TPS3899PL31DSER
Product Specifications
TPS3899PL31DSER
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS3899PL31DSER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS3899PL31DSER 3.10 V supervisor with a push-pull reset and programmable delays
The TPS3899PL31DSER is the push-pull active-low member of the TPS3899 family at the 3.10 V threshold option. It draws 125 nA typical, sets its sense delay and its reset delay from two separate capacitors, and drives a reset line without a pull-up resistor in a 6 pin WSON body of 1.50 mm by 1.50 mm.
The 3.10 V threshold is the highest of the three common 3.3 V options in this family and it is the one that needs the most care. On a 3.3 V rail at plus or minus 5 %, the bottom of the supply window is 3.135 V, which is 35 mV above the nominal trip. Add the 2 % threshold window and the trip can sit above the rail's own minimum, so the part asserts reset on a supply that is still inside specification.
Key parameters taken from the SLVSFM0C document
| Supply range | 0.85 V to 6 V on VDD for this output option |
| Falling threshold | 3.10 V nominal, from the fixed table that runs 0.8 V to 5.4 V in 100 mV steps |
| Threshold accuracy | 0.5 % typical, 2 % maximum over minus 40 to plus 125 degrees, which is plus or minus 62 mV at 3.10 V |
| Worst case trip | 3.038 V at the low end and 3.162 V at the high end of that window |
| Hysteresis | 5 % typical, 3 to 8 % window, so the release point sits near 3.255 V |
| Supply current | 125 nA typical, which is the same across the family and does not change with the threshold |
| Output | Push-pull active-low, 0.8 times VDD minimum high at 500 microamp source, 300 mV maximum low at 2 mA sink |
| Sense delay | CTS capacitor, 654666 times capacitance in farads plus 50 microseconds |
| Reset delay | CTR capacitor, 654666 times capacitance in farads plus 80 microseconds |
| Capacitor ceiling | 10 microfarad on each pin, with the discharge condition that the fault must last about a tenth of the delay |
| Separate sense | Yes, so the part can run from one rail and watch another through a divider |
| Power-on reset | Output defined from 700 mV of VDD |
| Body | WSON DSE 6 pin, 1.50 mm by 1.50 mm |
Where 3.10 V does and does not fit
On a 3.3 V rail with a 2 % supply tolerance the window is 3.234 V to 3.366 V, the worst case trip is 3.162 V at the top of its window, and the margin is 72 mV. That works, and it is the case this option is built for: a tightly regulated 3.3 V rail where the supervisor has to catch a failure and not a tolerance.
On a 3.3 V rail with a 5 % tolerance the window is 3.135 V to 3.465 V and the margin to the worst case trip is negative, because 3.162 V is above 3.135 V. A part with a 3.10 V threshold on that rail will assert reset at the bottom of the supply window, which is a false trip that shows up as a product that reboots on a cold morning and passes on the bench.
On a 3.6 V rail the margin is comfortable and the part is a sensible choice. On a 3.3 V rail with a 5 % supply the 3.00 V or 2.90 V member is the correct part, and the difference between them is one character in the order code, which is exactly the mistake an incoming inspection is meant to catch.
Two capacitors, one for the fault and one for the hold
The two delays are independent, which is the feature that separates this part from a plain supervisor. CTS decides how long the fault has to persist before the output asserts. CTR decides how long the output stays asserted after the rail recovers.
| Both open | 50 microseconds to assert and 80 microseconds to release |
| CTS 10 nF | About 7 ms of fault filtering, which removes supply noise and keeps real faults |
| CTS 100 nF | About 66 ms, the setting that also debounces a push-button on the same pin |
| CTR 47 nF | About 31 ms of hold, enough for a reference to settle after a rail recovers |
| CTR 1 microfarad | About 0.65 s of hold, used where a converter has to discharge before a restart |
| Discharge rule | A fault shorter than about a tenth of the programmed delay leaves the capacitor charged and shortens the next delay |
The push-button function comes from the same pin. Because CTS is the sense delay input, pulling it low forces the output to assert after the programmed time, which makes a front panel button and a supply fault look identical to the controller. That is convenient and occasionally undesirable, and the answer in both cases is the same pin with a different capacitor.
Where the PL31 is used
- 3.3 V rails from a tightly regulated supply with a 2 % or better window
- 3.6 V and 4.2 V rails where the trip has to sit high in the band
- Boards where the reset drives an enable pin directly and a pull-up is not wanted
- Products with a front panel button that has to reset the controller through the same supervisor
- Battery and portable equipment where 125 nA of standing current is the budget
The applications the vendor prints include electricity meters, building automation, body control modules, data centre and enterprise computing, notebooks, servers, smart phones, portable equipment, solid state drives and set top boxes. Most of those use the 3.0 V option, and the 3.1 V option is the variant for the tighter supply.
Order code, marking and reel
| TPS3899PL31DSER | Active, production, WSON DSE 6 pin, 3000 pieces on a large reel, marking LH |
| Lead finish | NIPDAU, moisture level 1 at 260 degrees with unlimited floor life |
| Same threshold, other outputs | TPS3899DL31DSER open-drain and TPS3899PH31DSE push-pull active-high |
| Lower thresholds | TPS3899PL30DSER at 3.00 V and TPS3899PL29DSER at 2.90 V, both one reel and one land pattern away |
| Marking note | Two characters on the body, so LH against LM is the only visible difference from the 3.00 V member |
Sourcing notes for this line
The 3.10 V option is the one that most often arrives on a build by mistake when the bill of materials says 3.3 V supervisor without a threshold. The power management cross reference lists the three 3.3 V options side by side and states the supply tolerance each one needs, which is the check that prevents the mistake.
Where a customer's rail tolerance is not documented, the safe route is the 3.00 V member and a note in the inspection plan, because the false trip at minus 5 % is a field failure rather than a line failure. The incoming inspection plan page sets out how the marking and the reel label are checked against the order code.
The same family is also worth consolidating across a product line, because the three output topologies and the whole 0.8 V to 5.4 V range share one land pattern. The BOM consolidation page covers how that consolidation is done without losing the threshold control.
Questions buyers ask about this part
Is 3.10 V too close to a 3.3 V rail? On a 5 % supply it is. On a 2 % supply the margin is 72 mV and the part works. The supply window decides, not the nominal.
Can the output drive a load switch gate? At 500 microamp of source current it drives a logic pin. A power MOSFET gate needs a buffer.
Do both capacitors have to be fitted? No. Either pin can be left open, and the part then uses the 50 or 80 microsecond default on that path.
What is the current draw with the output asserted? The 125 nA figure is the quiescent current. The load current through the output pin adds to it while the reset is asserted.