The TPS3899PL31DSER from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS3899PL31DSER 3.10 V supervisor with a push-pull reset and programmable delays

The TPS3899PL31DSER is the push-pull active-low member of the TPS3899 family at the 3.10 V threshold option. It draws 125 nA typical, sets its sense delay and its reset delay from two separate capacitors, and drives a reset line without a pull-up resistor in a 6 pin WSON body of 1.50 mm by 1.50 mm.

The 3.10 V threshold is the highest of the three common 3.3 V options in this family and it is the one that needs the most care. On a 3.3 V rail at plus or minus 5 %, the bottom of the supply window is 3.135 V, which is 35 mV above the nominal trip. Add the 2 % threshold window and the trip can sit above the rail's own minimum, so the part asserts reset on a supply that is still inside specification.

Key parameters taken from the SLVSFM0C document

Supply range0.85 V to 6 V on VDD for this output option
Falling threshold3.10 V nominal, from the fixed table that runs 0.8 V to 5.4 V in 100 mV steps
Threshold accuracy0.5 % typical, 2 % maximum over minus 40 to plus 125 degrees, which is plus or minus 62 mV at 3.10 V
Worst case trip3.038 V at the low end and 3.162 V at the high end of that window
Hysteresis5 % typical, 3 to 8 % window, so the release point sits near 3.255 V
Supply current125 nA typical, which is the same across the family and does not change with the threshold
OutputPush-pull active-low, 0.8 times VDD minimum high at 500 microamp source, 300 mV maximum low at 2 mA sink
Sense delayCTS capacitor, 654666 times capacitance in farads plus 50 microseconds
Reset delayCTR capacitor, 654666 times capacitance in farads plus 80 microseconds
Capacitor ceiling10 microfarad on each pin, with the discharge condition that the fault must last about a tenth of the delay
Separate senseYes, so the part can run from one rail and watch another through a divider
Power-on resetOutput defined from 700 mV of VDD
BodyWSON DSE 6 pin, 1.50 mm by 1.50 mm

Where 3.10 V does and does not fit

On a 3.3 V rail with a 2 % supply tolerance the window is 3.234 V to 3.366 V, the worst case trip is 3.162 V at the top of its window, and the margin is 72 mV. That works, and it is the case this option is built for: a tightly regulated 3.3 V rail where the supervisor has to catch a failure and not a tolerance.

On a 3.3 V rail with a 5 % tolerance the window is 3.135 V to 3.465 V and the margin to the worst case trip is negative, because 3.162 V is above 3.135 V. A part with a 3.10 V threshold on that rail will assert reset at the bottom of the supply window, which is a false trip that shows up as a product that reboots on a cold morning and passes on the bench.

On a 3.6 V rail the margin is comfortable and the part is a sensible choice. On a 3.3 V rail with a 5 % supply the 3.00 V or 2.90 V member is the correct part, and the difference between them is one character in the order code, which is exactly the mistake an incoming inspection is meant to catch.

Two capacitors, one for the fault and one for the hold

The two delays are independent, which is the feature that separates this part from a plain supervisor. CTS decides how long the fault has to persist before the output asserts. CTR decides how long the output stays asserted after the rail recovers.

Both open50 microseconds to assert and 80 microseconds to release
CTS 10 nFAbout 7 ms of fault filtering, which removes supply noise and keeps real faults
CTS 100 nFAbout 66 ms, the setting that also debounces a push-button on the same pin
CTR 47 nFAbout 31 ms of hold, enough for a reference to settle after a rail recovers
CTR 1 microfaradAbout 0.65 s of hold, used where a converter has to discharge before a restart
Discharge ruleA fault shorter than about a tenth of the programmed delay leaves the capacitor charged and shortens the next delay

The push-button function comes from the same pin. Because CTS is the sense delay input, pulling it low forces the output to assert after the programmed time, which makes a front panel button and a supply fault look identical to the controller. That is convenient and occasionally undesirable, and the answer in both cases is the same pin with a different capacitor.

Where the PL31 is used

  • 3.3 V rails from a tightly regulated supply with a 2 % or better window
  • 3.6 V and 4.2 V rails where the trip has to sit high in the band
  • Boards where the reset drives an enable pin directly and a pull-up is not wanted
  • Products with a front panel button that has to reset the controller through the same supervisor
  • Battery and portable equipment where 125 nA of standing current is the budget

The applications the vendor prints include electricity meters, building automation, body control modules, data centre and enterprise computing, notebooks, servers, smart phones, portable equipment, solid state drives and set top boxes. Most of those use the 3.0 V option, and the 3.1 V option is the variant for the tighter supply.

Order code, marking and reel

TPS3899PL31DSERActive, production, WSON DSE 6 pin, 3000 pieces on a large reel, marking LH
Lead finishNIPDAU, moisture level 1 at 260 degrees with unlimited floor life
Same threshold, other outputsTPS3899DL31DSER open-drain and TPS3899PH31DSE push-pull active-high
Lower thresholdsTPS3899PL30DSER at 3.00 V and TPS3899PL29DSER at 2.90 V, both one reel and one land pattern away
Marking noteTwo characters on the body, so LH against LM is the only visible difference from the 3.00 V member

Sourcing notes for this line

The 3.10 V option is the one that most often arrives on a build by mistake when the bill of materials says 3.3 V supervisor without a threshold. The power management cross reference lists the three 3.3 V options side by side and states the supply tolerance each one needs, which is the check that prevents the mistake.

Where a customer's rail tolerance is not documented, the safe route is the 3.00 V member and a note in the inspection plan, because the false trip at minus 5 % is a field failure rather than a line failure. The incoming inspection plan page sets out how the marking and the reel label are checked against the order code.

The same family is also worth consolidating across a product line, because the three output topologies and the whole 0.8 V to 5.4 V range share one land pattern. The BOM consolidation page covers how that consolidation is done without losing the threshold control.

Questions buyers ask about this part

Is 3.10 V too close to a 3.3 V rail? On a 5 % supply it is. On a 2 % supply the margin is 72 mV and the part works. The supply window decides, not the nominal.

Can the output drive a load switch gate? At 500 microamp of source current it drives a logic pin. A power MOSFET gate needs a buffer.

Do both capacitors have to be fitted? No. Either pin can be left open, and the part then uses the 50 or 80 microsecond default on that path.

What is the current draw with the output asserted? The 125 nA figure is the quiescent current. The load current through the output pin adds to it while the reset is asserted.