
| Protection | Cycle by cycle overcurrent limit, undervoltage lockout, thermal shutdown, and hiccup mode on an output undervoltage fault |
| Thermal | 147.4 degrees per watt junction to ambient on a JEDEC board and 73 degrees per watt on the vendor evaluation board with 2 oz copper |
The two members of the family and the pins that matter
| TPS563206DRLR | the part on this page, forced continuous conduction at light load, 350 microamp quiescent current, marking T206 |
| TPS563203DRLR | the same die with Eco-mode instead of forced continuous conduction, 110 microamp quiescent current, marking T203, same reel qty |
| Pin count | Six pins carry VIN, SW, GND, BST, EN and FB, so the entire converter including the bootstrap capacitor fits in a 1.6 mm square |
| Minimum on and off times | 55 ns and 100 ns set the usable duty range and therefore the ratio between input and output that the fixed 600 kHz can hold |
| Protection style | Overcurrent acts cycle by cycle and clears itself, while an output undervoltage fault goes to hiccup, which is the behaviour that matters when a load shorts |
Points to check before this part goes on a BOM
The choice between this part and the TPS563203 is a choice about light load, not about full load. Both deliver 3 A at 600 kHz from the same 4.2 V to 17 V input and both use the same six pin footprint. The 206 keeps switching at zero load, which holds the ripple and the loop behaviour constant and draws 350 microamp; the 203 stops switching and skips cycles, which drops the standing current to 110 microamp but lets the output ripple grow at light load. A rail that feeds a radio, an ADC or a comparator chain usually wants the 206, and a standby rail that sits idle for days usually wants the 203.
A 600 kHz fixed frequency with a 55 ns minimum on-time is what makes a 7 V output from a 12 V or 17 V input possible, and the same minimum on-time is what limits how far down the output can go from a high input. At 17 V in and 0.6 V out the on-time is close to the floor, so a board that needs a very low output from a high input should check the duty against the minimum on-time before the inductor is chosen rather than after.
The valley current limit of 3.9 A typical sits only 30 percent above the 3 A rating, which is normal for a converter expected to survive a short rather than ride through a sustained overload. Valley sensing means the peak current is the limit plus half the inductor ripple, so a small inductor with a large ripple trips the limit earlier than the number suggests and a larger inductor allows slightly more real current before the limit acts.
The thermal figure is the one to quote for a 3 A load in a 1.6 mm square. The JEDEC number is 147.4 degrees per watt, and the vendor evaluation board with 2 oz copper brings it to 73 degrees per watt. At 3 A and a 1.8 V output from 12 V the conduction loss in the two FETs is a little under 0.5 W, so the copper under the part is what decides whether the junction stays inside its range at a 70 degree ambient.
The fixed 1.4 ms soft start has a practical consequence for a board with a large output capacitance. The ramp current into the output capacitor is the capacitance times the voltage divided by 1.4 ms, and it adds to the load current for the length of the ramp. A rail with 470 microfarad of output capacitance at 3.3 V pulls about 1.1 A of charging current during start, which is inside the 3.9 A limit but worth knowing when the load also starts at the same moment.
Hiccup on an undervoltage fault is the behaviour that separates this part from a latched controller. If the output is pulled below its window the part stops, waits, and tries again, so a shorted load produces a low duty retry pattern rather than a dead rail. That is usually what a customer wants on a board that has to recover without an operator, and it is the reason the fault behaviour is worth stating on the quote rather than leaving to the data sheet.
Where this order code fits
Fits televisions, set top boxes, building automation controllers, broadband fixed line access equipment and any 12 V or 5 V board that needs a 3 A rail from a small footprint with a constant switching frequency. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
What is the difference between the TPS563206 and the TPS563203? Light load behaviour only. The 206 runs forced continuous conduction and holds 600 kHz at every load with a 350 microamp quiescent current, while the 203 uses Eco-mode and drops to 110 microamp with a larger ripple at light load. The footprint and the reel are identical.
Is an external compensation network needed? No. D-CAP3 closes the loop inside the package and the data sheet gives the output capacitor window that keeps it stable, including low ESR polymer and ceramic parts.
What current limit should a 3 A load expect? A valley limit of 3.9 A typical with a 3.0 to 4.8 A spread, and because the sense is on the valley the peak inductor current sits above that by half the ripple.
How much copper does the part need? The JEDEC figure is 147.4 degrees per watt and the vendor board with 2 oz copper gives 73 degrees per watt, so the copper area under the six pins is what sets the usable current at a high ambient.
Does the output discharge when the part is disabled? The TPS56320x family does not include an output discharge circuit, so a rail that has to fall quickly after disable needs an external path or a different part.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the One Stop BOM Sourcing page sets out the checks that keep a substitute from failing on the bench.