Contact Us

TPS54335ADDAR 25+

Brand: Texas Instruments
Texas Instruments TPS54335ADDAR 25+ is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS54335ADDAR 25+ — Power Management & Signal Chain | Superb Automation

TPS54335ADDAR 25+

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS54335ADDAR 25+ from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS54335ADDAR: a 3 A, 28 V buck in an eight pin SO PowerPAD

TPS54335ADDAR is the eight pin SO PowerPAD member of the TPS5433xA family, a synchronous step-down converter that takes 4.5 V to 28 V in and delivers 3 A out with the high-side and low-side FETs inside the package. It is the variant with the internal 2 ms soft start and the adjustable switching frequency, which separates it from the TPS54336A that fixes the frequency at 340 kHz and brings the soft start out to a pin.

The eight pin body is the reason this part still appears on cost sensitive boards. A 3 A converter normally needs a controller, two FETs, a bootstrap diode and a handful of passives, and this device replaces all of that with one part and an inductor. The SO PowerPAD package is a leaded body with an exposed pad, so it can be assembled on a line that does not run fine pitch leadless parts and it can be reworked with ordinary tools.

The numbers below come from SLVSCD5D, revised February 2016, and from the orderable addendum in the same document.

What the order code sits on

Functionsynchronous step-down converter with integrated FETs
Input range4.5 V to 28 V
Output current3 A continuous
High-side FET128 milliohm
Low-side FET84 milliohm
Reference0.8 V with 0.8 percent accuracy, 1.5 percent over temperature
Switching frequency50 kHz to 1.5 MHz, adjustable with a resistor
Soft startinternal 2 ms on this variant
Controlcurrent mode with external compensation
Light loadpulse skipping
Overcurrentcycle by cycle high side limit plus low side sourcing limit, hiccup after the timeout
Protectionthermal shutdown with hiccup restart, overvoltage transition
Shutdown current2 microamps
PackageSO PowerPAD DDA, 8 pins, 4.89 mm by 3.90 mm
Reel in this page2500 pieces on a large reel, moisture level 2

The two current limits and what they protect

The high-side limit is a cycle by cycle comparison against the peak current in the FET, and it is the limit that a shorted output trips first because the current ramps while the high side is on. The low-side sourcing limit is the second line: if the inductor current keeps rising while the low side is on, the device turns the low side off rather than letting the current run away. There is also a low-side sinking limit, which turns the low side off when current flows backwards from the output, and that is what allows the converter to start into a pre-biased output without pulling the rail down.

Hiccup protection is the third layer. If the overcurrent condition persists for longer than the internal timeout, the device stops switching, waits, and restarts. A persistent short therefore produces a burst of switching every timeout period rather than continuous current, which keeps the die and the inductor inside their ratings while the fault is present. The hiccup also means a bench test with a shorted output shows a repeating burst rather than a steady zero, and that is normal.

The limits are not a substitute for a fuse. A 3 A converter that hiccups into a short still delivers a pulse of current every cycle, and the source impedance and the inductor saturation current set how large that pulse is. A board that must be safe under a shorted load needs the upstream protection as well.

Compensation, frequency and the inductor

The converter uses current mode control with an external compensation network on the COMP pin, so the loop is closed by the customer rather than fixed inside. That is more work than a internally compensated part, and it is also what allows the same device to run from 50 kHz to 1.5 MHz and to drive a range of inductors and output capacitors. The compensation components scale with the crossover frequency, which is chosen as a fraction of the switching frequency, so a board that changes the frequency also changes the compensation.

The 128 milliohm high side and 84 milliohm low side set the conduction loss, and at 3 A the conduction loss in the low side is about 0.75 W, which is the dominant term at low duty cycle. That is why the part is a 3 A device and not a 5 A device in the same body: the loss at higher current would need a bigger package and a bigger thermal pad, and the SO PowerPAD can only pass so much into the board.

The inductor value follows from the ripple requirement. At 28 V in and 5 V out the duty cycle is short and the ripple is large for a given inductance, so a 28 V application usually runs a lower frequency than a 12 V application with the same output. A 500 kHz setting gives a reasonable compromise between inductor size and switching loss for a 24 V to 5 V rail.

Start-up, pre-bias and the 2 ms ramp

The internal 2 ms soft start ramps the reference, which ramps the output, and it is fixed on this variant. That is long enough to keep the inrush into the output capacitors inside the current limit for a typical 22 to 47 microfarad output, and it is short enough that a system waiting for the rail does not time out. A board with a much larger output capacitance needs either a longer ramp or a current limit that covers the inrush, and this variant cannot extend the ramp.

Starting into a pre-biased output is supported by the low-side sinking limit described above, which prevents the converter from pulling the output down when it begins switching. That matters when a rail is held up by a second supply or by a bus that is already powered, and it is the behaviour that lets the converter be used as a second stage after another regulator.

The overvoltage transition protection reacts when the feedback pin rises above the reference by more than a set margin, and it stops the high side from switching. A rail that is pushed up by an external source therefore does not see the converter fight it, and the output does not overshoot when the load drops.

Carriers and what the addendum prints

TPS54335ADDARSO PowerPAD DDA, 8 pins, 2500 pieces on a large reel, active
TPS54335ADDAsame body, 75 pieces in a tube
Lead finishNIPDAU on the reel rows, NIPDAU or tin on the tube row
Moisture levelLevel-2-260C-1 YEAR
Operating temperatureminus 40 to plus 150 degrees on the addendum row
Part marking54335A
Sibling body10-pin VSON DRC at 3000 pieces on a large reel
Sibling variantTPS54336A, fixed 340 kHz with an adjustable soft start

The tube option is the one to remember for a hand built prototype. Seventy five parts in a tube can be placed by hand or on a short run line without setting up a reel feeder, and the reel row is the one for volume. Both rows are active, and both carry the same die, so a change from tube to reel does not change the circuit.

The temperature row reads minus 40 to plus 150 degrees, which is a junction figure and not an ambient one. A board inside a sealed box will reach that junction long before the air around it reaches 150 degrees, and the thermal pad and the copper under it are what decide how much power can be dissipated before the thermal shutdown engages.

Where this converter still wins

Industrial controls, smart meters, set-top boxes and network equipment all run a 12 V or 24 V bus and need a 3.3 V or 5 V rail at a couple of amps. This part covers that with one inductor and a compensation network, on a line that can place a leaded package, and it survives a 28 V input with margin for a 24 V bus at plus 10 percent.

Its limit is the 3 A rating and the 28 V ceiling. Above 28 V the part is out of range and a 60 V family member takes over; above 3 A the package runs out of thermal headroom. For a customer moving a board from an older 2 A converter, the swap is usually a matter of checking the compensation and the inductor saturation current rather than the pinout, because the eight pin body has been stable across the family. Our power management cross reference page sets out the comparison, and the component lead time solutions page covers what to do when the exact string is quoted beyond the build date.

Questions buyers ask before a first order

Is the compensation fixed? No. The COMP pin is brought out and the network is chosen for the inductor and output capacitor on the board, so a copy of another board's drawing is not a safe starting point.

Can the frequency be changed without other changes? It can, but the compensation has to be recalculated and the inductor ripple changes with it. A board that moves from 500 kHz to 1.5 MHz keeps the same output but needs a different COMP network.

What is the difference from the TPS54336A? The 336A has a fixed 340 kHz frequency and an adjustable soft start, while this variant has an adjustable frequency and a fixed 2 ms soft start. The pinout is the same, and the choice depends on which of the two functions the board needs.

Does it need a bootstrap capacitor? Yes, between the BOOT pin and the switch node, as with any synchronous buck of this arrangement. The value is in the data sheet application section and is not optional.