TPS54339DDAR
Product Specifications
TPS54339DDAR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS54339DDAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS54339DDAR: 23 V input, 3 A synchronous step-down converter in a D-CAP2 control loop with no external compensation
TPS54339DDAR is a fixed frequency synchronous buck converter that regulates without an external compensation network and works with either ceramic or polymer output capacitors in a SO PowerPAD (DDA) body of 8 pins. It takes 4.5 V to 23 V in, delivers 3 A at any output from 0.76 V to 7 V, switches at a fixed 600 kHz, and uses 140 mOhm and 70 mOhm integrated switches. The reference sits at 765 mV, the current limit window runs from 3.5 A to 5.7 A, and the part needs no compensation components around the error amplifier.
Order code and package
| Ordering string | TPS54339DDAR, the eight pin SO PowerPAD body on a 2500 piece large reel |
| Part marking | 54339 on the body |
| Body | Eight pin SO PowerPAD, the DDA outline, with the exposed pad on the underside as the heat path |
| Material | RoHS compliant, nickel palladium gold finish, moisture level 2 with a one year floor life at 260 degrees |
| Tube option | The same body is offered in a 75 piece tube under the DDA suffix without the R, which is the row to use for a prototype build |
| Temperature | minus 40 to 85 degrees ambient, which is the range the electrical table is specified over |
| Control topology | Adaptive on time D-CAP2, a fixed frequency loop that needs no external compensation and accepts ceramic or polymer output capacitors |
Electrical parameters that decide the application
| Input range | 4.5 V to 23 V, with an undervoltage lockout that wakes at 3.75 V typical on the internal 5 V rail rather than on the input directly |
| Output range | 0.76 V to 7 V, set by a divider into the 765 mV reference, with 749 to 781 mV specified across the full temperature range |
| Output current | 3 A continuous, with the cycle by cycle current limit window at 3.5 to 5.7 A and 4.1 A typical |
| Switching frequency | 600 kHz fixed, with a 160 ns on time at 12 V in and 1.05 V out and a 260 to 310 ns minimum off time |
| Switch resistance | 140 mOhm high side and 70 mOhm low side, which is what caps the 3 A rating at high duty rather than the silicon current limit |
| Quiescent current | 850 uA typical and 1.2 mA maximum while not switching, 3 uA typical and 10 uA maximum in shutdown |
| Internal rail | A 5.5 V regulator for the gate drive, specified from 5.2 V to 5.7 V, which sets the gate overdrive for both switches |
| Soft start | A 6 uA current source into an external capacitor, with a 1.5 mA discharge path when the part is disabled, so the ramp restarts from zero on every enable |
| Protection thresholds | Output overvoltage at 125 per cent of nominal, undervoltage hiccup at 65 per cent with a 6 us delay multiplied by the soft start time |
| Enable | 1.6 V minimum for a high, 0.6 V maximum for a low, with a 400 kOhm internal resistance to ground on the pin |
| Thermal shutdown | 165 degrees junction with 40 degrees of hysteresis, which is above the 85 degree ambient rating and therefore a protection rather than an operating point |
| Thermal path | The PowerPAD is the only path to the board, and at 12 V to 1.8 V and 3 A the converter dissipates about 0.9 W |
Family variants and how they differ
| D-CAP2 against a voltage mode loop | The loop compares the output ripple against a threshold and sets the on time from the input and output ratio, so it responds within a cycle and needs no compensation network. The price is that the loop depends on the output capacitor's equivalent series resistance and on the ripple at the feedback pin |
| Ceramic and polymer output capacitors | The control circuit adapts to both, which is unusual. A polymer capacitor with 10 mOhm of series resistance and a ceramic bank with almost none both hold the loop stable, and the output ripple is what changes between them |
| Hiccup undervoltage | The 65 per cent threshold with a delay scaled by the soft start time means a short on the output is retried rather than held at the current limit. That keeps the average dissipation low while the fault is present |
| Overvoltage response | At 125 per cent of nominal the part stops switching and lets the load discharge the output, which protects a processor on a rail that is pulled up by an external source |
| Pre-biased start | The soft start allows the part to start into an output that is already charged, without pulling the rail down first. That matters when a second supply holds the rail during a restart |
| What the 3 A rating depends on | On the 140 mOhm high side switch and the thermal path, not on the current limit. At 23 V in and 0.76 V out the duty is short but the high side conduction and switching losses still decide whether 3 A can be delivered continuously |
Points to check before this part goes on a BOM
The 3 A rating is a thermal rating as much as an electrical one. With 140 mOhm and 70 mOhm switches and a 12 V input, the part reaches its dissipation limit before the 5.7 A top of the current limit window, so the board copper matters more than the headline number.
The current limit is a window from 3.5 A to 5.7 A. An inductor chosen for a 3 A load has to saturate above 5.7 A, or the part will lose control of the current during a transient that would otherwise be inside the specification.
The reference is 765 mV with a 749 to 781 mV window over temperature. A 1.8 V rail built with a one per cent divider is therefore closer to a three per cent rail, and the divider tolerance is usually the larger of the two errors.
The D-CAP2 loop depends on the ripple at the feedback pin. A board that adds a large capacitor directly at the feedback node, or routes it past a noisy trace, changes the loop behaviour even though nothing in the power stage has changed.
This part is rated to 85 degrees ambient and not to 125. A board that specifies industrial temperature range for the surrounding components has to look at this rating separately, and the thermal shutdown at 165 degrees will not protect a load that is already out of specification at 100.
The internal 5.5 V rail sets the gate drive. A heavy load on that pin, or a bootstrap capacitor that is too small, shows up as a loss of gate drive and a hot high side switch rather than as a clean current limit event.
Why a converter without a compensation network is not automatically simpler
Removing the compensation network removes two or three parts and the task of stabilising a loop, which is a real saving on a cost sensitive board. It does not remove the dependence on the output capacitor, because a loop that senses ripple at the feedback pin is reacting to that ripple, and the capacitor sets both its amplitude and its phase.
The practical result is that the output capacitor becomes the part that has to be checked when the load changes or the board is respun with a different vendor's ceramic. That is a different kind of work from tuning a compensation network, not less work, which is why the capacitor specification in the data sheet is longer than the compensation section it replaces.
Where this order code fits
12 V and 19 V bus conversion inside set top boxes, digital televisions, monitors, network attached storage and industrial controllers, plus any board that has to make 5 V, 3.3 V or 1.8 V from a bus that can reach 23 V. The D-CAP2 loop is what makes it usable with a small ceramic output capacitor without a compensation network, which is the reason it appears on cost sensitive boards with a short bill of materials. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the How to Reduce Component Cost page.
Questions buyers ask
Does it need external compensation? No. The D-CAP2 loop is internally set and the part is stable with ceramic or polymer output capacitors without a compensation network around the error amplifier.
What is the output current limit? A window from 3.5 A to 5.7 A, with 4.1 A typical. An inductor for a 3 A load has to saturate above the top of that window.
Can it start into a pre-charged output? Yes, the soft start ramps from the existing output voltage rather than pulling the rail down first, which is what allows a restart while another source holds the rail.
What happens on a shorted output? The part enters hiccup at 65 per cent of nominal, waits for a delay scaled by the soft start time, and retries, so the average dissipation stays low while the fault is present.
What is the maximum ambient temperature? 85 degrees. The thermal shutdown sits at 165 degrees junction, which is above the rating and is a protection rather than an operating point.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the One Stop BOM Sourcing page sets out the checks that keep a substitute from failing on the bench.