Contact Us

TPS259530DSGR

Brand: Texas Instruments
Texas Instruments TPS259530DSGR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS259530DSGR — Power Management & Signal Chain | Superb Automation

TPS259530DSGR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS259530DSGR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS259530DSGR: an 18 V 4 A eFuse with a 5.7 V overvoltage clamp in a 2 mm by 2 mm body

TPS259530DSGR is an integrated hot swap device that sits between a backplane and a load, limiting inrush, holding the current at a set level and cutting off a fault in microseconds in a WSON (DSG) body of 8 pins. It works from 2.7 V to 18 V, carries 4 A through a 34 milliohm switch, clamps at 5.7 V within about 5 microseconds, and sets the current limit anywhere from 0.5 A to 4 A with one resistor. Thermal shutdown latches off on this variant rather than retrying.

Order code and package

TPS259530DSGRWSON (DSG) body, 8 pins, 2.00 mm by 2.00 mm, 3000 pieces on a large reel, nickel palladium gold finish, moisture level 2 at 260 C for one year, minus 40 C to 125 C
TPS259530DSGTthe same body on a 250 piece small reel, the string a pilot build orders
TPS259531DSGRthe same 5.7 V clamp with auto retry after thermal shutdown instead of latch off, which is the difference that matters in an unattended box
TPS259533DSGRthe 5.7 V clamp with an active low enable and auto retry, for a system that drives the enable from an open drain signal
TPS259535DSGRthe 5.7 V clamp with quick output discharge, so the load rail collapses when the device turns off
TPS259520DSGRthe 3.8 V clamp member of the same family, for a 3.3 V rail that must not see a 5 V transient

Electrical parameters that decide the application

Input voltage2.7 V to 18 V operating with a 20 V absolute maximum, which covers a 12 V bus with load dump margin
Output current4 A continuous through the internal switch
Switch resistance34 milliohm typical, and 53 milliohm maximum over the minus 40 C to 85 C junction range
Overvoltage clamp5.7 V typical on this variant, with a response time of about 5 microseconds and no external components
Current limit0.5 A to 4 A set by one resistor on the ILM pin, with plus or minus 7.5 per cent accuracy
Quiescent current175 microamp typical and 250 microamp maximum with the device enabled
Enable threshold1.2 V typical on the EN/UVLO pin, so a divider sets the undervoltage lockout at any level inside the input range
Slew controla capacitor on the dVdt pin sets the output ramp, which is how the inrush into a large load capacitor is kept inside the current limit
Fault outputan open drain FLT pin that pulls low on a fault and can be wired to a controller or a second device
Thermal behaviourovertemperature shutdown that latches off on this variant, so the load stays off until the enable is cycled
Standardsrecognised to UL 2367 under file E169910 and certified to IEC 62368-1, including the single point failure test
Diagnosticsthe ILM pin is monitored for an open and a short, which is how the device reports that the current limit has been lost

Family variants and how they differ

TPS259520 and TPS259521the 3.8 V clamp pair, latch off and auto retry, for a 3.3 V rail
TPS259530, 531 and 533the 5.7 V clamp members, differing in latch off, auto retry and enable polarity
TPS259540 and TPS259541the 13.7 V clamp pair, for a 12 V rail that has to survive a transient
TPS259570 and TPS259571no overvoltage clamp, for a rail where the supply is already regulated and only the current has to be limited
TPS259573a programmable overvoltage lockout instead of a fixed clamp, with auto retry and an active low enable
TPS259525 and TPS259535the members with quick output discharge, which pull the load rail down when the switch opens

Points to check before this part goes on a BOM

The clamp voltage has to match the rail. A 5.7 V clamp on a 5 V rail leaves only 0.7 V of headroom, and a 3.8 V clamp on a 3.3 V rail leaves 0.5 V, so the choice follows the tolerance of the supply rather than the nominal voltage.

Latch off and auto retry are not interchangeable. A latched device stays off after a thermal fault until the enable is cycled, which is right for a box that needs an operator, and wrong for a remote unit that has nobody to cycle it.

The current limit is set by a resistor, and the resistor tolerance is part of the accuracy. The device holds plus or minus 7.5 per cent, and the resistor adds its own tolerance on top of that.

The dVdt capacitor is what keeps a hot plug inside the limit. Without it the inrush into the load capacitor is limited only by the current loop, and the rail can still dip below the undervoltage lockout of the load.

The standards matter in a safety review. UL 2367 and IEC 62368-1 are both named in the document, including the single point failure test, which is what a safety engineer will ask for first.

What the eFuse replaces

A discrete solution needs a pass FET, a sense resistor, a comparator, a gate driver and a handful of passive parts, and the current limit accuracy depends on the sense resistor. The eFuse puts all of it in a 2 mm by 2 mm body and holds the limit to plus or minus 7.5 per cent without a sense resistor.

The other half of the job is the transient. A 5.7 V clamp that reacts in 5 microseconds catches a surge that a fuse would pass through, and the fault pin tells the controller what happened instead of leaving it to guess from a dead rail.

The second decision is the resistor on the ILM pin. The limit is linear in that resistor, so a board that starts at 2 A and later needs 3 A changes one component. The catch is that the same pin reports the load current as a voltage, and the sense path has to be read with the tolerance of the resistor in mind rather than treated as a calibrated measurement.

The third is the enable divider. On the 530 the EN/UVLO pin both enables the device and sets the undervoltage lockout, with a 1.2 V threshold and a small hysteresis. A divider that puts the turn on point at 4.5 V on a 5 V rail keeps the card from drawing current while the backplane is still ramping, which is what a hot swap slot needs.

The faults the device cannot fix are the ones it reports. A shorted load, an open sense resistor and a thermal event all pull the fault pin low, and what the system does with that signal is outside the device. A card that ignores the pin will simply be off with no record of why.

Where this order code fits

It fits a 5 V or 12 V backplane card, a hot swap bay or a remote unit, where a card has to be inserted into a live bus and a fault must not take the bus down. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Incoming Inspection Plan page.

Questions buyers ask

What is the difference between the 530 and the 531? The 530 latches off after a thermal shutdown and the 531 retries automatically. The electrical behaviour is otherwise the same, and the choice follows whether anybody is present to cycle the enable.

Can the current limit be set below 0.5 A? No. The range starts at 0.5 A and runs to 4 A, and below that the fixed 34 milliohm switch and the accuracy of the limit make the device the wrong choice.

Does it protect against overvoltage? Yes. This variant clamps at 5.7 V typical with a response time of about 5 microseconds, and the clamp needs no external components.

Is it certified for a safety review? Yes. The document names UL 2367 recognition under file E169910 and IEC 62368-1 certification, including the single point failure test.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.