TPS274C65ASRHAR

Brand: Texas Instruments
Texas Instruments TPS274C65ASRHAR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS274C65ASRHAR — Power Management & Signal Chain | Superb Automation

TPS274C65ASRHAR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS274C65ASRHAR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS274C65ASRHAR quad high side switch with a 2.2 A limit ceiling

The TPS274C65ASRHAR is the base AS row of the four channel high side switch family, in the same 40 pin 6 mm by 6 mm VQFN as the H rows. Four channels, 72 milliohm each, SPI control, digital current readback and a diagnostics set that covers open load in both states and shorts to either rail. The AS row sets the current limit window at 250 mA to 2.2 A, which is the row to pick when the load population is known and a 2.45 A ceiling would leave a fault undetected for too long.

The family logic is worth following before an order is placed. The rows differ in the current limit ceiling and in a handful of pin functions, not in the body or the reel. That means a card built around the AS row can be reworked to an H row if a load grows, and a card built around an H row cannot simply drop to the AS row without checking that every channel still fits under 2.2 A.

Key parameters taken from the TPS274C65 document

ChannelsFour, independent, each with its own limit and diagnostics
On resistance72 milliohm per channel
Steady load500 mA to 2 A DC per channel in the reference conditions
Current limitAdjustable, 250 mA to 2.2 A on this row
InrushConfigurable period at a higher second limit for capacitive loads and lamps
InterfaceSPI, with control and diagnostics on the same link
Current senseIntegrated analog to digital conversion, reported as a digital value
DiagnosticsOn and off state open load, short to supply, short to ground, thermal warning
Inductive loadsIntegrated clamp for demagnetisation, above 65 V in the reference circuit
ProtectionCurrent limit, thermal shutdown, short to ground, configurable fault handling
PackageVQFN RHA, 40 pins, 6 mm by 6 mm, 0.5 mm pitch
TemperatureMinus 40 to plus 125 degrees, as printed in the orderable addendum
Carrier2500 pieces on a large reel, moisture level 2 at 260 degrees

The document prints the pin functions as a table that covers the AS, ASH and BS versions together, with a number of pins marked do not connect on some versions. That is the detail that decides whether a rework from one row to another is a straight swap.

Where the numbers matter in a real build

Two point two amps sounds generous next to a 500 mA sensor load and tight next to a contactor. The useful way to read the number is against the load's own tolerance and its temperature coefficient. A solenoid rated at 2 A at 20 degrees draws more when the coil warms up, and a limit set at 2.2 A leaves 10 per cent. On a card that has to work in a cabinet at 55 degrees, that margin disappears, and the honest fix is either a higher row or a load with a lower steady current.

The diagnostics are the reason this family exists. A four channel card without per channel current readback needs four sense resistors, four amplifiers and four ADC channels, which is more board area and more calibration than the switch itself. The integrated conversion moves that work into the part and reports it over the same SPI link that sets the outputs. The cost is that a failure of the SPI link takes the diagnostics with it, while the outputs keep switching on their last written state.

The third number is the 72 milliohm, which at 2 A gives 288 milliwatt per channel. Four loaded channels in a sealed enclosure put more than a watt into a 6 mm body, and the thermal information section ties the permissible value to the copper area under the pad. A two layer board with a modest pour is not the same thermal environment as the reference board, and the junction temperature follows from that difference.

  • The limit ceiling against the warm load current, not the cold one printed on the label.
  • The thermal copper area and via count under the pad, which the thermal section conditions depend on.
  • The inrush limit and period, set in registers and therefore easy to leave at a default that trips a lamp.
  • The off state open load threshold, since a broken wire on an off channel is the most common field failure.
  • The SPI isolation barrier, which is a separate component on the card.
  • The moisture level record, because a leadless 0.5 mm pitch body is sensitive to the reflow profile.

Which projects this part fits

The document aims the family at industrial control output modules that drive solenoids, lamps, contactors, valve pilots and resistive heaters. The AS row suits cards where the loads are known, the steady currents are below 2 A and the fault current has to be caught early.

Questions that come up before a purchase order is released

Why choose the AS row rather than the ASH row?

The ASH row raises the ceiling to 2.45 A. Where a 2 A load has to trip quickly on a short, the lower ceiling catches the fault sooner and limits the energy that reaches the wiring.

Can the four channels be paralleled for a 6 A load?

The document does not present the part as a parallelable switch. Each channel has its own limit and its own diagnostics, and paralleling them would defeat the per channel fault isolation the family is built for.

Does the part need an external flyback diode on a solenoid?

It carries an integrated demagnetisation clamp. A load whose stored energy exceeds what the clamp can absorb still needs an external device, and the clamp current is a limit worth reading in the electrical characteristics.

What does the ADC measure, current or voltage?

Load current, converted inside the part and reported over SPI. The value is what makes predictive maintenance possible without an external sense resistor.

How SUPERB handles this line

A card with four smart switches usually carries the connectors, the clamp parts and the isolated SPI devices as well, and the whole set has to be on the line at the same time. Our power management cross reference covers the switch families this part is compared against. The one stop BOM sourcing page describes how a mixed bill is quoted, and our incoming inspection plan sets out the checks a reel goes through before it reaches the line.