TPS54061DRBT
Product Specifications
TPS54061DRBT
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS54061DRBT from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS54061 60 V 200 mA synchronous step down with 90 microamp quiescent current
The TPS54061DRBT is a wide input synchronous step down converter rated at 60 V and 200 mA, in the 8 pin DRB body. It is the synchronous member of the family: where the TPS54060 uses a diode or an external synchronous switch, this part has both switches inside, with 1.5 ohm typical and 3 ohm maximum on the high side and 0.8 ohm typical and 1.5 ohm maximum on the low side. The low side switch is what makes the part interesting at light load, because the part can stop the inductor current from going negative, which is how the quiescent current stays at 90 microamp typical while the output is regulated.
The input range is 4.7 V to 60 V, slightly narrower at the bottom than the 3.5 V of the non synchronous part. That 4.7 V floor is the price of the synchronous stage: the high side gate drive needs the boot capacitor charged, and below 4.7 V the part cannot guarantee it. For a 12 V or 24 V rail this is irrelevant, and for a rail that has to start from a 5 V bus it is the first number to check.
Key parameters taken from the SLVSBB7E document
| Input range | 4.7 V to 60 V operating, 62 V absolute maximum on VIN, with VIN start at 4.5 V |
| Output current | 200 mA, with the high side current limit at 250 mA minimum, 350 mA typical and 500 mA maximum |
| Switch resistance | High side 1.5 ohm typical and 3 ohm maximum, low side 0.8 ohm typical and 1.5 ohm maximum at 12 V in |
| Quiescent current | 90 microamp typical and 110 microamp maximum while not switching at 12 V in, 1.4 microamp in shutdown |
| Switching frequency | 50 kHz to 1100 kHz set by the RT/CLK resistor, or 300 kHz to 1100 kHz when synchronised to an external clock |
| Reference | 0.8 V, 0.792 V to 0.808 V at 25 degrees and 0.784 V to 0.816 V over minus 40 to plus 150 degrees |
| Zero cross detect | 1.1 mA of inductor current, which is the threshold where the low side switch turns off in light load operation |
| Enable pin | 1.23 V to 1.4 V rising and 1 V to 1.18 V falling, 4.7 microamp of input current and 3.5 microamp of hysteresis current |
| Thermal | 42.9 degrees per watt junction to ambient in the 8 pin DRB body, 46 degrees per watt junction to case top |
| ESD | 2000 V human body model and 500 V charged device model |
The 200 mA rating and what limits it
The current limit is the first limit, and it is not 200 mA. The high side sourcing limit is 250 mA minimum, which means a part can trip with 250 mA flowing and 200 mA guaranteed. The second limit is thermal: at 60 V in and 5 V out, the duty cycle is about 8 per cent, and the high side switch conducts for that fraction while the low side conducts the rest. With 1.5 ohm of low side resistance at 200 mA the conduction loss is 60 milliwatts, which the DRB body can remove at 42.9 degrees per watt with a modest copper area. At 60 V in the switching loss grows with the square of the input voltage and becomes the dominant term, so a 60 V to 5 V rail at 200 mA is a hotter build than a 12 V to 5 V rail at the same current.
Light load behaviour and the zero cross threshold
In light load the low side switch turns off when the inductor current falls to 1.1 mA, and the part enters a pulse frequency mode where the output is held between two thresholds. The quiescent current in that state is the 90 microamp figure, which is what makes the part suitable for a standby rail that has to keep a real time clock or a wake circuit alive from a 24 V bus for years. The penalty is ripple, which grows as the load falls because the bursts become less frequent, and a small amount of low frequency noise on the output.
Soft start, tracking and the boot capacitor
The SS/TR pin takes a capacitor and charges it with a current that sets the ramp, and the same pin can be driven from another rail to make this supply track a higher voltage. The boot capacitor between BOOT and PH is charged during the off time, and the part monitors it, turning the high side switch off if the boot voltage falls below a threshold. That monitor is why the part can run at high duty cycles without a separate charge pump, and why a missing boot capacitor shows up as a rail that never reaches regulation rather than as a part that fails.
Where the part fits and how to quote it
Typical sockets are a 24 V to 3.3 V housekeeping rail, a 48 V to 12 V bias in a telecom line card, and a sensor supply in an industrial node where the 200 mA ceiling is enough. The synchronous stage and the low quiescent current are the two reasons to pick it over the non synchronous family member, and the 4.7 V input floor is the reason not to.
On the commercial side the part is a small reel item and the body is the 8 pin DRB, so the reel size and the moisture level are worth confirming with each quote, since a 250 piece reel and a 3000 piece reel can both be quoted as the same base part number. Our desk quotes the reel size explicitly and shows the synchronous and non synchronous alternatives side by side when a lead time moves, on power management cross reference and component lead time solutions.
Frequently asked questions
Does the part need an external diode. No, the low side switch replaces it, and adding a diode in parallel is unnecessary and slightly harmful, since it conducts before the switch does at light load and defeats the zero cross detection.
Can the output be above the input. No, this is a step down converter with no boost mode, and the output follows the input down once the input falls below the regulation point. For a rail that has to hold up during a dip, the answer is more input capacitance rather than a different mode.
What is the minimum output voltage. The reference is 0.8 V, so the output can be set down to that level, and the practical floor is set by the minimum on time at the chosen frequency. More on the sourcing side is on one stop BOM sourcing.