TPS23754PWPR
Product Specifications
TPS23754PWPR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS23754PWPR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS23754PWPR: IEEE 802.3at PoE interface and current mode converter controller
TPS23754PWPR is a combined powered device interface and current mode DC to DC controller in a HTSSOP body of 20 pins. It handles detection, classification and the hotswap MOSFET for a Power over Ethernet load, then runs the converter that feeds the load from the PoE rail.
Order code and package
| Order code | TPS23754PWPR, PWP package, HTSSOP twenty lead |
| Standard | IEEE 802.3at Type 2 powered device, with the extended hardware classification that high power midspans use |
| Converter start | 15 V on this part, 9 V on the TPS23756 |
| Gate drives | Two complementary drivers with programmable dead time for an active clamp forward |
| Variant | The TPS23754-1 replaces the PPD pin with a no connect, so the adapter priority function is not available |
Electrical parameters that decide the application
| Maximum duty cycle | 78 percent typical, 76 percent minimum, 80 percent maximum at the control pin high |
| Hotswap MOSFET | Internal, with the current sense input on the PPD and RTN pins |
| Classification | A resistor from CLS to VSS sets the class current with 2.5 V applied during classification |
| Detection | A 24.9 kOhm resistor from DEN to VDD provides the signature |
| Frequency | Set by a resistor from FRS to ARTN |
| Under voltage | Converter start around 9 V with a hysteresis window in the 8.7 V to 9.3 V region |
| Continuous load | IEEE 802.3at permits 600 mA continuous at the powered device input |
Family variants and how they differ
| TPS23756 | Same interface with a 9 V converter start, for a converter that must run from a lower rail |
| TPS23754-1 | Same part with the PPD pin removed and the adapter priority function dropped |
| TPS23751 | Interface only, no converter controller, for a system that has its own DC to DC |
| TPS23753A | Lower power member for 802.3af loads |
| TPS2595 | eFuse for the non PoE case where a rail needs a limit but not a detection signature |
Points to check before this part goes on a BOM
The interface and the converter share one package because a powered device needs both, and the order in which they are specified matters. Detection comes first: the 24.9 kOhm signature resistor tells the sourcing equipment that a valid device is present, and a wrong value means the port is never powered at all. The signature is checked before classification and before any converter activity, so a board that draws current too early fails detection rather than failing later.
Classification with the extended hardware scheme is what separates this part from the older 802.3af controllers. A Type 2 source uses two classification events, and the resistor from CLS to VSS sets the class current with 2.5 V applied across it during each event. A class 4 load needs the two event scheme to be recognised, and a device that presents only the first event is powered as a Type 1 load at 13 W, which is enough to boot a product and not enough to run it.
The hotswap MOSFET and its sense resistor are inside the current path, so the 600 mA continuous limit is a thermal and a sensing limit at once. The sense voltage across the resistor sets the current limit, and the resistor tolerance directly sets how much power the load can draw before the interface interrupts. A one percent resistor is the usual choice, and the trace from the sense pin to the resistor has to be a Kelvin connection or the limit moves with the copper.
The 78 percent maximum duty cycle is a limit that decides the converter topology. An active clamp forward running from a 37 V to 57 V PoE rail needs a turns ratio that produces the output at the minimum rail with the duty below the maximum, and at the maximum rail the duty falls and the clamp does its work. A flyback could exceed 78 percent, and this controller will not let it, which is why the datasheet pairs it with a forward topology.
Two complementary gate drivers with programmable dead time are what make an active clamp forward practical. The main switch and the clamp switch must never conduct together, and the dead time has to be long enough for the switch node to settle and short enough that the clamp capacitor does its job. Setting it from a resistor rather than from a fixed internal value lets the same part cover different switch sizes and different clamp capacitors, and the dead time has to be checked on the bench at the extremes of load.
Start up at 15 V on this part, against 9 V on the TPS23756, is a choice about what the converter does during a brownout. A 15 V start means the converter does not try to run on a collapsing rail, which avoids a hiccup mode where the output droops and the load resets. A 9 V start keeps the converter running longer during a transient, at the cost of deeper discharge of the input capacitance. The two parts are not interchangeable without changing the input capacitor.
The adapter priority function, present on this part and absent on the -1, decides which source feeds the load when an adapter and PoE are both present. The PPD pin enables classification when the adapter is active and selects the higher of the two inputs. A product that must prefer the adapter needs this order code, and a product that always prefers PoE can use the -1. Getting this wrong means the load runs from the wrong source and the port is classified while the adapter is supplying power.
The twenty lead HTSSOP has an exposed pad, and that pad is the thermal path for both the hotswap MOSFET and the gate drivers. The datasheet thermal table gives the junction to ambient resistance for the package on the JEDEC board, and a real board with a small pad or few vias will run hotter. The interface carries the full load current during normal operation, so the pad is not optional and the via count under it belongs in the fabrication drawing.
The 600 mA continuous figure that IEEE 802.3at allows at the powered device input is not the same as the 25.5 W at the source. The difference is the cable loss, which at 100 m of category 5 cable is a few watts, and the interface has to survive the resulting current while the converter runs. That is why the internal MOSFET and the sense resistor carry a current limit well above 600 mA: the limit is there for a fault, not for the normal load, and setting it too close to 600 mA will trip on a legitimate inrush at power up. The sense resistor value is chosen against the converter's peak input current, not against the class current.
Where this order code fits
It is the front end for a PoE powered product on the load side: an IP camera, a wireless access point, a signage panel or an industrial sensor that takes its power from the Ethernet cable and needs classification above 13 W. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the One Stop BOM Sourcing page.
Questions buyers ask
Does it include the hotswap MOSFET? Yes, the interface MOSFET and its sensing are internal, and the current limit is set by the external sense resistor.
What sets the PoE class? A resistor from CLS to VSS sets the classification current, and the source reads it during the classification events.
Can it run a flyback? The 78 percent maximum duty makes a forward topology the intended partner; a flyback board needs a different controller.
What is the difference to the TPS23756? The 23756 starts its converter at 9 V instead of 15 V, which changes the brownout behaviour and the input capacitance requirement.
Does it need an external signature resistor? Yes, 24.9 kOhm from DEN to VDD provides the detection signature, and the part does not integrate it.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.