Contact Us

TPS54040ADGQR

Brand: Texas Instruments
Texas Instruments TPS54040ADGQR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS54040ADGQR — Power Management & Signal Chain | Superb Automation

TPS54040ADGQR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS54040ADGQR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS54040ADGQR: 0.5 A, 42 V Step-Down Converter With 200 mOhm Switch and 116 uA Quiescent

TPS54040ADGQR is a current-mode step-down converter with the high-side switch inside in a 10-pin VSON body of 10 pins. It runs from 3.5 V to 42 V, delivers 0.5 A, switches anywhere between 100 kHz and 2.5 MHz, and draws 116 uA at no load with 1.3 uA in shutdown.

Order code and package

Ordering stringTPS54040ADGQR, VSON-10 (DGQ), 3 mm by 3 mm, PowerPAD, tape and reel
Second packageTPS54040ADGK, MSOP-PowerPAD-10 (DGK), 3 mm by 3 mm
Input3.5 V to 42 V operating, 47 V absolute maximum on VIN and PH
Output0.8 V to VIN adjustable against a 0.8 V reference, set by the feedback divider
Current0.5 A, with a 0.6 A to 0.94 A peak switch current limit at 12 V and 25 C
Switching frequency100 kHz to 2.5 MHz with a resistor on RT/CLK, 300 kHz to 2.2 MHz on an external clock
Junction temperature-40 C to +150 C, thermal shutdown at 182 C
Power goodopen drain, asserts when the output is inside 94 percent to 107 percent of nominal

Electrical parameters that decide the application

Reference0.8 V, 0.792 V to 0.808 V at 25 C, 0.784 V to 0.816 V over the full range
High-side resistance200 mOhm typical at 12 V in with 6 V on the boot capacitor, 410 mOhm maximum
Low input resistance300 mOhm typical at 3.5 V in with 3 V of boot drive, the worst corner
No load current116 uA typical, 136 uA maximum at 12 V in with the loop in regulation
Shutdown current1.3 uA nominal with the enable pin low
Enable threshold1.11 V to 1.36 V, 1.25 V typical, with a 2.95 uA hysteresis current
Internal UVLO2.5 V on VIN, raised by a divider on the enable pin when the rail is slow
Error amplifier97 uS transconductance, 2.7 MHz bandwidth, 1.9 A per V to the switch current
Thermal shutdown182 C junction, no hysteresis in the published table

Points to check before this part goes on a BOM

The load rating and the current limit are not the same number. At 12 V and 25 C the limit is 0.6 A minimum and 0.94 A maximum, so a 0.5 A load with 30 percent of ripple reaches 0.575 A of peak current and sits just inside the minimum limit; at 42 V in the same inductor carries more ripple for the same load, and the peak crosses 0.6 A first, which is why the inductor is chosen for the highest input rather than the nominal one.

The reference is 0.8 V plus or minus 1 percent at 25 C and plus or minus 2 percent over the full range, which is 16 mV. A 5 V output divides that by 5.25, so 2 percent becomes 100 mV at the output, and the divider pair adds its own tolerance on top. A 3.3 V output has a 4.125 ratio and the same relative error, so the reference is the dominant DC term in both cases.

116 uA at no load is 1.02 Ah over a year and 1.3 uA in shutdown is 11.4 mAh, a factor of 89. On a 24 V industrial loop the no load current is 2.8 mW of standing loss, which matters for a sensor node on a solar cell and does not matter for a 200 W cabinet supply, so the two ends of the range are used differently.

At 2.5 MHz and 42 V in a 3.3 V output is 31.4 ns of on-time. The switch node edges of a 42 V converter are tens of nanoseconds wide, so a pulse that short spends a large share of its life in the transition and the efficiency and the voltage accuracy both suffer. The same ratio at 500 kHz is 157 ns and at 300 kHz it is 262 ns, which is where a 42 V rail belongs.

The high-side resistance is 200 mOhm at 12 V but 300 mOhm at 3.5 V, because the boot capacitor is charged to 3 V at that input and the gate drive is weaker. At 0.5 A the conduction loss goes from 50 mW to 75 mW, and the same corner is where a bootstrap diode drop eats into the available gate voltage, so a 3.5 V to 5 V rail is the harder case than a 12 V to 5 V rail.

The power good window of 94 percent to 107 percent is wider than the reference tolerance, so it cannot be used as a precision monitor; it tells a supervisor that the rail is roughly there. On a 5 V output the window is 4.70 V to 5.35 V, and the 6 percent low side is the one that trips first on a load step, because the flag follows the output rather than the setpoint.

Where this order code fits

It is used in 12 V and 24 V industrial control supplies, aftermarket automotive accessories, metering and building electronics, and any board that has to survive a 42 V transient on the input while producing a 5 V or 3.3 V housekeeping rail at a few hundred milliamps. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the How to Reduce Component Cost page.

Questions buyers ask

Will it survive a 42 V automotive load dump? No. The operating input is 42 V and the absolute maximum is 47 V, while a load dump reaches 60 V, so a clamp or a higher voltage part is needed.

How is the frequency set? A resistor from RT/CLK to ground for 100 kHz to 2.5 MHz, or an external clock between 300 kHz and 2.2 MHz with a pulse at least 40 ns wide.

Is 0.5 A available from 42 V to 3.3 V? Yes, at 1.65 W of output and roughly 0.35 W of loss, which the 3 mm by 3 mm PowerPAD package carries on a copper plane.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.