TPS4H160AQPWPRQ1
Product Specifications
TPS4H160AQPWPRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS4H160AQPWPRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS4H160AQPWPRQ1: 40 V, 160 mOhm quad automotive high side switch, version A, in a 28 pin HTSSOP
TPS4H160AQPWPRQ1 is four protected high side switches in one package, built to drive lamps, relays and modules from a 12 V automotive rail with diagnostics on every channel in a HTSSOP body of 28 pins. It switches four independent loads from 3.4 V to 40 V with 160 mOhm of on resistance per channel, draws under 500 nA in standby, and limits current either internally or through one external resistor with 15 per cent accuracy above 500 mA. Version A brings an open drain digital fault output per channel; version B replaces that with an analogue current sense.
Order code and package
| TPS4H160AQPWPRQ1 | 28 pin HTSSOP (PWP), thermally enhanced, 2000 pieces on a large reel, marking 4H160AQ, moisture level 3 with a 168 hour floor life |
| TPS4H160BQPWPRQ1 | version B, same body and pin count, analogue current sense output in place of the digital fault flags, marking 4H160BQ |
| Channel count | four, each with its own input pin and its own protection |
| On resistance | 160 mOhm per channel at 25 C, which is the figure in the part number |
| Temperature grade | AEC-Q100 grade 1, minus 40 C to plus 125 C ambient, HBM class H3A and CDM class C4B |
Electrical parameters that decide the application
| Operating voltage | 3.4 V to 40 V, covering a 12 V rail with load dump clamps and a 24 V truck rail |
| On resistance | 160 mOhm per channel, so 1 A through one channel dissipates 160 mW |
| Standby current | under 500 nA with all channels off, which is the figure that keeps a parked vehicle from draining its battery |
| Current limit | internal threshold or set by one external resistor, with 15 per cent accuracy above 500 mA of load |
| Current sense accuracy | 15 per cent above 25 mA on version B, and 8 per cent on the higher current rows |
| Diagnostics | overcurrent and short to ground, open load and short to battery, with a global fault report for a fast interrupt |
| Protection | thermal shutdown with a latch off option, thermal swing, inductive load negative clamp and loss of ground or battery |
| Slew rate | optimised turn on and turn off to keep conducted emissions inside the automotive limits |
| Interface | one input pin per channel plus a diagnostics enable pin, with an internal pull down on the enable |
| Body | 28 pin HTSSOP with an exposed pad, which is the thermal path for four channels at once |
Version A against version B
| Version A | open drain digital output per channel, which reports a fault but not its size; this is the page order code |
| Version B | analogue current sense on the same pins, which reports the load current as a voltage and needs an external resistor to convert it |
| Why it matters | a lamp or a relay only needs to know that the channel failed, while a motor or a heater needs to know how much current it is drawing |
| DIAG_EN pin | enables the diagnostic path, and tying it to ground disables the external current limit setting on the same pin |
| Latch off option | thermal shutdown can be configured to latch, which keeps a faulted channel off until the controller resets it |
| Thermal swing | a second, lower thermal threshold that reports a channel that is close to its limit rather than one that has already tripped |
Points to check before this part goes on a BOM
The part number says 160 mOhm and that is the on resistance of one channel at 25 C. At 125 C the figure roughly doubles, so a load drawing 1 A through one channel dissipates 160 mW cold and closer to 300 mW hot. With four channels at 1 A each the package is handling more than a watt, and the exposed pad and the copper under it are what decide whether the product survives a hot soak in a dashboard.
The standby current of under 500 nA is a hard requirement in automotive rather than a nice figure. A body control module that stays connected to the battery for months has a budget of a few hundred microamps in total, and four channels that leak a microamp each would consume the whole allowance before the microcontroller wakes up. That is why the part is specified at nanoamps rather than microamps.
Version A and version B are the same silicon with a different output stage on the diagnostic pins, and choosing the wrong one is a board change rather than a part change. An open drain fault flag tells the controller that a channel tripped, which is enough for a lamp or a relay. A motor or a heater that has to distinguish a stall from an inrush needs the analogue current, which is version B.
The current limit can be internal or set by one external resistor, and the accuracy of the external setting is 15 per cent above 500 mA but only for overloads greater than 1.5 times the set point. Below that multiplier the limit is a soft foldback rather than a hard clamp, so a load that sits just above the setting may never trip the flag. The vendor note is explicit about the condition and it is the first thing to check when a channel reports nothing.
The diagnostic enable pin doubles as the current limit setting pin, and grounding it disables the external limit. That is convenient for a board that uses the internal limit and a trap for one that grounds the pin to save a resistor and then wonders why the external limit does nothing. The pin also has an internal pull down, so leaving it floating selects the default behaviour rather than the intended one.
Thermal shutdown with the latch off option is the difference between a channel that retries into a short and one that stays off until the controller clears it. A retrying channel in a wiring harness fault will heat and cool repeatedly, which is hard on the package and invisible to a driver. A latched channel reports the fault once and stays off, and the controller can decide when to try again.
The inductive load clamp is built in and is what allows a relay coil or a small motor to be switched without an external diode. The clamp voltage is set by the slew rate control rather than by an external component, which is why the turn off waveform is slower than a bare FET and why the conducted emissions are inside the automotive limits. A circuit that adds its own diode in parallel changes that waveform and the emissions result.
Where this order code fits
It drives lamps, relays, solenoids, small motors and sensor modules in body control units, ADAS sensor housings, display modules and junction boxes, where four protected outputs have to fit in one package with diagnostics the controller can read. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Medical Device Components page.
Questions buyers ask
What is the difference between the A and B order codes? Version A reports an open drain fault flag per channel, version B reports an analogue current sense signal. Same body, same pin count, different diagnostic output, so the choice is made once at the circuit stage.
How much current can one channel carry? The switch is rated by on resistance rather than by a current figure, and the package thermal limit decides. At 1 A per channel with all four on, the 28 pin body is dissipating over a watt and the board copper has to carry it.
Does it need external flyback diodes for relays? No. The inductive load clamp is integrated, and the turn off slew is controlled so the clamp energy is absorbed inside the part.
What is the standby current? Under 500 nA with all channels off, which is what makes the part suitable for a module that stays connected to the battery for months.
How accurate is the current limit? 15 per cent above 500 mA of load and only for overloads greater than 1.5 times the set point. Below that the channel is in foldback and may not flag.
Can the channels be paralleled for a higher current load? Not directly. The two channels will not share current evenly without ballast, and the diagnostics will report the imbalance as a fault. Use a single larger switch instead.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Incoming Inspection Plan page sets out the checks that keep a substitute from failing on the bench.