Contact Us

TPS3702CX50DDCR

Brand: Texas Instruments
Texas Instruments TPS3702CX50DDCR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS3702CX50DDCR — Power Management & Signal Chain | Superb Automation

TPS3702CX50DDCR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS3702CX50DDCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS3702CX50DDCR: a 5 V window monitor with plus or minus 5 or plus or minus 10 per cent thresholds selected by one pin

TPS3702CX50DDCR is an overvoltage and undervoltage window detector with two open drain outputs and fixed thresholds set inside the part in a SOT-23 THIN (DDC) body of 6 pins. It watches one rail between 1 V and 5 V against a pair of fixed thresholds and drives two separate open drain outputs, one for an overvoltage event and one for an undervoltage event. On this 5.0 V member the undervoltage point is 4.80 V and the overvoltage point is 5.20 V with the select pin high, and 4.55 V and 5.45 V with it low, so the same order code covers a 5 per cent and a 10 per cent window. Threshold accuracy is plus or minus 0.9 per cent over minus 40 C to 125 C, supply current is 7 microamp, and the sense pin is separate from the supply pin.

Order code and package

TPS3702CX50DDCRSOT-23 thin body of 6 pins, 3000 pieces on a large reel, nickel palladium finish, moisture level 2 at 260 C with one year of floor life, marking ZAQO, active status in the package addendum
TPS3702CX50DDCR.Athe second assembly row of the same string, 250 pieces on a small reel and a different marking, which is what a pilot build receives
TPS3702CX33 and AX33the 3.3 V members with the same two window options, thresholds 3.17 V and 3.60 V for the 10 per cent window and 3.23 V and 3.50 V for the 5 per cent window
TPS3702CX18 and AX18the 1.8 V members, and the CX12 and CX10 members cover the 1.2 V and 1.0 V rails
Select pinlow for the wider window and high for the narrower one, so the window is a board strap rather than a different order code
Outputstwo open drain pins, one per direction, which lets a system distinguish a sag from a surge instead of seeing one reset

Electrical parameters that decide the application

Supply voltage2 V to 18 V on the supply pin, which is a much wider range than the rail being monitored and lets the part be powered from a 12 V bus
Monitored voltage1 V to 5 V on the sense pin, separate from the supply so a low rail can be watched by a part powered from a higher one
Thresholds on this member4.55 V and 5.45 V with the select pin low, 4.80 V and 5.20 V with it high, both against a 5.0 V nominal rail
Threshold accuracyplus or minus 0.9 per cent over minus 40 C to 125 C, with a 0.25 per cent typical figure at 25 C
Hysteresis0.55 per cent or 1.0 per cent of the nominal trip point depending on the member, which is what stops a rail sitting at a threshold from chattering the output
Supply current6 microamp typical at a 2 V supply and 7 microamp at 5 V, with a 10 microamp maximum, which is low enough to leave the monitor powered from the rail it watches
Outputsopen drain, pulling to 0.25 V at 15 microamp and to lower values at higher sink currents, with the pull-up free to sit above the supply
Glitch immunityinternal filtering on the sense path, which is what keeps a switching transient from being reported as a fault
Power-on resetthe outputs are defined from a supply of 0.8 V, so the monitor reports a fault before the rail is valid
Lockoutan internal undervoltage lockout on the supply, so the outputs are held in the fault state when the monitor itself is under powered
Response timespecified in the timing table rather than as an instant trip, so the sense path has to be checked against the fastest event the system cares about
Temperatureminus 40 C to 125 C, the same window as the rest of the family

Released threshold options in this family

TPS3702CX50DDCRthe 5.0 V window monitor covered by this order code, thresholds 4.55 V and 5.45 V with the select pin low and 4.80 V and 5.20 V with it high
TPS3702CX33 and AX33the 3.3 V members, 3.17 V and 3.60 V for the 10 per cent window and 3.23 V and 3.50 V for the 5 per cent window
TPS3702CX18 and AX18the 1.8 V members, with the CX12 and CX10 covering 1.2 V and 1.0 V rails
Select pinone strap chooses the window, so the same order code covers both tolerances
Outputstwo independent open drain pins, one per direction, which lets a system tell a sag from a surge
Supply pin2 V to 18 V, separate from the sense pin, so a low rail can be watched by a part powered from a higher bus
Accuracyplus or minus 0.9 per cent over temperature and 0.25 per cent typical, with no external divider to add to it

Points to check before this part goes on a BOM

Two thresholds and one pin is the whole point. The narrow window catches a rail that has drifted out of specification, and the wide window catches a rail that has failed. A board can populate the strap for one and change it later without changing the order code.

The supply pin and the sense pin are separate on purpose. That is what allows a 1.0 V core rail to be monitored by a part powered from 3.3 V, and it is also what allows the monitor to keep working when the rail it watches collapses.

The thresholds are fixed, so there is no divider tolerance. The part uses an internal divider with 0.25 per cent typical accuracy, which is tighter than any external pair a board would fit. The trade is that a rail at a non standard nominal value needs a different member rather than a different resistor.

The hysteresis is a percentage of the trip point, not a voltage. At 5 V and 0.55 per cent that is about 27 mV, so a rail that recovers by less than that stays in the fault state. A supply with a slow recovery needs the wider window instead of a bigger capacitor.

The outputs are open drain and independent. A system that ties them together loses the ability to tell a sag from a surge, which is usually the first thing a field return needs to know.

The body is the thin SOT-23. 6 pins on a 2.9 mm by 1.6 mm footprint, which is what makes a window monitor practical on a dense board next to the rail it watches.

Why a window monitor is used instead of two detectors

Two single detectors need two dividers, two parts and two placements, and their tolerances do not match. A window monitor puts both thresholds on one die with one reference, so the width of the window is accurate rather than the sum of two resistor pairs.

The separate outputs are the second reason. A processor can be reset on an undervoltage event and a supply can be latched off on an overvoltage event, which is a different response to each direction and is not possible with one combined output.

Where the 5 V member is used

A 5 V intermediate bus feeding an analog front end, a sensor and a radio is the usual place. The 5 per cent window matches what those loads tolerate, and the 10 per cent window is used when the load has its own regulator behind the bus.

Because the supply pin reaches 18 V, the same part can be powered from a 12 V rail while it watches the 5 V bus, which removes a small regulator from the board.

Where this order code fits

a 5 V intermediate bus in an instrument, a base station card or a medical monitor where a sag and a surge need different responses Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Incoming Inspection Plan page.

Questions buyers ask

How do I select the 5 per cent window? Pull the select pin high. With it low the part uses the 10 per cent window, which on this member is 4.55 V and 5.45 V instead of 4.80 V and 5.20 V.

Can it monitor a 1.2 V rail from a 12 V supply? The supply pin reaches 18 V and the sense pin is separate, so yes, as long as the member is the 1.2 V one. This 5 V member has fixed thresholds and cannot be moved to a 1.2 V rail.

Are the outputs independent? Yes, one for overvoltage and one for undervoltage, both open drain, so the system can respond differently to each direction.

Does it need external resistors? No. The thresholds are set inside the part, which is what gives the 0.25 per cent typical accuracy. A rail at a non standard nominal value needs a different member of the family.

What supply current does it draw? 6 microamp typical at 2 V and 7 microamp at 5 V, with a 10 microamp maximum, so it can be left powered from the rail it monitors.

What packing does the DDC suffix arrive in? 3000 pieces on a large reel at moisture level 2 with one year of floor life, while the .A row of the same string is a 250 piece small reel with a different marking.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Medical Device Components page sets out the checks that keep a substitute from failing on the bench.