TPS51219RTER
Product Specifications
TPS51219RTER
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS51219RTER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS51219RTER: Single Synchronous Buck Controller With Differential Feedback, 28 V In, 20 A Out
TPS51219RTER is a single-phase adaptive on-time buck controller in a 16-pin QFN body of 16 pins. It holds the output between 0.5 V and 2 V at 20 A and above from a 3 V to 28 V conversion input, selects D-CAP or D-CAP2 behaviour at the MODE pin, and needs a separate 5 V bias supply for the gate drive.
Order code and package
| Ordering string | TPS51219RTER, QFN-16 (RTE), 3 mm by 3 mm, tape and reel |
| Conversion input | 3 V to 28 V at the high-side drain, 28 V is the switch node supply not the bias |
| Bias supply | 5 V at V5IN, external, required for the drivers and the internal housekeeping |
| Output | 0.5 V to 2.0 V adjustable, fixed 1.05 V and 1.00 V options set at the REFIN pin |
| Load | 0 A to 20 A and above, external FETs and inductor set the real ceiling |
| Control | D-CAP at 300 kHz or 400 kHz, D-CAP2 at 500 kHz or 670 kHz, chosen at MODE |
| Temperature | -40 C to +85 C ambient, 16-pin 3 mm by 3 mm body |
Electrical parameters that decide the application
| Reference | 2 V at VREF, plus or minus 1 percent over temperature, 1 mA current limit |
| Current sensing | low-side RDS(on) sensing with 4700 ppm per C compensation, or an RSENSE option |
| 4700 ppm per C | 0.47 percent per degree C, 47 percent over a 100 C junction swing |
| Soft start | internal 1 ms voltage servo ramp, no external capacitor |
| Protections | OVP, UVP, OCP, non-latched thermal shutdown, output discharge on disable |
| Status | power good output, open drain, plus a dedicated enable pin |
| Gate drive | adaptive on-time with an integrated boost switch for the high-side driver |
| Package | 3 mm by 3 mm QFN with the pins carrying the heat, no large thermal pad |
Points to check before this part goes on a BOM
The 4700 ppm per C term is the whole argument for the RSENSE option: 0.47 percent per degree C over a 100 C junction swing moves the low-side resistance by 47 percent, so a limit set at 20 A on a cold board trips near 13.6 A on a hot one if the sensing is left uncompensated. The compensation network pulls most of that back, and a 1 percent sense resistor removes the question at the cost of 20 A through 1 milliohm, which is 0.4 W.
The reference is 2 V and the output floor is 0.5 V, so the REFIN divider runs at a 4:1 ratio at the bottom of the range and 2:1 at 1 V. The divider sits between VREF and the output, so its two resistor tolerances add directly to the 1 percent reference: two 0.1 percent parts give 0.2 percent, and two 1 percent parts give 2 percent, which is twice the reference error.
The 5 V bias is not optional and it is not derived internally: the drivers run from V5IN while the power stage runs from the 3 V to 28 V input, so a board with only a 12 V rail needs a small 5 V housekeeping supply or a charge pump, and a board with only 3.3 V cannot start the controller at all until that rail exists.
At 20 A and 1.05 V the output is 21 W, and at 90 percent the loss is 2.3 W in two external FETs and an inductor, none of it in the 3 mm by 3 mm controller body. That split is why the part can carry 20 A in a tiny package: the heat is somewhere else, and the somewhere else has to be sized before the rail is called a 20 A rail.
D-CAP and D-CAP2 are not two names for one loop. D-CAP2 is the mode that works with all-ceramic output capacitors, while D-CAP depends on the ripple the capacitor stack presents, so a ceramic-only board left in D-CAP at 300 kHz has too little ripple for the comparator and shows jitter or a split pulse. The MODE resistor is therefore a bill of materials decision.
Adaptive on-time follows the ratio of output to input, so the 300 kHz to 670 kHz figures hold in continuous conduction only. Below the critical current the controller skips pulses and the frequency falls away, which is acceptable for a notebook rail in standby but not for a rail that has to keep a fixed switching frequency for an EMI plan.
Where this order code fits
The part was written for notebook VCCIO and point-of-load rails where the output is 1.05 V or 1.2 V at 15 A to 20 A and the input is a 12 V to 20 V adapter or battery rail, and it is used the same way in set-top boxes, network appliances and instrument backplanes that need a low voltage rail with tight DC accuracy. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Can it run from a 3.3 V input alone? No. The conversion input may go down to 3 V, but the 5 V bias at V5IN has to be present before the drivers work.
Does it need a sense resistor? No. Low-side RDS(on) sensing is the default and the RSENSE option exists for boards that need the current limit to ignore junction temperature.
Is 20 A the controller limit? The controller drives 20 A and above; the FETs, the inductor and the copper set what the rail can actually deliver.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Reduce Component Cost page sets out the checks that keep a substitute from failing on the bench.